Comparison of sample preservation methods for clinical trace element analysis by inductively coupled plasma mass spectrometry

被引:28
作者
Bornhorst, JA
Hunt, JW
Urry, FM
McMillin, GA
机构
[1] ARUP Labs, Salt Lake City, UT 84108 USA
[2] Univ Utah, Dept Pathol, Salt Lake City, UT USA
关键词
inductively coupled plasma mass spectrometry; ICP-MS; additive; contamination; metal; preservative;
D O I
10.1309/L241WUER8831GLWB
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
The effects of chemical additives and storage temperatures on measurement of 16 trace elements in urine by inductively coupled plasma mass spectrometry (ICP-MS) were evaluated. A 24-hour urine specimen was supplemented with concentrations of the elements. Aliquots containing I of 4 chemical additives were stored at 3 different temperatures in sealed polypropylene containers. Elemental concentrations were determined by ICP-MS for the resulting samples after 1, 2, 8, and 65 days of storage. Initial element concentrations measured within 8 hours of specimen preparation were consistent with expected concentrations (except for aluminum). For most elements, preservation and storage conditions yielded consistent measured concentrations throughout the experiment. Notable exceptions were for aluminum (general rise over time) and mercury (general decrease over time). Adding boric acid and potassium pyrosulfate resulted in sample contamination; elemental contamination was concentration-dependent for both. Although little microbial contamination was observed during the experiment, refrigeration of samples is recommended to curtail bacterial growth in nonsterile specimens. In light of these results, refrigerated urine storage without the use of chemical additives is an effective preservation method for ICP-MS analysis of many trace elements.
引用
收藏
页码:578 / 583
页数:6
相关论文
共 14 条
[1]  
AITIO A, 1985, ANN CLIN LAB SCI, V15, P121
[2]  
*ARUP, 2004, ARUP US GUID
[3]  
ASH KO, 1997, HDB ANAL THERAPEUTIC, P107
[4]   Preparation of urine samples for trace metal determination: a study with aluminium analysis by inductively coupled plasma optical emission spectrometry [J].
Burden, TJ ;
Whitehead, MW ;
Thompson, RPH ;
Powell, JJ .
ANNALS OF CLINICAL BIOCHEMISTRY, 1998, 35 :245-253
[5]  
Feldmann J, 1999, CLIN CHEM, V45, P1988
[6]   Simultaneous measurement of the trace elements Al, As, B, Be, Cd, Co, Cu, Fe, Li, Mn, Mo, Ni, Rb, Se, Sr, and Zn in human serum and their reference ranges by ICP-MS [J].
Forrer, R ;
Gautschi, K ;
Lutz, H .
BIOLOGICAL TRACE ELEMENT RESEARCH, 2001, 80 (01) :77-93
[8]   Determination of urinary arsenic, mercury, and selenium in steel production workers [J].
Horng, CJ ;
Tsai, JL ;
Lin, SR .
BIOLOGICAL TRACE ELEMENT RESEARCH, 1999, 70 (01) :29-40
[9]   ANALYSIS, STORAGE STABILITY AND REFERENCE VALUES FOR URINARY CHROMIUM AND NICKEL [J].
KIILUNEN, M ;
JARVISALO, J ;
MAKITIE, O ;
AITIO, A .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1987, 59 (01) :43-50
[10]   Comparison of representative ranges based on US patient population and literature reference intervals for urinary trace elements [J].
Komaromy-Hiller, G ;
Ash, KO ;
Costa, R ;
Howerton, K .
CLINICA CHIMICA ACTA, 2000, 296 (1-2) :71-90