Evaluation of mist -spraying environment on thermal sensations, thermal environment, and skin temperature under different operation modes

被引:47
作者
Oh, Wonseok [1 ]
Ooka, Ryozo [2 ]
Nakano, Junta [3 ]
Kikumoto, Hideki [2 ]
Ogawa, Osamu [4 ]
机构
[1] Univ Tokyo, Dept Architecture, Meguro Ku, 4-6-1 Komaba, Tokyo 1538505, Japan
[2] Univ Tokyo, Inst Ind Sci, Meguro Ku, 4-6-1 Komaba, Tokyo 1538505, Japan
[3] Tokai Univ, Dept Architecture, 4-1-1 Kitakaname, Hiratsuka, Kanagawa 2591292, Japan
[4] Panasonic Corp, Appliance Co, 2-3-1-2 Nojihigashi, Kusatsu, Shiga 5258555, Japan
关键词
Mist-spraying system; Outdoor environment; Thermal sensation; Thermal comfort; Skin temperature; URBAN SPACES; OUTDOOR; COMFORT; HOT; INDEX; RANGE;
D O I
10.1016/j.buildenv.2019.106484
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study aimed to evaluate an outdoor mist-spraying environment and its effect on thermal sensations, thermal environment, and skin temperature. A mist-spraying system with four modes was operated with various amounts of water spraying, both in the absence and presence of an air blowing control. Thermal sensations were reported by subjects for each operation mode and then investigated using three scales: modified thermal sensation vote (mTSV), thermal sensation vote (TSV), and comfort sensation vote (CSV). Environmental factors were compared between the outdoor and mist-spraying environments, and skin temperatures were monitored throughout the experiment. The correlation between the thermal sensations and overall skin temperatures was analyzed. The results showed that the air temperature inside the mist-spraying environment decreased ( 2.9. 1.2. C) when the mist system was operated with a larger amount of spraying water and the air temperature decreased further ( 3.6. 1.4.C) with the addition of an air blowing fan. Survey results (n 1/4 65) suggested that the mTSV changed from slightly hot to neutral, TSV changed from warm to neutral, and CSV changed from slightly uncomfortable to slightly comfort, respectively, due to the cooling effect of the mist-spraying system. The overall skin temperature decreased by approximately 0.53. C (n 1/4 65) from the baseline operation mode. Moreover, the overall skin temperature showed a higher correlation with the mTSV than with the TSV, and their correlation was higher in the mist-spraying environment compared with that in an outdoor environment.
引用
收藏
页数:14
相关论文
共 45 条
[1]   WBGT Index Revisited After 60 Years of Use [J].
Alfano, Francesca R. d'Ambrosio ;
Malchaire, Jacques ;
Palella, Boris Igor ;
Riccio, Giuseppe .
ANNALS OF OCCUPATIONAL HYGIENE, 2014, 58 (08) :955-970
[2]  
[Anonymous], 2014, CLIMATE CHANGE 2014, V80, P1
[3]  
ANSI/ASHRAE, 2013, 522012 ANSI ASHRAE
[4]   Droplet evaporation with reference to the effectiveness of water-mist cooling [J].
Barrow, H. ;
Pope, C. W. .
APPLIED ENERGY, 2007, 84 (04) :404-412
[5]  
Black DL, 1996, PROG ENERG COMBUST, V22, P267
[6]   Higher temperatures increase suicide rates in the United States and Mexico [J].
Burke, Marshall ;
Gonzalez, Felipe ;
Bayliss, Patrick ;
Heft-Neal, Sam ;
Baysan, Ceren ;
Basu, Sanjay ;
Hsiang, Solomon .
NATURE CLIMATE CHANGE, 2018, 8 (08) :723-+
[7]  
CAMP CR, 1989, T ASAE, V32, P451, DOI 10.13031/2013.31025
[8]   Outdoor thermal comfort and outdoor activities: A review of research in the past decade [J].
Chen, Liang ;
Ng, Edward .
CITIES, 2012, 29 (02) :118-125
[9]   Evaluation of meals skin temperature formulas by infrared thermography [J].
Choi, JK ;
Miki, K ;
Sagawa, S ;
Shiraki, K .
INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 1997, 41 (02) :68-75
[10]   Evaluation of cooling effects: outdoor water mist fan [J].
Farnham, Craig ;
Emura, Kazuo ;
Mizuno, Takeo .
BUILDING RESEARCH AND INFORMATION, 2015, 43 (03) :334-345