Intraocular lens power calculation for eyes with an axial length greater than 26.0 mm: Comparison of formulas and methods

被引:129
作者
Abulafia, Adi [1 ,4 ]
Barrett, Graham D. [4 ]
Rotenberg, Michael [1 ,3 ]
Kleinmann, Guy [1 ,3 ]
Levy, Adi [1 ]
Reitblat, Olga [1 ]
Koch, Douglas D. [5 ]
Wang, Li [5 ]
Assia, Ehud I. [1 ,2 ]
机构
[1] Ein Tal Eye Ctr, Tel Aviv, Israel
[2] Tel Aviv Univ, Meir Med Ctr, Ramat Aviv, Israel
[3] Kaplan Med Ctr, Rehovot, Israel
[4] Sir Charles Gairdner Hosp, Nedlands, WA 6009, Australia
[5] Baylor Coll Med, Cullen Eye Inst, Houston, TX 77030 USA
关键词
BIOMETRY;
D O I
10.1016/j.jcrs.2014.06.033
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate and compare the accuracy of formulas and methods for calculating the intraocular lens (IOL) power for eyes with an axial length (AL) greater than 26.0 mm. SETTING: Ein-Tal Eye Center, Tel-Aviv, Israel. DESIGN: Retrospective case series. METHODS: The postoperative refraction results in myopic eyes with an AL over 26.0 mm were compared with the predicted refractions calculated using standard formulas (Holladay 1, SRK/T, Hoffer Q, and Haigis) with optical IOL constants, User Group for Laser Interference Biometry constants, and an AL-adjustment method and using new-generation formulas (Barrett Universal II, Holladay 2, and Olsen). RESULTS: In 76 (71.7%) of 106 eyes, the IOL was 6.0 diopters (D) or more (Group A) and in 30 eyes (28.3%) was less than 6.0 D (Group B). In Group A, the SRK/T, Hoffer Q, Haigis, Barrett Universal II, Holladay 2, and Olsen methods met the benchmark criteria of having a prediction error of +/- 0.5 D in at least 71.0% of eyes and +/- 1.0 D in 93.0% of eyes. In Group B, only the Barrett Universal II formula and the Holladay 1 and Haigis formulas using the AL-adjusted method met those criteria. CONCLUSION: When selecting IOLs for high and extreme myopia, choosing appropriate formulas and methods can yield accurate refractive results that meet benchmark criteria.
引用
收藏
页码:548 / 556
页数:9
相关论文
共 24 条
[3]  
Barrett GD, Barrett Universal II formula
[4]  
Barrett GD A., 2010, ASCRS S CAT IOL REFR
[5]   Aiming for emmetropia after cataract surgery: Swedish National Cataract Register study [J].
Behndig, Anders ;
Montan, Per ;
Stenevi, Ulf ;
Kugelberg, Maria ;
Zetterstrom, Charlotta ;
Lundstrom, Mats .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (07) :1181-1186
[6]   Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis [J].
Haigis, W ;
Lege, B ;
Miller, N ;
Schneider, B .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (09) :765-773
[7]  
Haigis W., 2004, Intraocular Lens Power Calculations, P41
[8]  
Haigis W, 2012, ACTA CLIN CROAT, V51, P65
[9]   Intraocular lens calculation in extreme myopia [J].
Haigis, Wolfgang .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (05) :906-911
[10]  
Hill W, IOL POW CALCULATIONS