Angiographic core laboratory reproducibility analyses: implications for planning clinical trials using coronary angiography and left ventriculography end-points

被引:11
作者
Steigen, Terje K. [1 ,2 ]
Claudio, Cheryl [1 ]
Abbott, David [1 ]
Schulzer, Michael [3 ]
Burton, Jeff [4 ]
Tymchak, Wayne [4 ]
Buller, Christopher E. [1 ]
Mancini, G. B. John [1 ]
机构
[1] Vancouver Hosp, Div Cardiol, Cardiovasc Imaging Res Core Lab, Vancouver, BC V5Z 4E3, Canada
[2] Univ Tromso, Tromso, Norway
[3] Univ British Columbia, Vancouver Hosp, Dept Med, Vancouver, BC V5Z 1M9, Canada
[4] Univ Alberta, Div Cardiol, Edmonton, AB, Canada
关键词
angiographic core laboratory; clinical trials; reproducibility; sample size; coronary angiography; left ventriculography;
D O I
10.1007/s10554-007-9285-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives To assess reproducibility of core laboratory performance and impact on sample size calculations. Background Little information exists about overall reproducibility of core laboratories in contradistinction to performance of individual technicians. Also, qualitative parameters are being adjudicated increasingly as either primary or secondary end-points. The comparative impact of using diverse indexes on sample sizes has not been previously reported. Methods We compared initial and repeat assessments of five quantitative parameters [e.g., minimum lumen diameter (MLD), ejection fraction (EF), etc.] and six qualitative parameters [e.g., TIMI myocardial perfusion grade (TMPG) or thrombus grade (TTG), etc.], as performed by differing technicians and separated by a year or more. Sample sizes were calculated from these results. TMPG and TTG were also adjudicated by a second core laboratory. Results MLD and EF were the most reproducible, yielding the smallest sample size calculations, whereas percent diameter stenosis and centerline wall motion require substantially larger trials. Of the qualitative parameters, all except TIMI flow grade gave reproducibility characteristics yielding sample sizes of many 100's of patients. Reproducibility of TMPG and TTG was only moderately good both within and between core laboratories, underscoring an intrinsic difficulty in assessing these. Conclusions Core laboratories can be shown to provide reproducibility performance that is comparable to performance commonly ascribed to individual technicians. The differences in reproducibility yield huge differences in sample size when comparing quantitative and qualitative parameters. TMPG and TTG are intrinsically difficult to assess and conclusions based on these parameters should arise only from very large trials.
引用
收藏
页码:453 / 462
页数:10
相关论文
共 36 条
[1]  
[Anonymous], N ENGL J MED
[2]  
BAIM DS, 2000, CARDIAC CATHETERIZAT, P766
[3]  
BASHORE TM, 1990, INVASIVE CARDIOLOGY
[4]  
Beauman GJ, 1996, CATHETER CARDIO DIAG, V37, P24
[5]   ACCURACY OF INDIVIDUAL AND PANEL VISUAL INTERPRETATIONS OF CORONARY ARTERIOGRAMS - IMPLICATIONS FOR CLINICAL DECISIONS [J].
BEAUMAN, GJ ;
VOGEL, RA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (01) :108-113
[6]   COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[7]  
BOLSON EL, 1980, P IEEE COMPUT CARDIO, P245
[8]  
BROWN BG, 1993, CIRCULATION, V87, P66
[9]   A COEFFICIENT OF AGREEMENT FOR NOMINAL SCALES [J].
COHEN, J .
EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1960, 20 (01) :37-46
[10]   Frequency, correlates, and clinical implications of myocardial perfusion after primary angioplasty and stenting, with and without glycoprotein IIb/IIIa inhibition, in acute myocardial infarction [J].
Costantini, CO ;
Stone, GW ;
Mehran, R ;
Aymong, E ;
Grines, CL ;
Cox, DA ;
Stuckey, T ;
Turco, M ;
Gersh, BJ ;
Tcheng, JE ;
Garcia, E ;
Griffin, JJ ;
Guagliumi, G ;
Leon, MB ;
Lansky, AJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (02) :305-312