A Method for Creating Artificial Thrombi In Vitro Using a Rotating Mechanical Surface

被引:2
作者
Jessen, Staci L. [1 ]
Masse, Andrew M. [2 ]
Carpenter, Malory D. [2 ]
Clubb, Fred J., Jr. [1 ,2 ,3 ]
Weeks, Brad R. [2 ,3 ]
机构
[1] Texas A&M Univ, Dept Biomed Engn, College Stn, TX USA
[2] Texas A&M Univ, Coll Vet Med, College Stn, TX 77843 USA
[3] Texas A&M Univ, Dept Vet Pathobiol, College Stn, TX USA
关键词
Thrombosis; VADs; Thrombi; Plasma thrombi; VENTRICULAR ASSIST DEVICES; THROMBOEMBOLIC COMPLICATIONS; PLATELET-ADHESION; MOCK CIRCULATION; PUMP THROMBUS; HEART; MANAGEMENT; PROTOCOL; BLOOD; COAGULATION;
D O I
10.1097/MAT.0000000000000332
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Thromboembolism is a common concern in ventricular assist device (VAD) therapy. Precise VAD response to pass-through thromboembolism needs to be studied in a controlled in vitro setting where specific pump parameters (i.e., power consumption, flow rates, impeller RPM) can be monitored while various types of thrombi are introduced. In this article, we describe a method for creating standardized fibrin thrombi that could be introduced into a mock circulatory loop for testing VAD response to thromboembolism. Donor equine blood collected using a sodium citrate was allowed to clot by adding calcium chloride (CaCl2) while a rotating component applied shear forces to the blood. This rotating force was applied at various speeds and at various distances into the blood. Resulting clots showed similar microscopic features to thrombi taken from explanted clinical VADs. Higher RPM of the rotating component and smaller clearances between the rotating component and the blood created clots that closely resembled ante-explant clots found within VADs in vivo. This method is an effective way to create artificial fibrin clots for use in in vitro experiments to test thromboembolism in VADs.
引用
收藏
页码:252 / 260
页数:9
相关论文
共 30 条
[1]   Thrombosis and failure of a Heart Mate II Device in the absence of alarms [J].
Bashir, Jamil ;
Cheung, Anson ;
Kaan, AnneMarie ;
Kearns, Mark ;
Ibey, Andrew ;
Ignaszewski, Andrew .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2011, 30 (10) :1197-1199
[2]   A brief review of ventricular assist devices and a recommended protocol for pathology evaluations [J].
Carpenter, Brian A. ;
Gonzalez, Christian J. ;
Jessen, Staci L. ;
Moore, Erica J. ;
Thrapp, Amber N. ;
Weeks, Brad R. ;
Clubb, Fred J., Jr. .
CARDIOVASCULAR PATHOLOGY, 2013, 22 (05) :408-415
[3]  
CHANDLER AB, 1958, LAB INVEST, V7, P110
[4]   HeartWare Controller Logs A Diagnostic Tool and Clinical Management Aid for the HVAD Pump [J].
Chorpenning, Katherine ;
Brown, Michael C. ;
Voskoboynikov, Neil ;
Reyes, Carlos ;
Dierlam, Anne E. ;
Tamez, Daniel .
ASAIO JOURNAL, 2014, 60 (01) :115-118
[5]  
Dickson B.C., 2004, University of Toronto Medical Journal, V81, P166, DOI DOI 10.5015/utmj.v81i3.647
[6]   Bleeding and Thrombosis in Patients With Continuous-Flow Ventricular Assist Devices [J].
Eckman, Peter M. ;
John, Ranjit .
CIRCULATION, 2012, 125 (24) :3038-3047
[7]  
EICKER SW, 1984, J AM VET MED ASSOC, V185, P772
[8]   SPECIFIC RESISTANCE OF BLOOD AT BODY-TEMPERATURE [J].
GEDDES, LA ;
SADLER, C .
MEDICAL & BIOLOGICAL ENGINEERING, 1973, 11 (03) :336-339
[9]   Algorithm for the diagnosis and management of suspected pump thrombus [J].
Goldstein, Daniel J. ;
John, Ranjit ;
Salerno, Christopher ;
Silvestry, Scott ;
Moazami, Nader ;
Horstmanshof, Douglas ;
Adamson, Robert ;
Boyle, Andrew ;
Zucker, Mark ;
Rogers, Joseph ;
Russell, Stuart ;
Long, James ;
Pagani, Francis ;
Jorde, Ulrich .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (07) :667-670
[10]   The Role of Medical Management for Acute Intravascular Hemolysis in Patients Supported on Axial Flow LVAD [J].
Hasin, Tal ;
Deo, Salil ;
Maleszewski, Joseph J. ;
Topilsky, Yan ;
Edwards, Brooks S. ;
Pereira, Naveen L. ;
Stulak, John M. ;
Joyce, Lyle ;
Daly, Richard ;
Kushwaha, Sudhir S. ;
Park, Soon J. .
ASAIO JOURNAL, 2014, 60 (01) :9-14