Rapid Detection of Myocardial Infarction With a Sensitive Troponin Test

被引:12
作者
Scharnhorst, Volkher [1 ]
Krasznai, Krisztina [2 ]
van't Veer, Marcel [2 ]
Michels, Rolf [2 ]
机构
[1] Catharina Hosp, Clin Lab, NL-5602 ZA Eindhoven, Netherlands
[2] Catharina Hosp, Dept Cardiol, NL-5602 ZA Eindhoven, Netherlands
关键词
Troponin; Acute coronary syndrome; Myocardial infarction; MEDICINE PRACTICE GUIDELINES; CARDIAC TROPONIN; CLINICAL BIOCHEMISTRY; NATIONAL ACADEMY; EARLY-DIAGNOSIS; COMMITTEE; MARKERS; ASSAY; PERFORMANCE; COLLEGE;
D O I
10.1309/AJCPA4G8AQOYEKLD
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Rapid identification and treatment of patients with a myocardial infarction (MI) is mandatory. We studied the diagnostic capacities of a sensitive troponin assay for detection of MI in emergency department patients within 2 hours after arrival. The study included 157 patients suspected of having non-ST-elevation acute coronary syndrome. Blood was drawn on arrival (T0) and 2 (T2), 6, and 12 hours later. At T2, a troponin concentration above the MI cutoff is 87% sensitive and 100% specific for MI detection (positive predictive value [PPV], 100%; negative predictive value [NPV], 96%). If a difference of more than 30% between the troponin measurements at T0 and T2 in the absence of an absolute troponin increase above the 99th percentile of a reference population is also considered indicative of MI, the sensitivity increases to 100% and specificity decreases to 87% (PPV, 70%; NPV, 100%). Sensitivity and specificity of creatine kinase-MB and myoglobin are lower than those of troponin. By using a sensitive troponin assay and simple algorithms, the diagnosis of MI can be determined within 2 hours after arrival at the emergency department. Measurement of myoglobin and creatine kinase-MB has no added value.
引用
收藏
页码:424 / 428
页数:5
相关论文
共 16 条
[11]  
*SIEM MED SOL DIAG, 2006, 200604 SIEM MED SOL
[12]   Universal definition of myocardial infarction [J].
Thygesen, Kristian ;
Alpert, Joseph S. ;
White, Harvey D. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (22) :2173-2195
[13]   Performance of the Advia Centaur second-generation troponin assay TnI-Ultra compared with the first-generation cTnI assay [J].
van de Kerkhof, Daan ;
Peters, Berry ;
Scharnhorst, Volkher .
ANNALS OF CLINICAL BIOCHEMISTRY, 2008, 45 :316-317
[14]   Clinical Performance of Two Highly Sensitive Cardiac Troponin I Assays [J].
Venge, Per ;
James, Stefan ;
Jansson, Leif ;
Lindahl, Bertil .
CLINICAL CHEMISTRY, 2009, 55 (01) :109-116
[15]   National Academy of Clinical Biochemistry Laboratory Medicine Practice Guidelines: Use of cardiac troponin and B-type natriuretic peptide or N-terminal proB-type natriuretic peptide for etiologies other than acute coronary syndromes and heart failure [J].
Wu, Alan H. B. ;
Jaffe, Allan S. ;
Apple, Fred S. ;
Jesse, Robert L. ;
Francis, Gary L. ;
Morrow, David A. ;
Newby, L. Kristin ;
Ravkilde, Jan ;
Tang, W. H. Wilson ;
Christenson, Robert H. ;
Cannon, Christopher P. ;
Storrow, Alan B. .
CLINICAL CHEMISTRY, 2007, 53 (12) :2086-2096
[16]   Short- and Long-Term Biological Variation in Cardiac Troponin I Measured with a High-Sensitivity Assay: Implications for Clinical Practice [J].
Wu, Alan H. B. ;
Lu, Quynh Anh ;
Todd, John ;
Moecks, Joachim ;
Wians, Frank .
CLINICAL CHEMISTRY, 2009, 55 (01) :52-58