Fast reconstruction of digital tomosynthesis using on-board images

被引:15
作者
Yan, Hui [1 ]
Godfrey, Devon J. [1 ]
Yin, Fang-Fang [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27710 USA
基金
美国国家卫生研究院;
关键词
digital tomosynthesis (DTS); cone-beam computed tomography (CBCT); image guided radiation therapy; digitally reconstructed radiograph (DRR);
D O I
10.1118/1.2896077
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Digital tomosynthesis (DTS) is a method to reconstruct pseudo three-dimensional (3D) volume images from two-dimensional x-ray projections acquired over limited scan angles. Compared with cone-beam computed tomography, which is frequently used for 3D image guided radiation therapy, DTS requires less imaging time and dose. Successful implementation of DTS for fast target localization requires the reconstruction process to be accomplished within tight clinical time constraints (usually within 2 min). To achieve this goal, substantial improvement of reconstruction efficiency is necessary. In this study, a reconstruction process based upon the algorithm proposed by Feldkamp, Davis, and Kress was implemented on graphics hardware for the purpose of acceleration. The performance of the novel reconstruction implementation was tested for phantom and real patient cases. The efficiency of DTS reconstruction was improved by a factor of 13 on average, without compromising image quality. With acceleration of the reconstruction algorithm, the whole DTS generation process including data preprocessing, reconstruction, and DICOM conversion is accomplished within 1.5 min, which ultimately meets clinical requirement for on-line target localization. (c) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:2162 / 2169
页数:8
相关论文
共 25 条
[1]  
Avinash K. C., 2001, PRINCIPLES COMPUTERI
[2]  
COLSHER JG, 2006, COMPUT GRAPH IMAGE P, V6, P513
[3]  
Dobbins III James T., 1990, US Patent, Patent No. [4903204, US4903204 A]
[4]   Digital x-ray tomosynthesis: current state of the art and clinical potential [J].
Dobbins, JT ;
Godfrey, DJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (19) :R65-R106
[5]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[6]  
Foley J. D., 1990, Computer Graphics, Principles and Practice, V2nd
[7]   Evaluation of three types of reference image data for external beam radiotherapy target localization using digital tomosynthesis (DTS) [J].
Godfrey, Devon J. ;
Ren, Lei ;
Yan, Hui ;
Wu, Q. ;
Yoo, Sua ;
Oldham, M. ;
Yin, Fang Fang .
MEDICAL PHYSICS, 2007, 34 (08) :3374-3384
[8]   Digital tomosynthesis with an on-board kilovoltage imaging device [J].
Godfrey, DJ ;
Yin, FF ;
Oldham, M ;
Yoo, S ;
Willett, C .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (01) :8-15
[9]   Practical strategies for the clinical implementation of matrix inversion tomosynthesis (MITS) [J].
Godfrey, DJ ;
Rader, A ;
Dobbins, JT .
MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 :379-390
[10]   Optimization of matrix inverse tomosynthesis [J].
Godfrey, DJ ;
Warp, RJ ;
Dobbins, JT .
MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 :696-704