High topographical accuracy by optical shot noise reduction in digital holographic microscopy

被引:22
作者
Leon-Rodriguez, Miguel [1 ]
Rodriguez-Vera, Ramon [1 ]
Rayas, Juan A. [1 ]
Calixto, Sergio [1 ]
机构
[1] Ctr Invest Opt, Guanajuato 37150, Mexico
关键词
PARTIAL SPATIAL COHERENCE; ABERRATION COMPENSATION; SPECKLE NOISE; IMAGE; SHAPE;
D O I
10.1364/JOSAA.29.000498
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this work, we present a new method to reduce the shot noise in phase imaging of digital holograms. A spatial averaging process of phase images reconstructed at different reconstruction distances is performed, with the reconstruction distance range being specified by the numerical focus depth of the optical system. An improved phase image is attained with a 50% shot noise reduction. We use the integral of the angular spectrum as a reconstruction method to obtain a single-object complex amplitude that is needed to perform our proposal. We also show the corresponding simulations and experimental results. The topography of a homemade TiO2 stepwise of 100 nm high was measured and compared with the atomic force microscope results. (C) 2012 Optical Society of America
引用
收藏
页码:498 / 506
页数:9
相关论文
共 30 条
  • [11] Speckle noise reduction for digital holographic images using Swin Transformer
    Xie, Zhaoqian
    Chen, Li
    Chen, Honghui
    Wen, Kunhua
    Guo, Junwei
    OPTICS AND LASERS IN ENGINEERING, 2025, 184
  • [12] Single-shot 3D topography of reflective samples with digital holographic microscopy
    Castaneda, Raul
    Garcia-Sucerquia, Jorge
    APPLIED OPTICS, 2018, 57 (01) : A12 - A18
  • [13] Achievement on Unwrapping High Cycle Density of Noisy Phase Maps for Digital Holographic Microscopy
    Wang, Mingqing
    Li, Fang
    Zheng, Ming
    Lu, Wei
    Zhao, Sufen
    Yu, Qingnan
    Jia, Yan
    Wu, Jian
    ANNALEN DER PHYSIK, 2018, 530 (05)
  • [14] Accurate single-shot quantitative phase imaging of biological specimens with telecentric digital holographic microscopy
    Doblas, Ana
    Sanchez-Ortiga, Emilio
    Martinez-Corral, Manuel
    Saavedra, Genaro
    Garcia-Sucerquia, Jorge
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (04)
  • [15] Phase measurement accuracy in digital holographic microscopy using a wavelength-stabilized laser diode
    Lee, Yueh-Long
    Lin, Yu-Chih
    Tu, Han-Yen
    Cheng, Chau-Jern
    JOURNAL OF OPTICS, 2013, 15 (02)
  • [16] Alignment-tolerant single-shot digital holographic microscopy based on computer-controlled telecentricity
    Park, Seong-Jin
    Kim, Byung-Mok
    Kim, Eun-Soo
    APPLIED OPTICS, 2019, 58 (12) : 3260 - 3271
  • [17] Single-shot digital holographic microscopy with a modified lateral-shearing interferometer based on computational telecentricity
    Kim, Byung-Mok
    Park, Seong-Jin
    Kim, Eun-Soo
    OPTICS EXPRESS, 2017, 25 (06): : 6151 - 6168
  • [18] Common-path, single-shot phase-shifting digital holographic microscopy using a Ronchi ruling
    Yaghoubi, S. Hossein S.
    Ebrahimi, Samira
    Dashtdar, Masoomeh
    Doblas, Ana
    Javidi, Bahram
    APPLIED PHYSICS LETTERS, 2019, 114 (18)
  • [19] Quantitative measurement for the structure of defects on optical surface with lensless Fourier transform digital holographic microscopy
    Jiang, Hongzhen
    Liu, Yong
    Liu, Xu
    Li, Dong
    Zheng, Fanglan
    Yu, Deqiang
    Yang, Yi
    Zhang, Lin
    Ren, Huan
    Yang, Xiaoyu
    Chen, Bo
    OPTIK, 2016, 127 (15): : 5865 - 5869
  • [20] Single-path single-shot phase-shifting digital holographic microscopy without a laser light source
    Tahara, Tatsuki
    Kozawa, Yuichi
    Oi, Ryutaro
    OPTICS EXPRESS, 2022, 30 (02): : 1182 - 1194