Design, Optimization and Nonlinear Response Control Analysis of the Mega Sub-Controlled Structural System (MSCSS) Under Earthquake Action

被引:17
作者
Abdulhadi, Mustapha [1 ]
Xun'an, Zhang [1 ]
Fan, Buqiao [1 ]
Moman, Muhammad [1 ]
机构
[1] Northwestern Polytech Univ, Sch Mech Civil Engn & Architecture, Xian 710071, Peoples R China
关键词
Mega sub-controlled structure system (MSCSS); optimal damper; viscous damper; control effectiveness; response control; rubber bearing; structural optimization; TUNED MASS DAMPER; SEISMIC APPLICATIONS; VIBRATION CONTROL; VISCOUS DAMPERS; BUILDINGS; FRAME; PROTECTION; PLACEMENT; MODEL; TMD;
D O I
10.1142/S179343112050013X
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The lately proposed mega sub-controlled structure (MSCSS) remarkably improved the seismic resistance ability and reduced vibration effects much more than the mega substructure (MSS). However, the controlling effectiveness and its optimization remain a significant concern. In this paper, a new configuration of MSCSS is analyzed in which viscous dampers are optimally arranged between mega-frame and substructural frame and optimal damper parameters are investigated. Also, rubber bearings are designed and introduced at the top of the additional column to ease the horizontal constraints between the additional column and mega-floor beam and improve the structural design of MSCSS, so that the structure has a larger span and further reduces the structural response. The result showed that optimal parameters of the damper and its optimal arrangement have a significant influence in the control effectiveness of MSCSS. Furthermore, the addition of a rubber bearing at the top of the additional column improves the mechanical behavior of the column and further reduces the acceleration response of both the mega-frame structure and the substructure. This paper also shows that the percentage reduction of the acceleration is more within the substructure than at the mega-frame structure. The seismic response of this structure under El Centro is less than the Taft (NE) wave and the percentage reduction is more under the Taft wave than under the El Centro wave.
引用
收藏
页数:28
相关论文
共 59 条
[1]  
Amir M. H., 2019, J EARTHQ TSUNAMI, V13
[2]   Comparison of the seismic performance of a partial mass isolation technique with conventional TMD and base-isolation systems under broad-band and narrow-band excitations [J].
Anajafi, Hamidreza ;
Medina, Ricardo A. .
ENGINEERING STRUCTURES, 2018, 158 :110-123
[3]  
[Anonymous], 2013, STAND COD SEISM DES
[4]  
[Anonymous], 2010, 50011 GB MIN HOUS UR
[5]  
[Anonymous], EARTHQ SPECTRA
[6]  
ASCE Standard/SCE, 2014, AM SOC CIVIL ENG, V41, P303
[7]   Vibration control of super tall buildings subjected to wind loads [J].
Chai, W ;
Feng, MQ .
INTERNATIONAL JOURNAL OF NON-LINEAR MECHANICS, 1997, 32 (04) :657-668
[8]  
Cuizhou Y., 2019, J EARTHQ TSUNAMI, V13
[9]   Evolutionary aseismic design and retrofit of structures with passive energy dissipation [J].
Dargush, GF ;
Sant, RS .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2005, 34 (13) :1601-1626
[10]   Design strategies of viscous dampers for seismic protection of building structures: A review [J].
De Domenico, D. ;
Ricciardi, G. ;
Takewaki, I. .
SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2019, 118 :144-165