Single heartbeat cardiac tagging for the evaluation of transient phenomena

被引:8
作者
Herzka, DA
Derbyshire, JA
Kellman, P
McVeigh, ER
机构
[1] NHLBI, Cardiac Energet Lab, NIH, Bethesda, MD 20892 USA
[2] Johns Hopkins Univ, Sch Med, Dept Biomed Engn, Baltimore, MD 21205 USA
关键词
myocardial tagging; myocardial function; fast cardiac imaging; parallel imaging; real time imaging; Valsalva maneuver;
D O I
10.1002/mrm.20719
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Many cardiac abnormalities are of a transient nature, creating a beat-to-beat variation in myocardial function. This work presents the cardiac imaging technique for the measurement of regional function during transient cardiac phenomena. All information necessary for the reconstruction of a cine loop is acquired within a single heartbeat, avoiding the temporal blurring introduced by segmented imaging due to the assumption of cardiac cycle periodicity. This method incorporates a gradient-optimized, high-efficiency EPI-SSFP sequence and TSENSE parallel imaging. For acquisitions with readout resolutions of 128,160, 192, and 256 points, the technique produced images with average temporal resolution of 35, 39, 43, and 52 ms and average spatial resolutions of 2.65, 2.12, 1.77, and 1.32 mm in the readout direction, respectively, and 2.88 and 2.08 mm in the phase encode direction for acceleration rates of 3 and 4, respectively. Local apparent strains in the single slice and measurements of ventricular end-systolic and end-diastolic areas were used as quantitative measures to validate the single heartbeat technique. To demonstrate the utility of the sequence, movie loops were acquired for multiple heartbeats in non- breath-held acquisitions as well as during a Valsalva maneuver. A heartbeat-interleaved acquisition allowed for the reconstruction of nonaccelerated images from R contiguous heartbeats. Images reconstructed from such data displayed tag blurring and reduced tag persistence due to motion and interheartbeat variability. Images acquired during the Valsalva maneuver demonstrated apparent beat-to-beat variability, visible both in the images and as changing strain patterns and ventricular volumes. Magn Reson Med 54:1455-1464, 2005. Published 2005 Wiley-Liss, Inc.(dagger)
引用
收藏
页码:1455 / 1464
页数:10
相关论文
共 43 条
[1]   MINIMIZATION OF DEAD-PERIODS IN MRI PULSE SEQUENCES FOR IMAGING OBLIQUE PLANES [J].
ATALAR, E ;
MCVEIGH, ER .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (06) :773-777
[2]   HEART WALL MOTION - IMPROVED METHOD OF SPATIAL MODULATION OF MAGNETIZATION FOR MR IMAGING [J].
AXEL, L ;
DOUGHERTY, L .
RADIOLOGY, 1989, 172 (02) :349-350
[3]  
BERNE RM, 1992, CARDIOVASCULAR PHYSL, P194
[4]   Multi-slice dynamic imaging: Complete functional cardiac MR examination within 15 seconds [J].
Bornstedt, A ;
Nagel, E ;
Schalla, S ;
Schnackenburg, B ;
Klein, C ;
Fleck, E .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (03) :300-305
[5]   REAL-TIME MOVIE IMAGING FROM A SINGLE CARDIAC CYCLE BY NMR [J].
CHAPMAN, B ;
TURNER, R ;
ORDIDGE, RJ ;
DOYLE, M ;
CAWLEY, M ;
COXON, R ;
GLOVER, P ;
MANSFIELD, P .
MAGNETIC RESONANCE IN MEDICINE, 1987, 5 (03) :246-254
[6]   Unsupervised reconstruction of a three-dimensional left ventricular strain from parallel tagged cardiac images [J].
Denney, TS ;
Gerber, BL ;
Yan, LT .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (04) :743-754
[7]  
DERBYSHIRE JA, 2003, P 10 ANN M ISMRM HON, P2359
[8]   THEORETICAL ASPECTS OF MOTION SENSITIVITY AND COMPENSATION IN ECHO-PLANAR IMAGING [J].
DUERK, JL ;
SIMONETTI, OP .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (06) :643-650
[9]   PHASE ERRORS IN MULTISHOT ECHO-PLANAR IMAGING [J].
FEINBERG, DA ;
OSHIO, K .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (04) :535-539
[10]   Real-time accelerated interactive MRI with adaptive TSENSE and UNFOLD [J].
Guttman, MA ;
Kellman, P ;
Dick, AJ ;
Lederman, RJ ;
McVeigh, ER .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (02) :315-321