Prospective study of a cementless total hip arthroplasty with a collum femoris preserving stem and a trabeculae oriented pressfit cup: minimun 6-year follow-up

被引:28
作者
Nowak, Melanie [1 ]
Nowak, Tobias E. [2 ]
Schmidt, Rainer [1 ]
Forst, Raimund [1 ]
Kress, Alexander M. [1 ]
Mueller, Lutz A. [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Orthopaed Surg, D-91054 Erlangen, Germany
[2] Johannes Gutenberg Univ Mainz, Ctr Musculoskeletal Surg, Dept Trauma Surg, D-55131 Mainz, Germany
关键词
Total hip arthroplasty; Cementless; Femoral neck preserving; Follow-up; THRUST PLATE PROSTHESIS; TAPER-DESIGN; REPLACEMENT; 10-YEAR; DISLOCATION; COMPONENT;
D O I
10.1007/s00402-010-1189-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Tissue sparing hip prostheses are becoming more and more popular especially for the treatment of younger patients. The objective of this study was to evaluate the clinical and radiological results after insertion of a tissue sparing hip prosthesis. In 47 consecutive non-selected patients (50 hips), the clinical and radiographic results of cementless total hip arthroplasty using a collum femoris preserving stem, a pressfit cup and an alumina-polyethylene pairing were prospectively evaluated. The mean age at index-surgery was 58 (36-82) years, there were 38 women and 9 men. After a mean follow-up of 6.8 years (minimum 6.1 years), two patients had died and one patient underwent revision surgery due to aseptic loosening of the stem. The overall survival rate of the acetabular component was 100% and of the femoral component 98%. The mean Harris hip score at follow-up was 94 points. The mid-term survival with this type of total hip arthroplasty is excellent and compares equal with uncemented straight stems in this age group.
引用
收藏
页码:549 / 555
页数:7
相关论文
共 30 条
  • [1] A ten- to 15-year follow-up of the Cementless Spotorno stem
    Aldinger, PR
    Breusch, SJ
    Lukoschek, M
    Mau, H
    Ewerbeck, V
    Thomsen, M
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (02): : 209 - 214
  • [2] TRANSGLUTEAL APPROACH TO THE HIP-JOINT
    BAUER, R
    KERSCHBAUMER, F
    POISEL, S
    OBERTHALER, W
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1979, 95 (1-2) : 47 - 49
  • [3] LOSS TO FOLLOW-UP - DOES IT MATTER
    BRITTON, A
    MURRAY, D
    BULSTRODE, C
    MCPHERSON, K
    DENHAM, R
    [J]. LANCET, 1995, 345 (8963) : 1511 - 1512
  • [4] ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION
    BROOKER, AF
    BOWERMAN, JW
    ROBINSON, RA
    RILEY, LH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) : 1629 - 1632
  • [5] Radiological findings and clinical results of 102 thrust-plate femoral hip prostheses - A follow-up of 2 to 8 years
    Buergi, ML
    Stoffel, KK
    Jacob, HAC
    Bereiter, HH
    [J]. JOURNAL OF ARTHROPLASTY, 2005, 20 (01) : 108 - 117
  • [6] Bone Remodeling Characteristics of a Short-Stemmed Total Hip Replacement
    Chen, Hsiang-Ho
    Morrey, Bernard F.
    An, Kai-Nan
    Luo, Zong-Ping
    [J]. JOURNAL OF ARTHROPLASTY, 2009, 24 (06) : 945 - 950
  • [7] INFLUENCE OF DESIGN PARAMETERS ON CALCAR STRESSES FOLLOWING FEMORAL-HEAD ARTHROPLASTY
    COOK, SD
    KLAWITTER, JJ
    WEINSTEIN, AM
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1980, 14 (02): : 133 - 143
  • [8] TOTAL HIP-REPLACEMENT IN CONGENITAL DISLOCATION AND DYSPLASIA OF THE HIP
    CROWE, JF
    MANI, VJ
    RANAWAT, CS
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1979, 61 (01) : 15 - 23
  • [9] DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
  • [10] Ender SA, 2006, ORTHOPADE, V35, P841, DOI 10.1007/s00132-006-0986-y