A method to correct myocardial SPECT with Tc-99m compounds for scatter and attenuation without transmission

被引:0
作者
Kupferschlager, J [1 ]
Muller, B [1 ]
Schulz, G [1 ]
Kaiser, HJ [1 ]
Wagenknecht, G [1 ]
Bares, R [1 ]
Bull, U [1 ]
机构
[1] UNIV AACHEN,RHEIN WESTFAL TH KLINIKUM,KLIN NUKL MED,D-5100 AACHEN,GERMANY
关键词
Tc-99m MIBI SPECT; attenuation correction; scatter correction;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: A new strategy is introduced for a double-head gamma-camera to calculate and to correct for attenuation distribution from countrates of backscattered radiation of Tc-99m in the human thorax/myocardium set ting. The intention was to gain segmented and calibrated images of distribution employing the structures of lungs and other tissues; so that attenuation may be subsequently corrected by the method of Chang. Methods: Acquisition was done simultanously in three energy windows for Tc-99m to receive both emitted and scattered radiation. The acquired projections were used to calculate the attenuation distribution and to execute a scattercorrection by the method of Ogawa et. al. By measuring phantoms and evaluating a set of patient studies, quality for both of the approaches towards attenuated distribution and the quality of attenuation correction was tested and an optimal setting for parameters involved was selected. Results: The procedure adequately approaches the correction for both emitted and scattered radiation in SPECT, as experienced in phantom and patient studies. Clinical usefulness was preliminary documented in selected cases. In normal perfusion, distribution was more homogenous. Perfusion defects appeared more definitive Problems occurred in high adjacent non-target activity (e.g., in the gallbladder) and with low countrate statistics. Conclusion: Myocardial Tc-99m MIBI SPECT may be effectively corrected for both attenuation and scatter without an additional transmission device.
引用
收藏
页码:56 / 64
页数:9
相关论文
共 16 条
[1]  
[Anonymous], ATOMIC NUCLEUS
[2]  
BIEDERMANN M, 1994, NUKLEARMED-NUCL MED, V33, P8
[3]  
BULL U, 1983, ROFO FORTSCHR RONTG, V138, P391
[5]  
CHANG W, 1984, J NUCL MED, V25, P788
[6]   Simultaneous transmission emission myocardial perfusion tomography diagnostic accuracy of attenuatian-corrected Tc-99m-sestamibi single-photon emission computed tomography [J].
Ficaro, EP ;
Fessler, JA ;
Shreve, PD ;
Kritzman, JN ;
Rose, PA ;
Corbett, JR .
CIRCULATION, 1996, 93 (03) :463-473
[7]  
GALT JR, 1992, J NUCL MED, V33, P2232
[8]  
Knesewitsch P, 1996, NUKLEARMED, V35, P78
[9]  
KUPFERSCHLAGER J, 1995, THESIS RWTH AACHEN
[10]  
LUIG H, 1996, NUKLEARMEDIZINER, V19, P87