Determination of inorganic anions in the whole blood by ion chromatography

被引:9
作者
He, Xiaohui [2 ]
Mei, Yuejing [2 ]
Wang, Yuchen [1 ]
Sun, Wenjun [2 ]
Shen, Mei [1 ]
机构
[1] Southern Med Univ, Sch Publ Hlth, Hyg Detect Ctr, Guangdong Prov Key Lab Trop Dis Res, Guangzhou 510515, Guangdong, Peoples R China
[2] Southern Med Univ, Sch Basic Med, Guangzhou 510515, Guangdong, Peoples R China
关键词
Whole blood; Ion chromatography; Anions; Performance parameters; SOLID-PHASE EXTRACTION; LIQUID-CHROMATOGRAPHY; SAMPLE PREPARATION; SERUM; URINE; QUANTIFICATION; OPTIMIZATION; VALIDATION; FLUORIDE; BROMIDE;
D O I
10.1016/j.jpba.2018.09.030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fast, precise, and accurate method that can simultaneously determine 7 anions in whole blood was established by on line dialysis-double suppression ion chromatography. Performance parameters which could affect the determination of anions were optimized, including the selection of protein precipitant in samples, the amount of filtrate discarded, selection of eluent flow rate, influence of the Ag-Na column on experimental results, influence of ethylenediamines on ClO2-, and investigation of nitrogen drying. Finally, 3.6 mmol/L sodium carbonate was selected as eluent, with a flow rate of 0.8 mL/min, to separate the 7 anions. Blood and alcohol (v/v, 1:4) were used to precipitate the proteins in blood. The 7 anions reached an adequate recovery rate when the first 2 mL of filtrate from the C18 column was discarded. The recovery rate at LLOQ low, medium, and high concentrations was 80-120%. The correlation coefficients (r(2)) of the calibration curves of the targeted anions ranged from 0.9975 to 0.9998. The limit of detection (LOD) was 0.309-7.71 mu g/L. This method has simple pretreatment, high accuracy, and good reproducibility and selectivity, and is suitable for the separation and determination of anions in blood. (C) 2018 Published by Elsevier B.V.
引用
收藏
页码:58 / 63
页数:6
相关论文
共 30 条
[1]   STUDIES ON THE MECHANISM OF ACETONITRILE TOXICITY .1. WHOLE-BODY AUTORADIOGRAPHIC DISTRIBUTION AND MACROMOLECULAR INTERACTION OF 2-C-14-ACETONITRILE IN MICE [J].
AHMED, AE ;
LOH, JP ;
GHANAYEM, B ;
HUSSEIN, GI .
PHARMACOLOGY & TOXICOLOGY, 1992, 70 (05) :322-330
[2]  
[Anonymous], CURR CHROMATOGR
[3]  
[Anonymous], 2001, Guidance for industry, bioanalytical method validation
[4]   Molecular mechanisms of fluoride toxicity [J].
Barbier, Olivier ;
Arreola-Mendoza, Laura ;
Maria Del Razo, Luz .
CHEMICO-BIOLOGICAL INTERACTIONS, 2010, 188 (02) :319-333
[5]   Evaluation of select variables in the ion chromatographic determination of F-, Cl-, Br-, NO3-, SO4-2, and PO4-3 in serum samples [J].
Benzo, Z ;
Escalona, A ;
Salas, J ;
Gómez, C ;
Quintal, M ;
Marcano, E ;
Ruiz, F ;
Garaboto, A ;
Bartoli, F .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2002, 40 (02) :101-106
[6]   Iodine in autism spectrum disorders [J].
Blazewicz, Anna ;
Makarewicz, Agata ;
Korona-Glowniak, Izabela ;
Dolliver, Wojciech ;
Kocjan, Ryszard .
JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, 2016, 34 :32-37
[7]  
Blazewicz A, 2015, IODINE CHEMISTRY AND APPLICATIONS, P25
[8]   Determination of total iodine in serum and urine samples by ion chromatography with pulsed amperometric detection - Studies on analyte loss, optimization of sample preparation procedures, and validation of analytical method [J].
Blazewicz, Anna ;
Klatka, Maria ;
Dolliver, Wojciech ;
Kocjan, Ryszard .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 962 :141-146
[9]   A comparative analytical assessment of iodides in healthy and pathological human thyroids based on IC-PAD method preceded by microwave digestion [J].
Blazewicz, Anna ;
Orlicz-Szczesna, Grazyna ;
Szczesny, Piotr ;
Prystupa, Andrzej ;
Grzywa-Celinska, Anna ;
Trojnar, Marcin .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (9-10) :573-578
[10]   Sulfate in fetal development [J].
Dawson, Paul A. .
SEMINARS IN CELL & DEVELOPMENTAL BIOLOGY, 2011, 22 (06) :653-659