A Review of Titanium Zirconium (TiZr) Alloys for Use in Endosseous Dental Implants

被引:190
作者
Grandin, H. Michelle
Berner, Simon [1 ]
Dard, Michel [1 ,2 ]
机构
[1] Inst Straumann AG, CH-4052 Basel, Switzerland
[2] NYU, Coll Dent, New York, NY 10012 USA
关键词
TiZr; titanium zirconium alloy; endosseous dental implant; clinical; in vitro; in vivo; reduced or small diameter implant; ACID-ETCHED SURFACE; SMALL-DIAMETER; MECHANICAL-PROPERTIES; BONE APPOSITION; ZR; BIOCOMPATIBILITY; BIOMATERIALS; CORROSION; MAXILLA; ENERGY;
D O I
10.3390/ma5081348
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Dental implants made from binary titanium-zirconium (TiZr) alloys have shown promise as a high strength, yet biocompatible alternative to pure titanium, particularly for applications requiring small diameter implants. The aim of this review is to summarize existing literature reporting on the use of binary TiZr alloys for endosseous dental implant applications as tested in vitro, in animals and clinically. And furthermore to show that TiZr is "at least as good as" pure titanium in terms of biocompatibility and osseointergration. From the twelve papers that met the inclusion criteria, the current literature confirms that TiZr alloys produce small diameter implants with a strength up to 40% higher than conventional, cold-worked, grade IV titanium implants, and with a corrosion resistance and biocompatibility that is at least as good as pure titanium. The surface structure of TiZr is compatible with established surface treatments proven to aid in the osseointegration of titanium implants. Furthermore, binary TiZr alloys have been shown to achieve good osseointegration and high success rates both in animal and in clinical studies.
引用
收藏
页码:1348 / 1360
页数:13
相关论文
共 48 条
[1]   A Double-Blind Randomized Controlled Trial (RCT) of Titanium-13Zirconium versus Titanium Grade IV Small-Diameter Bone Level Implants in Edentulous Mandibles - Results from a 1-Year Observation Period [J].
Al-Nawas, Bilal ;
Bragger, Urs ;
Meijer, Henny J. A. ;
Naert, Ignace ;
Persson, Rigmor ;
Perucchi, Alessandro ;
Quirynen, Marc ;
Raghoebar, Gerry M. ;
Reichert, Torsten E. ;
Romeo, Eugenio ;
Santing, Hendrik J. ;
Schimmel, Martin ;
Storelli, Stefano ;
ten Bruggenkate, Christiaan ;
Vandekerckhove, Betty ;
Wagner, Wilfried ;
Wismeijer, Daniel ;
Mueller, Frauke .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (06) :896-904
[2]   The impact of loads on standard diameter, small diameter and mini implants: a comparative laboratory study [J].
Allum, Simon Rupert ;
Tomlinson, Rachel Anne ;
Joshi, Rajendra .
CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (06) :553-559
[3]  
[Anonymous], 2012, 58322201208 DIN ISO
[4]  
[Anonymous], 2012, 58323201208 DIN EN I
[5]  
[Anonymous], 2001, 583211200104 DIN ISO
[6]   A pilot study to evaluate the success and survival rate of titanium-zirconium implants in partially edentulous patients: results after 24 months of follow-up [J].
Barter, Stephen ;
Stone, Paul ;
Braegger, Urs .
CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (07) :873-881
[7]  
Bernhard N., 2009, FORUM IMPLANTOL, V5, P30
[8]  
Bornstein MM, 2003, INT J ORAL MAX IMPL, V18, P659
[9]   OSSEOINTEGRATION AND ITS EXPERIMENTAL BACKGROUND [J].
BRANEMARK, PI .
JOURNAL OF PROSTHETIC DENTISTRY, 1983, 50 (03) :399-410
[10]  
Buser D, 1999, J BIOMED MATER RES, V45, P75, DOI 10.1002/(SICI)1097-4636(199905)45:2<75::AID-JBM1>3.0.CO