Feasibility of low-cost particle sensor types in long-term indoor air pollution health studies after repeated calibration, 2019-2021

被引:8
作者
Anastasiou, Elle [1 ]
Vilcassim, M. J. Ruzmyn [3 ]
Adragna, John [2 ]
Gill, Emily [1 ]
Tovar, Albert [1 ]
Thorpe, Lorna E. [1 ]
Gordon, Terry [2 ]
机构
[1] NYU, Dept Populat Hlth, Grossman Sch Med, 180 Madison Ave, New York, NY 10016 USA
[2] NYU, Dept Environm Sci, Grossman Sch Med, 341 East 25th St, New York, NY 10010 USA
[3] Univ Alabama Birmingham, Dept Environm Hlth Sci, Sch Publ Hlth, Birmingham, AL 20593 USA
基金
美国国家卫生研究院;
关键词
PARTICULATE MATTER;
D O I
10.1038/s41598-022-18200-0
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Previous studies have explored using calibrated low-cost particulate matter (PM) sensors, but important research gaps remain regarding long-term performance and reliability. Evaluate longitudinal performance of low-cost particle sensors by measuring sensor performance changes over 2 years of use. 51 low-cost particle sensors (Airbeam 1 N = 29; Airbeam 2 N = 22) were calibrated four times over a 2-year timeframe between 2019 and 2021. Cigarette smoke-specific calibration curves for Airbeam 1 and 2 PM sensors were created by directly comparing simultaneous 1-min readings of a Thermo Scientific Personal DataRAM PDR-1500 unit with a 2.5 mu m inlet. Inter-sensor variability in calibration coefficient was high, particularly in Airbeam 1 sensors at study initiation. Calibration coefficients for both sensor types trended downwards over time to < 1 at final calibration timepoint [Airbeam 1 Mean (SD) = 0.87 (0.20); Airbeam 2 Mean (SD) = 0.96 (0.27)]. We lost more Airbeam 1 sensors (N = 27 out of 56, failure rate 48.2%) than Airbeam 2 (N = 2 out of 24, failure rate 8.3%) due to electronics, battery, or data output issues. Evidence suggests degradation over time might depend more on particle sensor type, rather than individual usage. Repeated calibrations of low-cost particle sensors may increase confidence in reported PM levels in longitudinal indoor air pollution studies.
引用
收藏
页数:8
相关论文
共 32 条
[31]   Field and Laboratory Evaluations of the Low-Cost Plantower Particulate Matter Sensor [J].
Zamora, Misti Levy ;
Xiong, Fulizi ;
Gentner, Drew ;
Kerkez, Branko ;
Kohrman-Glaser, Joseph ;
Koehler, Kirsten .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2019, 53 (02) :838-849
[32]   Calibration of low-cost particulate matter sensors: Model development for a multi-city epidemiological study [J].
Zusman, Marina ;
Schumacher, Cooper S. ;
Gassett, Amanda J. ;
Spalt, Elizabeth W. ;
Austin, Elena ;
Larson, Timothy V. ;
Carvlin, Graeme ;
Seto, Edmund ;
Kaufman, Joel D. ;
Sheppard, Lianne .
ENVIRONMENT INTERNATIONAL, 2020, 134