Sutureless Perceval Aortic Valve Replacement: Results of Two European Centers

被引:176
作者
Folliguet, Thierry A. [1 ]
Laborde, Francois
Zannis, Konstantinos
Ghorayeb, Gabriel
Haverich, Axel
Shrestha, Malakh
机构
[1] Inst Mutualiste Montsouris, Dept Cardiac Surg, F-75014 Paris, France
关键词
MITROFLOW PERICARDIAL BIOPROSTHESIS; STENTLESS; GUIDELINES; MORTALITY; OUTCOMES;
D O I
10.1016/j.athoracsur.2012.01.071
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The Perceval S bioprosthesis (Sorin Biomedica Cardio Srl, Sallugia, Italy) is a self-expanding valve designed to preserve aortic sinuses and sinotubular junction. We report the midterm results of a prospective, multicenter clinical study evaluating the safety and efficacy of this stented bioprosthesis in patients undergoing aortic valve replacement with or without concomitant procedures. Methods. From January 2007 to September 2011, a total of 208 high-risk patients (mean European system for cardiac operative risk evaluation: 8.7 +/- 5.3 years) received a Perceval bioprosthesis in 2 European centers. Median follow up was 10 +/- 20 months and 100% complete, and the total accumulated follow-up was 156 patient-years. Ten patients have reached a 4-year follow-up. Valve function was assessed in all patients. Results. Valve implantation resulted in significant improvement of patients' symptoms. Mean preoperative and postoperative gradients were 48.6 +/- 18.6 mm Hg and 10.4 +/- 4.3 mm Hg, respectively, and preoperative and postoperative mean effective orifice areas were 0.7 +/- 0.2 and 1.4 +/- 0.4 cm(2). Survival at 12 months was 87.1%, success of implantation was 95%, and freedom from reoperation was 96%. In hospital mortality was 2.4%. During follow-up, 9 patients (4%) required reoperation for paravalvular regurgitation; 7 early and 2 late reoperations. Mean cross-clamp time (CCT) and extracorporeal circulation time (ECT) were, respectively, 33 +/- 14 minutes and 54 +/- 24 minutes, including 45 patients who underwent surgery through ministernotomy. Concomitant coronary bypass was done in 48 patients with mean CCT 43 +/- 13 and ECT 68 +/- 25 minutes. Conclusions. Perceval sutureless is a safe bioprosthesis that can easily be implanted, including by a minimally invasive technique. It provides excellent hemodynamic with significant clinical improvement. Overall, these data confirm the safety and utility of the Perceval bioprosthesis aortic valve replacement for high-risk patients. (Ann Thorac Surg 2012;93:1483-8) (c) 2012 by The Society of Thoracic Surgeons
引用
收藏
页码:1483 / 1488
页数:6
相关论文
共 26 条
[1]  
Akins CW, 2008, ANN THORAC SURG, V85, P1490, DOI [10.1016/j.athoracsur.2007.12.082, 10.1016/j.ejcts.2007.12.055]
[2]  
Beholz S, 2007, J HEART VALVE DIS, V16, P49
[3]   Hemodynamic performance and clinical consequences of aortic valve replacement with 21-mm sized pericardial bioprostheses [J].
Boeken, U ;
Litmathe, J ;
Kurt, M ;
Feindt, P ;
Gams, E .
THORACIC AND CARDIOVASCULAR SURGEON, 2005, 53 (05) :281-284
[4]   ACC/AHA 2006 guidelines for the management of patients with valvular heart disease [J].
Bonow, Robert O. ;
Carabello, Blase A. ;
Chatterjee, Kanu ;
de Leon, Antonio C., Jr. ;
Faxon, David P. ;
Freed, Michael D. ;
Gaasch, William H. ;
Lytle, Bruce Whitney ;
Nishimura, Rick A. ;
O'Gara, Patrick T. ;
O'Rourke, Robert A. ;
Otto, Catherine M. ;
Shah, Pravin M. ;
Shanewise, Jack S. ;
Smith, Sidney C., Jr. ;
Jacobs, Alice K. ;
Adams, Cynthia D. ;
Anderson, Jeffrey L. ;
Antman, Elliott M. ;
Faxon, David P. ;
Fuster, Valentin ;
Halperin, Jonathan L. ;
Hiratzka, Loren F. ;
Hunt, Sharon A. ;
Lytle, Bruce W. ;
Nishimura, Rick ;
Page, Richard L. ;
Riegel, Barbara .
CIRCULATION, 2006, 114 (05) :E84-E231
[5]   Stentless aortic valve reoperations: A surgical challenge [J].
Borger, Michael A. ;
Prasongsukarn, Kriengchai ;
Armstrong, Susan ;
Feindel, Christopher M. ;
David, Tirone E. .
ANNALS OF THORACIC SURGERY, 2007, 84 (03) :737-744
[6]   Are stentless valves hemodynamically superior to stented valves? Long-term follow-up of a randomized trial comparing Carpentier-Edwards pericardial valve with the Toronto Stentless Porcine Valve [J].
Cohen, Gideon ;
Zagorski, Brandon ;
Christakis, George T. ;
Joyner, Campbell D. ;
Vincent, Jessica ;
Sever, Jeri ;
Harbi, Sumaya ;
Feder-Elituv, Randi ;
Moussa, Fuad ;
Goldman, Bernard S. ;
Fremes, Stephen E. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (04) :848-859
[7]   AORTIC-VALVE REPLACEMENT WITH A STENTLESS PORCINE AORTIC-VALVE - A 6-YEAR EXPERIENCE [J].
DAVID, TE ;
FEINDEL, CM ;
BOS, J ;
SUN, Z ;
SCULLY, HE ;
RAKOWSKI, H .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1994, 108 (06) :1030-1036
[8]   Aortic valve replacement with Toronto SPV bioprosthesis: Optimal patient survival but suboptimal valve durability [J].
David, Tirone E. ;
Feindel, Christopher M. ;
Bos, Joanne ;
Ivanov, Joan ;
Armstrong, Susan .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 135 (01) :19-24
[9]   Hancock II Bioprosthesis for Aortic Valve Replacement: The Gold Standard of Bioprosthetic Valves Durability? [J].
David, Tirone E. ;
Armstrong, Susan ;
Maganti, Manjula .
ANNALS OF THORACIC SURGERY, 2010, 90 (03) :775-781
[10]   Late hemodynamic and clinical outcomes of aortic valve replacement with the Carpentier-Edwards Perimount pericardial bioprosthesis [J].
Dellgren, G ;
David, TE ;
Raanani, E ;
Armstrong, S ;
Ivanov, J ;
Rakowski, H .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (01) :146-154