Comparison of the Classification Results Accuracy for CT Soft Tissue and Bone Reconstructions in Detecting the Porosity of a Spongy Tissue

被引:3
作者
Dzierzak, Roza [1 ]
Omiotek, Zbigniew [1 ]
Tkacz, Ewaryst [2 ]
Uhlig, Sebastian [3 ]
机构
[1] Lublin Univ Technol, Dept Elect & Informat Technol, Ul Nadbystrzycka 38 A, PL-20618 Lublin, Poland
[2] Silesian Tech Univ, Dept Biosensors & Proc Biomed Signals, Ul Roosevelta 40, PL-44800 Zabrze, Poland
[3] Med Univ Lublin, Dept Med Radiol, Ul Jaczewskiego 8, PL-20090 Lublin, Poland
关键词
osteoporosis; soft tissue reconstruction; bone reconstruction; texture analysis; classification; TEXTURE ANALYSIS; DOSE REDUCTION; OSTEOPOROSIS; DIAGNOSIS; MICROARCHITECTURE; IMAGES;
D O I
10.3390/jcm11154526
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of the study was to compare the accuracy of the classification pertaining to the results of two types of soft tissue and bone reconstructions of the spinal CT in detecting the porosity of L1 vertebral body spongy tissue. The dataset for each type of reconstruction (high-resolution bone reconstruction and soft tissue reconstruction) included 400 sponge tissue images from 50 healthy patients and 50 patients with osteoporosis. Texture feature descriptors were calculated based on the statistical analysis of the grey image histogram, autoregression model, and wavelet transform. The data dimensional reduction was applied by feature selection using nine methods representing various approaches (filter, wrapper, and embedded methods). Eleven methods were used to build the classifier models. In the learning process, hyperparametric optimization based on the grid search method was applied. On this basis, the most effective model and the optimal subset of features for each selection method used were determined. In the case of bone reconstruction images, four models achieved a maximum accuracy of 92%, one of which had the highest sensitivity of 95%, with a specificity of 89%. For soft tissue reconstruction images, five models achieved the highest testing accuracy of 95%, whereas the other quality indices (TPR and TNR) were also equal to 95%. The research showed that the images derived from soft tissue reconstruction allow for obtaining more accurate values of texture parameters, which increases the accuracy of the classification and offers better possibilities for diagnosing osteoporosis.
引用
收藏
页数:14
相关论文
共 56 条
  • [21] Oriented fractal analysis for improved bone microarchitecture characterization
    Harrar, Khaled
    Jennane, Rachid
    Zaouchi, Karitna
    Janvier, Thomas
    Toumi, Hechmi
    Lespessailles, Eric
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2018, 39 : 474 - 485
  • [22] Hassani A.S.E.B.E., 2012, P 2012 9 IEEE INT S, DOI [10.1109/ISBI.2012.6235853, DOI 10.1109/ISBI.2012.6235853]
  • [23] One dimensional local binary pattern for bone texture characterization
    Houam, Lotfi
    Hafiane, Adel
    Boukrouche, Abdelhani
    Lespessailles, Eric
    Jennane, Rachid
    [J]. PATTERN ANALYSIS AND APPLICATIONS, 2014, 17 (01) : 179 - 193
  • [24] TEXTURED IMAGE SEGMENTATION BY CONTEXT ENHANCED CLUSTERING
    HU, Y
    DENNIS, TJ
    [J]. IEE PROCEEDINGS-VISION IMAGE AND SIGNAL PROCESSING, 1994, 141 (06): : 413 - 421
  • [25] Reconstruction filters and contrast detail curves in CT - art. no. 691710
    Huda, W.
    Ogden, K. M.
    Samei, E.
    Scalzetti, E. M.
    Lavallee, R. L.
    Roskopf, M. L.
    Groat, G. E.
    [J]. MEDICAL IMAGING 2008: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2008, 6917 : 91710 - 91710
  • [26] Diagnosis of osteoporosis and assessment of fracture risk
    Kanis, JA
    [J]. LANCET, 2002, 359 (9321) : 1929 - 1936
  • [27] Klibanski A, 2001, JAMA-J AM MED ASSOC, V285, P785
  • [28] A Preliminary Study on Discrimination of Osteoporotic Fractured Group from Nonfractured Group using Support Vector Machine
    Lee, Sooyeul
    Lee, Jeong Won
    Jeong, Ji-Wook
    Yoo, Done-Sik
    Kim, Seunghwan
    [J]. 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vols 1-8, 2008, : 474 - 477
  • [29] TISSUE CHARACTERIZATION BY MAGNETIC-RESONANCE SPECTROSCOPY AND IMAGING - RESULTS OF A CONCERTED RESEARCH-PROJECT OF THE EUROPEAN-ECONOMIC-COMMUNITY .8. MR IMAGE TEXTURE ANALYSIS - AN APPROACH TO TISSUE CHARACTERIZATION
    LERSKI, RA
    STRAUGHAN, K
    SCHAD, LR
    BOYCE, D
    BLUML, S
    ZUNA, I
    [J]. MAGNETIC RESONANCE IMAGING, 1993, 11 (06) : 873 - 887
  • [30] Clinical interest of bone texture analysis in osteoporosis: a case control multicenter study
    Lespessailles, E.
    Gadois, C.
    Kousignian, I.
    Neveu, J. P.
    Fardellone, P.
    Kolta, S.
    Roux, C.
    Do-Huu, J. P.
    Benhamou, C. L.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2008, 19 (07) : 1019 - 1028