On the treatment of ill-conditioned cases in the Monte Carlo library least-squares approach for inverse radiation analyzers

被引:14
作者
Meric, Ilker [1 ,2 ,3 ]
Johansen, Geir A. [1 ,2 ]
Holstad, Marie B. [2 ,4 ]
Mattingly, John [3 ]
Gardner, Robin P. [3 ]
机构
[1] Univ Bergen, Dept Phys & Technol, N-5007 Bergen, Norway
[2] Michelsen Ctr Ind Sci & Technol, N-5892 Bergen, Norway
[3] N Carolina State Univ, Dept Nucl Engn, CEAR, Raleigh, NC 27695 USA
[4] Christian Michelsen Res AS, CMR Instrumentat, N-5892 Bergen, Norway
关键词
prompt gamma-ray neutron activation analysis (PGNAA); Monte Carlo library least-squares (MCLLS); singular value decomposition (SVD); truncated singular value decomposition (TSVD); multiphase flow; PGNAA;
D O I
10.1088/0957-0233/23/5/055603
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Prompt gamma-ray neutron activation analysis (PGNAA) has been and still is one of the major methods of choice for the elemental analysis of various bulk samples. This is mostly due to the fact that PGNAA offers a rapid, non-destructive and on-line means of sample interrogation. The quantitative analysis of the prompt gamma-ray data could, on the other hand, be performed either through the single peak analysis or the so-called Monte Carlo library least-squares (MCLLS) approach, of which the latter has been shown to be more sensitive and more accurate than the former. The MCLLS approach is based on the assumption that the total prompt gamma-ray spectrum of any sample is a linear combination of the contributions from the individual constituents or libraries. This assumption leads to, through the minimization of the chi-square value, a set of linear equations which has to be solved to obtain the library multipliers, a process that involves the inversion of the covariance matrix. The least-squares solution may be extremely uncertain due to the ill-conditioning of the covariance matrix. The covariance matrix will become ill-conditioned whenever, in the subsequent calculations, two or more libraries are highly correlated. The ill-conditioning will also be unavoidable whenever the sample contains trace amounts of certain elements or elements with significantly low thermal neutron capture cross-sections. In this work, a new iterative approach, which can handle the ill-conditioning of the covariance matrix, is proposed and applied to a hydrocarbon multiphase flow problem in which the parameters of interest are the separate amounts of the oil, gas, water and salt phases. The results of the proposed method are also compared with the results obtained through the implementation of a well-known regularization method, the truncated singular value decomposition. Final calculations indicate that the proposed approach would be able to treat ill-conditioned cases appropriately.
引用
收藏
页数:11
相关论文
共 18 条
[1]  
[Anonymous], 2005, PARAMETER ESTIMATION, DOI DOI 10.1016/C2015-0-02458-3
[2]  
[Anonymous], SPWLA 47 ANN LOGG S
[3]   In situ determination of salinity by PGNAA [J].
Borsaru, M ;
Smith, C ;
Merritt, J ;
Aizawa, T ;
Rojc, A .
APPLIED RADIATION AND ISOTOPES, 2006, 64 (05) :630-637
[4]   ESTIMATE FOR THE CONDITION NUMBER OF A MATRIX [J].
CLINE, AK ;
MOLER, CB ;
STEWART, GW ;
WILKINSON, JH .
SIAM JOURNAL ON NUMERICAL ANALYSIS, 1979, 16 (02) :368-375
[5]  
Gardner RP, 2005, J RADIOANAL NUCL CH, V264, P221, DOI 10.1007/s10967-005-0697-6
[6]   Single peak versus library least-squares analysis methods for the PGNAA analysis of vitrified waste [J].
Gardner, RP ;
Sood, A ;
Wang, YY ;
Liu, L ;
Guo, P ;
Gehrke, RJ .
APPLIED RADIATION AND ISOTOPES, 1997, 48 (10-12) :1331-1335
[7]   Monte Carlo aided treatments of the nonlinear inverse PGNAA measurement problem for various continuous on-line applications [J].
Gardner, RP ;
Guo, P ;
Sood, A ;
Mayo, CW ;
Gehrke, RJ ;
Dobbs, CL .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1998, 233 (1-2) :105-107
[8]   The Monte Carlo code CEARCPG for coincidence prompt gamma-ray neutron activation analysis [J].
Han, Xiaogang ;
Gardner, Robin P. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 263 (01) :320-325
[9]   THE TRUNCATED SVD AS A METHOD FOR REGULARIZATION [J].
HANSEN, PC .
BIT, 1987, 27 (04) :534-553
[10]   Applications of Prompt Gamma Ray Neutron Activation Analysis: Detection of Illicit Materials [J].
Im, Hee-Jung ;
Song, Kyuseok .
APPLIED SPECTROSCOPY REVIEWS, 2009, 44 (04) :317-334