2001 ARRS Executive Council Award II - Fast three-point Dixon MR imaging using low-resolution images for phase correction: A comparison with chemical shift selective fat suppression of pediatric musculoskeletal imaging

被引:34
作者
Rybicki, FJ
Chung, T
Reid, J
Jaramillo, D
Mulkern, RV
Ma, JF
机构
[1] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Boston, MA 02115 USA
[3] Texas Childrens Hosp, Edward B Singleton Dept Diagnost Imaging, Houston, TX 77030 USA
[4] Baylor Coll Med, Houston, TX 77030 USA
[5] Cleveland Clin Fdn, Childrens Hosp, Dept Radiol, Cleveland, OH 44195 USA
[6] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[7] Univ Texas, MD Anderson Canc Ctr, Dept Radiol, Houston, TX 77030 USA
[8] Childrens Hosp, Dept Radiol, Boston, MA 02115 USA
关键词
D O I
10.2214/ajr.177.5.1771019
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study is to describe and to implement a new fast three-point Dixon MR imaging sequence with online image reconstruction, and to compare this sequence with conventional chemical shift selective (CHESS) suppression of fat in pediatric musculoskeletal imaging SUBJECTS AND METHODS. A three-point Dixon technique using a fast spin-echo sequence with a new phase-correction algorithm providing online image reconstruction was implemented on a 1.5-T scanner. Twelve pediatric patients and young adults were imaged with both the new three-point Dixon and conventional CHESS sequences. Three radiologists unaware of imaging parameters and clinical information independently scored the homogeneity of fat suppression and conspicuity of abnormality using a four-point system. An additional comparison between the two techniques was made using a phantom. RESULTS. The three-point Dixon method showed superior fat suppression and lesion conspicuity (p < 0.001), particularly in the hands and feet, where CHESS is prone to inconsistent fat suppression. The phantom study showed no significant difference in the ratio of suppressed fat signal to background noise and more homogeneous fat suppression using the three-point Dixon method. CONCLUSION. Compared with CHESS, the new fast three-point Dixon sequence with online image reconstruction provides superior fat suppression and lesion conspicuity and can be routinely used in pediatric musculoskeletal imaging.
引用
收藏
页码:1019 / 1023
页数:5
相关论文
共 18 条
[1]  
Barnewolt C E, 1998, Magn Reson Imaging Clin N Am, V6, P441
[2]   Fat suppression using direct phase encoding: Musculoskeletal applications using MR imaging [J].
Carson, BW ;
Xiang, QS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (01) :230-233
[3]   Breast cancer: Gadolinium-enhanced MR imaging with a 0.5-T open imager and three-point Dixon technique [J].
Daniel, BL ;
Butts, K ;
Glover, GH ;
Cooper, C ;
Herfkens, RJ .
RADIOLOGY, 1998, 207 (01) :183-190
[4]   SIMPLE PROTON SPECTROSCOPIC IMAGING [J].
DIXON, WT .
RADIOLOGY, 1984, 153 (01) :189-194
[5]   THE INTRINSIC SIGNAL-TO-NOISE RATIO IN NMR IMAGING [J].
EDELSTEIN, WA ;
GLOVER, GH ;
HARDY, CJ ;
REDINGTON, RW .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (04) :604-618
[6]   MULTIPOINT DIXON TECHNIQUE FOR WATER AND FAT PROTON AND SUSCEPTIBILITY IMAGING [J].
GLOVER, GH .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (05) :521-530
[7]   3-POINT DIXON TECHNIQUE FOR TRUE WATER FAT DECOMPOSITION WITH BO INHOMOGENEITY CORRECTION [J].
GLOVER, GH ;
SCHNEIDER, E .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :371-383
[8]   SEPARATION OF FAT AND WATER IN FAST SPIN-ECHO MR-IMAGING WITH THE 3-POINT DIXON TECHNIQUE [J].
HARDY, PA ;
HINKS, RS ;
TKACH, JA .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (02) :181-185
[9]   Optimization of chemical shift selective suppression of fat [J].
Kuroda, K ;
Oshio, K ;
Mulkern, RV ;
Jolesz, FA .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (04) :505-510
[10]  
MA J, 1998, P 6 ANN SCI M INT SO, P622