Visualization of Small-Diameter Vessels by Reduction of Incoherent Reverberation With Coherent Flow Power Doppler

被引:46
|
作者
Li, You Leo [1 ,2 ]
Hyun, Dongwoon [1 ,2 ]
Abou-Elkacem, Lotfi [3 ]
Willmann, Juergen Karl [3 ]
Dahl, Jeremy J. [3 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
[2] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
[3] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA 94305 USA
基金
美国国家卫生研究院;
关键词
Doppler imaging; medical ultrasound; spatial coherence; FOCAL LIVER-LESIONS; LAG SPATIAL COHERENCE; BLOOD-FLOW; ULTRASOUND; CLUTTER; PERFUSION; VELOCITY; SIMULATION; SONOGRAPHY; TIME;
D O I
10.1109/TUFFC.2016.2616112
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Power Doppler (PD) imaging is a widely used technique for flow detection. Despite the wide use of Doppler ultrasound, limitations exist in the ability of Doppler ultrasound to assess slow flow in the small-diameter vasculature, such as the maternal spiral arteries and fetal villous arteries of the placenta and focal liver lesions. The sensitivity of PD in small vessel detection is limited by the low signal produced by slow flow and the noise associated with small vessels. The noise sources include electronic noise, stationary or slowly moving tissue clutter, reverberation clutter, and off-axis scattering from tissue, among others. In order to provide more sensitive detection of slow flow in small diameter vessels, a coherent flow imaging technique, termed coherent flow PD (CFPD), is characterized and evaluated with simulation, flow phantom experiment studies, and an in vivo animal small vessel detection study. CFPD imaging was introduced as a technique to detect slow blood flow. It has been demonstrated to detect slow flow below the detection threshold of conventional PD imaging using identical pulse sequences and filter parameters. In this paper, we compare CFPD with PD in the detection of blood flow in small-diameter vessels. The results from the study suggest that CFPD is able to provide a 7.5-12.5-dB increase in the signal-to-noise ratio (SNR) over PD images for the same physiological conditions and is less susceptible to reverberation clutter and thermal noise. Due to the increase in SNR, CFPD is able to detect small vessels in high channel noise cases, for which PD was unable to generate enough contrast to observe the vessel.
引用
收藏
页码:1878 / 1889
页数:12
相关论文
共 50 条
  • [41] Pressure drop with highly subcooled flow boiling in small-diameter tubes
    Tong, W
    Bergles, AE
    Jensen, MK
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1997, 15 (03) : 202 - 212
  • [42] CONVECTIVE FLOW AND ITS EFFECT ON TEMPERATURE LOGGING IN SMALL-DIAMETER WELLS
    SAMMEL, EA
    GEOPHYSICS, 1968, 33 (06) : 1004 - &
  • [43] Mass transfer in gas-liquid flow in small-diameter tubes
    Tortopidis, P
    Bontozoglou, V
    CHEMICAL ENGINEERING SCIENCE, 1997, 52 (14) : 2231 - 2237
  • [44] The effect of surface tension on flow condensation in vertical small-diameter tube
    王补宣
    杜小泽
    ProgressinNaturalScience, 2000, (05) : 53 - 60
  • [45] ON APPLICATION OF THE CONCENTRIC ANNULAR-FLOW MODEL TO THE FLOW OF BLOOD IN SMALL-DIAMETER TUBES
    PRASASSARAKICH, P
    WALAWENDER, WP
    MICROVASCULAR RESEARCH, 1980, 20 (02) : 165 - 181
  • [46] THE USE OF HIGH-FREQUENCY ULTRASOUND FOR THE DISSECTION OF SMALL-DIAMETER BLOOD-VESSELS AND NERVES
    FISCHER, PD
    NARAYANAN, K
    LIANG, MD
    ANNALS OF PLASTIC SURGERY, 1992, 28 (04) : 326 - 330
  • [47] Stem-Cell-Based Small-Diameter Blood Vessels with 3D Printing
    Wang, Yifan
    Wang, Xinhuan
    Chen, Jun
    Wallace, Gordon
    Gu, Qi
    SMALL SCIENCE, 2024, 4 (11):
  • [48] REDUCTION OF THROMBOGENICITY IN SMALL-DIAMETER PROSTHESES SEEDED WITH AUTOLOGOUS ENDOTHELIAL-CELLS
    KOVEKER, G
    PETZKE, KH
    BORG, M
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1985, : 251 - 255
  • [49] In Situ Tissue Engineering of Functional Small-Diameter Blood Vessels by Host Circulating Cells Only
    Talacua, Hanna
    Smits, Anthal I. P. M.
    Muylaert, Dimitri E. P.
    van Rijswijk, Jan Willem
    Vink, Aryan
    Verhaar, Marianne C.
    Driessen-Mol, Anita
    van Herwerden, Lex A.
    Bouten, Carlijn V. C.
    Kluin, Jolanda
    Baaijens, Frank P. T.
    TISSUE ENGINEERING PART A, 2015, 21 (19-20) : 2583 - 2594
  • [50] Small-Diameter Vessels Reconstruction Using Cell Tissue-Engineering Graft Based on the Polycaprolactone
    Yudintceva N.M.
    Nashchekina Y.A.
    Shevtsov M.A.
    Karpovich V.B.
    Popov G.I.
    Samusenko I.A.
    Mikhailova N.A.
    Cell and Tissue Biology, 2021, 15 (6) : 577 - 585