Recent Advances in Electrochemical Aptasensors for Detection of Biomarkers

被引:27
作者
Majdinasab, Marjan [1 ]
Marty, Jean Louis [2 ]
机构
[1] Shiraz Univ, Sch Agr, Dept Food Sci & Technol, Shiraz 7144165186, Iran
[2] Univ Perpignan Via Domitia, 52 Ave Paul Alduy, F-66860 Perpignan 9, France
关键词
aptamer; biosensor; aptasensor; electrochemical; biomarker; LABEL-FREE APTASENSOR; SENSITIVE DETECTION; SANDWICH-TYPE; MALARIA APTASENSOR; TROPONIN-I; CANCER; NANOPARTICLES; IMMUNOSENSOR; NANOFIBERS; ELECTRODE;
D O I
10.3390/ph15080995
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
The early diagnosis of diseases is of great importance for the effective treatment of patients. Biomarkers are one of the most promising medical approaches in the diagnosis of diseases and their progress and facilitate reaching this goal. Among the many methods developed in the detection of biomarkers, aptamer-based biosensors (aptasensors) have shown great promise. Aptamers are promising diagnostic molecules with high sensitivity and selectivity, low-cost synthesis, easy modification, low toxicity, and high stability. Electrochemical aptasensors with high sensitivity and accuracy have attracted considerable attention in the field of biomarker detection. In this review, we will summarize recent advances in biomarker detection using electrochemical aptasensors. The principles of detection, sensitivity, selectivity, and other important factors in aptasensor performance are investigated. Finally, advantages and challenges of the developed aptasensors are discussed.
引用
收藏
页数:31
相关论文
共 110 条
[1]   Label-free aptasensor for the detection of cardiac biomarker myoglobin based on gold nanoparticles decorated boron nitride nanosheets [J].
Adeel, Muhammad ;
Rahman, Md. Mahbubur ;
Lee, Jae-Joon .
BIOSENSORS & BIOELECTRONICS, 2019, 126 :143-150
[2]   Laboratory biomarkers of Multiple Sclerosis (MS) [J].
Arneth, Borros ;
Kraus, Joerg .
CLINICAL BIOCHEMISTRY, 2022, 99 :1-8
[3]   Lung Cancer and Its Early Detection Using Biomarker-Based Biosensors [J].
Arya, Sunil K. ;
Bhansali, Shekhar .
CHEMICAL REVIEWS, 2011, 111 (11) :6783-6809
[4]   In situ monitoring of gating approach on mesoporous silica nanoparticles thin-film generated by the EASA method for electrochemical detection of insulin [J].
Asadpour, Farzaneh ;
Mazloum-Ardakani, Mohammad ;
Hoseynidokht, Farzaneh ;
Moshtaghioun, Seyed Mohammad .
BIOSENSORS & BIOELECTRONICS, 2021, 180
[5]   Nanomaterial-based aptasensors as an efficient substitute for cardiovascular disease diagnosis: Future of smart biosensors [J].
Azzouz, Abdelmonaim ;
Hejji, Lamia ;
Sonne, Christian ;
Kim, Ki-Hyun ;
Kumar, Vanish .
BIOSENSORS & BIOELECTRONICS, 2021, 193
[6]  
Battersby BJ, 2012, WOODH PUBL SER BIOM, V45, P191
[7]  
Bhansali S., 2015, U.S. Patent, Patent No. [Application 20150247816, 20150247816]
[8]   An electrochemical aptasensor for analysis of MUC1 using gold platinum bimetallic nanoparticles deposited carboxylated graphene oxide [J].
Bharti, Anu ;
Rana, Shilpa ;
Dahiya, Divya ;
Agnihotri, Navneet ;
Prabhakar, Nirmal .
ANALYTICA CHIMICA ACTA, 2020, 1097 :186-195
[9]   Glycated Albumin Measurement Using an Electrochemical Aptasensor for Screening and Monitoring of Diabetes Mellitus [J].
Bunyarataphan, Sasinee ;
Dharakul, Tararaj ;
Fucharoen, Suthat ;
Paiboonsukwong, Kittiphong ;
Japrung, Deanpen .
ELECTROANALYSIS, 2019, 31 (11) :2254-2261
[10]   A multiple aptasensor for ultrasensitive detection of miRNAs by using covalent-organic framework nanowire as platform and shell-encoded gold nanoparticles as signal labels [J].
Cao, Zhengming ;
Duan, Fenghe ;
Huang, Xiaoyu ;
Liu, Yang ;
Zhou, Nan ;
Xia, Lei ;
Zhang, Zhihong ;
Du, Miao .
ANALYTICA CHIMICA ACTA, 2019, 1082 :176-185