Micro-structure diffusion scalar measures from reduced MRI acquisitions

被引:13
作者
Aja-Fernandez, Santiago [1 ,3 ]
De Luis-Garcia, Rodrigo [1 ]
Afzali, Maryam [3 ]
Molendowska, Malwina [3 ]
Pieciak, Tomasz [2 ]
Tristan-Vega, Antonio [1 ]
机构
[1] Univ Valladolid, Lab Proc Imagen LPI, Valladolid, Spain
[2] AGH Univ Sci & Technol, Krakow, Poland
[3] Univ Cardiff, Brain Res Imaging Ctr CUBRIC, Sch Psychol, Cardiff, Wales
基金
英国惠康基金; 英国工程与自然科学研究理事会;
关键词
PROPAGATOR MAP MRI; Q-SPACE; TENSOR; RESOLUTION; COMPUTATION; MATTER;
D O I
10.1371/journal.pone.0229526
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In diffusion MRI, the Ensemble Average diffusion Propagator (EAP) provides relevant micro-structural information and meaningful descriptive maps of the white matter previously obscured by traditional techniques like Diffusion Tensor Imaging (DTI). The direct estimation of the EAP, however, requires a dense sampling of the Cartesian q-space involving a huge amount of samples (diffusion gradients) for proper reconstruction. A collection of more efficient techniques have been proposed in the last decade based on parametric representations of the EAP, but they still imply acquiring a large number of diffusion gradients with different b-values (shells). Paradoxically, this has come together with an effort to find scalar measures gathering all the q-space micro-structural information probed in one single index or set of indices. Among them, the return-to-origin (RTOP), return-to-plane (RTPP), and return-to-axis (RTAP) probabilities have rapidly gained popularity. In this work, we propose the so-called "Apparent Measures Using Reduced Acquisitions" (AMURA) aimed at computing scalar indices that can mimic the sensitivity of state of the art EAP-based measures to micro-structural changes. AMURA drastically reduces both the number of samples needed and the computational complexity of the estimation of diffusion properties by assuming the diffusion anisotropy is roughly independent from the radial direction. This simplification allows us to compute closed-form expressions from single-shell information, so that AMURA remains compatible with standard acquisition protocols commonly used even in clinical practice. Additionally, the analytical form of AMURA-based measures, as opposed to the iterative, non-linear reconstruction ubiquitous to full EAP techniques, turns the newly introduced apparent RTOP, RTPP, and RTAP both robust and efficient to compute.
引用
收藏
页数:25
相关论文
共 50 条
[1]  
Aja-Fern\andez S., 2016, STAT ANAL NOISE MRI
[2]  
Aja-Fernandez S, 2018, MAGN RESON IMAG
[3]  
Alimi A, 2018, ISMRM 2018 INT SOC M, P1
[4]  
Assaf Y, 2000, MAGNET RESON MED, V44, P713, DOI 10.1002/1522-2594(200011)44:5<713::AID-MRM9>3.0.CO
[5]  
2-6
[6]   Diffusion tensor imaging in Parkinson's disease: Review and meta-analysis [J].
Atkinson-Clement, Cyril ;
Pinto, Serge ;
Eusebio, Alexandre ;
Coulon, Olivier .
NEUROIMAGE-CLINICAL, 2017, 16 :98-110
[7]   Clinical feasibility of using mean apparent propagator (MAP) MRI to characterize brain tissue microstructure [J].
Avram, Alexandru V. ;
Sarlls, Joelle E. ;
Barnett, Alan S. ;
Ozarslan, Evren ;
Thomas, Cibu ;
Irfanoglu, M. Okan ;
Hutchinson, Elizabeth ;
Pierpaoli, Carlo ;
Basser, Peter J. .
NEUROIMAGE, 2016, 127 :422-434
[8]   Impact of MR Acquisition Parameters on DTI Scalar Indexes: A Tractography Based Approach [J].
Barrio-Arranz, Gonzalo ;
de Luis-Garcia, Rodrigo ;
Tristan-Vega, Antonio ;
Martin-Fernandez, Marcos ;
Aja-Fernandez, Santiago .
PLOS ONE, 2015, 10 (10)
[9]   Relationships between diffusion tensor and q-space MRI [J].
Basser, PJ .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (02) :392-397
[10]  
Basser PJ, 1996, J MAGN RESON SER B, V111, P209, DOI 10.1016/j.jmr.2011.09.022