Prognostic role of restenosis in 10 004 patients undergoing routine control angiography after coronary stenting

被引:120
作者
Cassese, Salvatore [1 ,2 ]
Byrne, Robert A. [1 ,2 ]
Schulz, Stephanie [1 ,2 ]
Hoppman, Petra [2 ,3 ]
Kreutzer, Johanna [1 ,2 ]
Feuchtenberger, Antonia [1 ,2 ]
Ibrahim, Tareq [2 ,3 ]
Ott, Ilka [1 ,2 ]
Fusaro, Massimiliano [1 ,2 ]
Schunkert, Heribert [1 ,2 ]
Laugwitz, Karl-Ludwig [2 ,3 ]
Kastrati, Adnan [1 ,2 ]
机构
[1] Tech Univ Munich, Deutsch Herzzentrum, D-80290 Munich, Germany
[2] DZHK German Ctr Cardiovasc Res, Partner Site Munich Heart Alliance, Munich, Germany
[3] Tech Univ Munich, Klinikum Rechts Isar, Med Klin 1, D-80290 Munich, Germany
关键词
Angiography; Coronary artery disease; Restenosis; Mortality; DRUG-ELUTING STENTS; ACUTE MYOCARDIAL-INFARCTION; BARE-METAL STENTS; FOLLOW-UP; END-POINTS; IMPACT; OUTCOMES; REVASCULARIZATION; INTERVENTION; CRITERIA;
D O I
10.1093/eurheartj/ehu383
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Routine control angiography is a valuable tool with high-sensitivity in detecting restenosis after coronary stenting. However, the prognostic role of restenosis is still controversial. We investigated the impact of restenosis on 4-year mortality in patients undergoing routine control angiography after coronary stenting. All the patients undergoing successful implantation of coronary stents for de novo lesions from 1998 to 2009 and routine control angiography after 6-8 months at two centres in Munich, Germany were studied. Restenosis was defined as diameter stenosis a parts per thousand yen50% in the in-segment area at follow-up angiography. The primary outcome was 4-year mortality. The study included 10 004 patients with 15 004 treated lesions. Restenosis was detected in 2643 (26.4%) patients. Overall, there were 702 deaths during the follow-up. Of these, 218 deaths occurred among patients with restenosis and 484 deaths occurred among patients without restenosis [unadjusted hazard ratio: HR: 1.19; (95% confidence interval CI: 1.02-1.40); P = 0.03]. The Cox proportional hazards model adjusting for other variables identified restenosis as an independent correlate of 4-year mortality [HR: 1.23; (95% CI: 1.03-1.46); P = 0.02]. Other independent correlates of 4-year mortality were age [for each 10-year increase, HR: 2.34; (95% CI: 2.12-2.60); P < 0.001], diabetes mellitus [HR: 1.68; (95% CI: 1.41-1.99); P < 0.001], current smoking habit [HR: 1.39; (95% CI: 1.09-1.76); P = 0.01], and left ventricular ejection fraction [for each 5% decrease, HR: 1.39; (95% CI: 1.31-1.48); P < 0.001]. In this large cohort of patients, the presence of restenosis at follow-up angiography after coronary stenting was predictive of 4-year mortality. Whether routine control angiography after coronary stenting is beneficial and influences outcomes should be evaluated by properly designed randomized trials.
引用
收藏
页码:94 / 99
页数:6
相关论文
共 25 条
[1]   Current Treatment of In-Stent Restenosis [J].
Alfonso, Fernando ;
Byrne, Robert A. ;
Rivero, Fernando ;
Kastrati, Adnan .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (24) :2659-2673
[2]   Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis [J].
Bangalore, Sripal ;
Toklu, Bora ;
Amoroso, Nicholas ;
Fusaro, Mario ;
Kumar, Sunil ;
Hannan, Edward L. ;
Faxon, David P. ;
Feit, Frederick .
BMJ-BRITISH MEDICAL JOURNAL, 2013, 347
[3]   Outcomes and complications associated with off-label and untested use of drug-eluting stents [J].
Beohar, Nirat ;
Davidson, Charles J. ;
Kip, Kevin E. ;
Goodreau, Lynne ;
Aslanidou Vlachos, Helen ;
Meyers, Sheridan N. ;
Benzuly, Keith H. ;
Flaherty, James D. ;
Ricciardi, Mark J. ;
Bennett, Charles L. ;
Williams, David O. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 297 (18) :1992-2000
[4]   The relationship between late lumen loss and restenosis among various drug-eluting stents: A systematic review and meta-regression analysis of randomized clinical trials [J].
Brener, Sorin J. ;
Prasad, Ashok J. ;
Khan, Zubair ;
Sacchi, Terrence J. .
ATHEROSCLEROSIS, 2011, 214 (01) :158-162
[5]   Distribution of angiographic measures of restenosis after drug-eluting stent implantation [J].
Byrne, R. A. ;
Eberle, S. ;
Kastrati, A. ;
Dibra, A. ;
Ndrepepa, G. ;
Iijima, R. ;
Mehilli, J. ;
Schoemig, A. .
HEART, 2009, 95 (19) :1572-1578
[6]   Incidence and predictors of restenosis after coronary stenting in 10 004 patients with surveillance angiography [J].
Cassese, Salvatore ;
Byrne, Robert A. ;
Tada, Tomohisa ;
Pinieck, Susanne ;
Joner, Michael ;
Ibrahim, Tareq ;
King, Lamin A. ;
Fusaro, Massimiliano ;
Laugwitz, Karl-Ludwig ;
Kastrati, Adnan .
HEART, 2014, 100 (02) :153-159
[7]  
Dietz U, 1998, AM HEART J 1, V136, P613
[8]  
Eeckhout E, 2012, PERCUTANEOUS INTERVE, P785
[9]   PHYSIOLOGIC BASIS FOR ASSESSING CRITICAL CORONARY STENOSIS - INSTANTANEOUS FLOW RESPONSE AND REGIONAL DISTRIBUTION DURING CORONARY HYPEREMIA AS MEASURES OF CORONARY FLOW RESERVE [J].
GOULD, KL ;
LIPSCOMB, K ;
HAMILTON, GW .
AMERICAN JOURNAL OF CARDIOLOGY, 1974, 33 (01) :87-94
[10]  
Harrell Jr FE, 2012, HARRELL MISCELLANEOU