Visualization of Small-Diameter Vessels by Reduction of Incoherent Reverberation With Coherent Flow Power Doppler

被引:46
|
作者
Li, You Leo [1 ,2 ]
Hyun, Dongwoon [1 ,2 ]
Abou-Elkacem, Lotfi [3 ]
Willmann, Juergen Karl [3 ]
Dahl, Jeremy J. [3 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
[2] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
[3] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA 94305 USA
基金
美国国家卫生研究院;
关键词
Doppler imaging; medical ultrasound; spatial coherence; FOCAL LIVER-LESIONS; LAG SPATIAL COHERENCE; BLOOD-FLOW; ULTRASOUND; CLUTTER; PERFUSION; VELOCITY; SIMULATION; SONOGRAPHY; TIME;
D O I
10.1109/TUFFC.2016.2616112
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Power Doppler (PD) imaging is a widely used technique for flow detection. Despite the wide use of Doppler ultrasound, limitations exist in the ability of Doppler ultrasound to assess slow flow in the small-diameter vasculature, such as the maternal spiral arteries and fetal villous arteries of the placenta and focal liver lesions. The sensitivity of PD in small vessel detection is limited by the low signal produced by slow flow and the noise associated with small vessels. The noise sources include electronic noise, stationary or slowly moving tissue clutter, reverberation clutter, and off-axis scattering from tissue, among others. In order to provide more sensitive detection of slow flow in small diameter vessels, a coherent flow imaging technique, termed coherent flow PD (CFPD), is characterized and evaluated with simulation, flow phantom experiment studies, and an in vivo animal small vessel detection study. CFPD imaging was introduced as a technique to detect slow blood flow. It has been demonstrated to detect slow flow below the detection threshold of conventional PD imaging using identical pulse sequences and filter parameters. In this paper, we compare CFPD with PD in the detection of blood flow in small-diameter vessels. The results from the study suggest that CFPD is able to provide a 7.5-12.5-dB increase in the signal-to-noise ratio (SNR) over PD images for the same physiological conditions and is less susceptible to reverberation clutter and thermal noise. Due to the increase in SNR, CFPD is able to detect small vessels in high channel noise cases, for which PD was unable to generate enough contrast to observe the vessel.
引用
收藏
页码:1878 / 1889
页数:12
相关论文
共 50 条
  • [1] Small-diameter Vasculature Detection with Coherent Flow Power Doppler Imaging
    Li, You Leo
    Dahl, Jeremy J.
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [2] Bioprinting of Small-Diameter Blood Vessels
    Cao, Xia
    Maharjan, Sushila
    Ashfaq, Ramla
    Shin, Jane
    Zhang, Yu Shrike
    ENGINEERING, 2021, 7 (06) : 832 - 844
  • [3] GLUE ANASTOMOSIS OF SMALL-DIAMETER VESSELS
    GIGAURI, VS
    KNYAZEV, MD
    KNYAZEVA, GD
    CINTER, EK
    KOCHARYAN, EZ
    KHIRURGIYA, 1979, (09): : 80 - 83
  • [4] CORONARY STENTING OF SMALL-DIAMETER VESSELS - IS IT SAFE
    TEIRSTEIN, PS
    SCHATZ, RA
    RUSSO, RJ
    GUARNERI, EM
    STEVENS, KM
    CIRCULATION, 1995, 92 (08) : 1333 - 1333
  • [5] Direct and Doppler angle-independent measurement of blood flow velocity in small-diameter vessels using ultrasound microbubbles
    Roy, Homagni Sikha
    Zuo, Guoqing
    Luo, Zhengchun
    Wu, Hanping
    Krupka, Tianyi M.
    Ran, Haitao
    Li, Pan
    Sun, Youping
    Wang, Zhigang
    Zheng, Yuanyi
    CLINICAL IMAGING, 2012, 36 (05) : 577 - 583
  • [6] Artificial vessels: Advances in small-diameter covered stents
    Shimamura, Kazuo
    JAPANESE JOURNAL OF ARTIFICIAL ORGANS, 2020, 49 (03):
  • [7] Small-diameter blood vessels by weaving: Prototyping and modelling
    Moghe, A. K.
    Gupta, B. S.
    JOURNAL OF THE TEXTILE INSTITUTE, 2008, 99 (05) : 467 - 477
  • [8] AN IMPROVED APPROACH TO AUTOMATED-ANALYSIS OF SMALL-DIAMETER VESSELS
    SONKA, M
    REDDY, GK
    WINNIFORD, MD
    COLLINS, SM
    CIRCULATION, 1994, 90 (04) : 487 - 487
  • [9] A BIOFUNCTIONAL VASCULAR SCAFFOLD FOR REPLACING SMALL-DIAMETER BLOOD VESSELS
    Ju, Young Min
    Kim, Ickhee
    Jackson, John
    Atala, Anthony
    Yoo, James
    Lee, Sang Jin
    JOURNAL OF UROLOGY, 2018, 199 (04): : E824 - E824
  • [10] A Biofunctional Vascular Scaffold for Replacing Small-Diameter Blood Vessels
    Ju, Y.
    Green, D.
    Kim, I.
    Atala, A.
    Yoo, J.
    Lee, S.
    TISSUE ENGINEERING PART A, 2017, 23 : S95 - S95