Assessment of radiochromic gel dosimeter based on Turnbull Blue dye for relative output factor measurements of the Leksell Gamma Knife® Perfexion™

被引:3
作者
Kozubikova, P. [1 ,3 ,4 ]
Solc, J. [2 ]
Novotny, J., Jr. [1 ,3 ,4 ]
Pilarova, K. [1 ]
Pipek, J. [1 ]
Koncekova, J. [1 ,3 ]
机构
[1] Czech Tech Univ, Fac Nucl Sci & Phys Engn, Dept Dosimetry & Applicat Ionising Radiat, Prague, Czech Republic
[2] Czech Metrol Inst, Inspectorate Ionizing Radiat, Prague, Czech Republic
[3] Na Homolce Hosp, Prague, Czech Republic
[4] Univ Hosp Motol, Dept Radiat Oncol, Prague, Czech Republic
来源
8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE) | 2015年 / 573卷
关键词
D O I
10.1088/1742-6596/573/1/012049
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of the study was to perform assessment of radiochromic gel dosimeter based on Turnbull blue dye formed by irradiation (TB gel dosimeter) for measurement of ROFs for 4 mm and 8 mm collimators for the Leksell Gamma Knife PerfexionTM. All measurements have been carried out using home-made spherical Perspex glass phantom of diameter 160 mm TB gel dosimeters were scanned using homemade optical CT scanner. The results are compared with vendor recommended Monte Carlo calculated ROFs values of 0.814 and 0.900 for 4 mm and 8 mm collimators, respectively. The comparisons between the gel measurements and the treatment planning system (TPS) calculation are presented in the form of 2D isodoses for the central slices and 1D profile. Measured ROF 0.746 and 0.874 for 4 mm and 8 mm collimators respectively are in a reasonable agreement with vendor recommended values and measured relative dose distribution in a central slice and measured profiles of all shots show excellent correspondence with TPS.
引用
收藏
页数:4
相关论文
共 5 条
  • [1] Gamma Knife output factor measurements using VIP polymer gel dosimetry
    Moutsatsos, A.
    Petrokokkinos, L.
    Karaiskos, P.
    Papagiannis, P.
    Georgiou, E.
    Dardoufas, K.
    Sandilos, P.
    Torrens, M.
    Pantelis, E.
    Kantemiris, I.
    Sakelliou, L.
    Seimenis, I.
    [J]. MEDICAL PHYSICS, 2009, 36 (09) : 4277 - 4287
  • [2] Semnicka J, 2013, THESIS CZECH TECHNIC
  • [3] Solc Jaroslav, 2010, Journal of Physics: Conference Series, V250, DOI 10.1088/1742-6596/250/1/012013
  • [4] SOLC J, 2007, IEEE MED IM C 2007, P468
  • [5] New radiochromic gel for 3D dosimetry based on Turnbull blue: basic properties
    Solc, Jaroslav
    Spevacek, Vaclav
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (17) : 5095 - 5107