Pneumatic Dissection and Storage of Donor Endothelial Tissue for Descemet's Membrane Endothelial Keratoplasty A Novel Technique

被引:70
作者
Busin, Massimo [1 ,2 ,3 ]
Scorcia, Vincenzo [1 ,2 ]
Patel, Amit K. [1 ,3 ]
Salvalaio, Gianni [3 ]
Ponzin, Diego [3 ]
机构
[1] Villa Serena Hosp, Dept Ophthalmol, I-47100 Forli, Italy
[2] Magna Graecia Univ Catanzaro, Dept Ophthalmol, Catanzaro, Italy
[3] Fdn Banca Occhi Veneto, Venice, Italy
关键词
CORNEAL ENDOTHELIUM; TRANSPLANTATION;
D O I
10.1016/j.ophtha.2009.12.040
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the feasibility of pneumatic dissection of donor endothelium and the effect of 7 days of storage in tissue culture medium on the endothelial cell count. Design: Experimental study. Participants: We used 20 human donor corneoscleral tissues deemed unsuitable for transplantation. Intervention: Donor corneas were mounted on an artificial anterior chamber and the anterior stroma removed with a 300-micron microkeratome head. Air was injected into the residual donor tissue with a 30-G needle from the endothelial side to detach Descemet's membrane. The "bubble" was expanded as far as possible into the periphery. A silicone weight was attached to the scleral ring and the prepared tissue was stored in tissue culture medium for 7 days. Main Outcome Measures: Complete detachment of Descemet's membrane, size of detachment, pre- and post-storage endothelial cell counts. Results: Complete detachment of Descemet's membrane was achieved in 19 of 20 (95%) cases. In 12 (60%) cases, this was achieved with a single injection; 7 (35%) cases required repeat injections. In 1 case, Descemet's membrane could not be detached despite repeat air injections. The average size of detachment was 8.11 +/- 2.0 mm. Endothelial cell loss after 7 days of tissue culture medium storage was 4.44 +/- 4.3%. Conclusions: Descemet's membrane and endothelium can be separated from the overlying stroma with a simple technique using air dissection. An adequate size of graft tissue is obtained without the need to manually handle the tissue. The technique allows storage of the tissue in tissue culture medium with low endothelial cell loss. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references. Ophthalmology 2010; 117: 1517-1520 (C) 2010 by the American Academy of Ophthalmology.
引用
收藏
页码:1517 / 1520
页数:4
相关论文
共 11 条
[1]   Big-bubble technique to bare Descemet's membrane in anterior lamellar keratoplasty [J].
Anwar, M ;
Teichmann, KD .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (03) :398-403
[2]   Comment on donor tissue preparation for Descemet membrane endothelial keratoplasty [J].
Athanasiadis, Ioannis ;
DeWit, Deric ;
Sharma, Anant ;
Sambare, Chitra ;
Al Barwani, Baddar M. H. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (03) :407-408
[3]   Causes of primary donor failure in Descemet membrane endothelial keratoplasty [J].
Ham, Lisanne ;
Van Der Wees, Jacqueline ;
Melles, Gerrit R. J. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 145 (04) :639-644
[4]   Visual Rehabilitation Rate After Isolated Descemet Membrane Transplantation Descemet Membrane Endothelial Keratoplasty [J].
Ham, Lisanne ;
Balachandran, Chandra ;
Verschoor, Christianne A. ;
van der Wees, Jacqueline ;
Melles, Gerrit R. J. .
ARCHIVES OF OPHTHALMOLOGY, 2009, 127 (03) :252-255
[5]   A technique to harvest Descemet's membrane with viable endothelial cells for selective transplantation [J].
Ignacio, TS ;
Nguyen, TTB ;
Sarayba, MA ;
Sweet, PM ;
Piovanetti, O ;
Chuck, RS ;
Behrens, A .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (02) :325-330
[6]   Donor tissue preparation for Descemet membrane endothelial keratoplasty [J].
Lie, Jessica T. ;
Birbal, Renuka ;
Ham, Lisanne ;
van der Wees, Jacqueline ;
Melles, Gerrit R. J. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (09) :1578-1583
[7]   A technique to exercise the descemet membrane from a recipient cornea (descemetorhexis) [J].
Melles, GRJ ;
Wijdh, RHJ ;
Nieuwendaal, CP .
CORNEA, 2004, 23 (03) :286-288
[8]   Transplantation of Descemet's membrane carrying viable endothelium through a small scleral incision [J].
Melles, GRJ ;
Lander, F ;
Rietveld, FJR .
CORNEA, 2002, 21 (04) :415-418
[9]  
Pels L, 1993, CORNEAL SURG THEORY, V2nd, P622
[10]   Assessment of the human corneal endothelium: in vivo Topcon SP2000P specular microscope versus ex vivo sambacornea eye bank analyser [J].
Thuret, G. ;
Deb-Joardar, N. ;
Manissolle, C. ;
Zhao, Min ;
Peoch, M. ;
Gain, P. ;
Gavet, Y. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (02) :265-266