Bessel beam spectral-domain high-resolution optical coherence tomography with micro-optic axicon providing extended focusing range

被引:202
作者
Lee, Kye-Sung [1 ]
Rolland, Lannick P. [1 ]
机构
[1] Univ Cent Florida, CREOL, Coll Opt & Photon, Orlando, FL 32816 USA
关键词
D O I
10.1364/OL.33.001696
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Endoscopic imaging in tubular structures, such as the tracheobronchial tree, could benefit from imaging optics with an extended depth of focus (DOF) to accommodate the varying sizes of tubular structures across patients and along the tree within the same patient. Yet the extended DOF needs to be accomplished without sacrificing resolution while maintaining sufficient sensitivity and speed of imaging. In this Letter, we report on the measured resolution and sensitivity achieved with a custom-made micro-optic axicon lens designed to theoretically achieve an 8 rum DOE A measured invariant resolution of similar to 8 mu m is demonstrated across a 4 mm measured DOF using the micro-optic axicon while achieving an invariant sensitivity of similar to 80 dB with a 25 mW input power. Double-pass Bessel beam spectral-domain optical coherence tomography with an axicon micro-optic lens (i.e., < 1 mm in diameter) is, for the first time to our knowledge, demonstrated in a biological sample demonstrating invariant resolution and signal-to-noise ratio across a 4 mm measured DOF, which is compared to Gaussian beam imaging. (c) 2008 Optical Society of America.
引用
收藏
页码:1696 / 1698
页数:3
相关论文
共 8 条
[1]   High-resolution optical coherence tomography over a large depth range with an axicon lens [J].
Ding, ZH ;
Ren, HW ;
Zhao, YH ;
Nelson, JS ;
Chen, ZP .
OPTICS LETTERS, 2002, 27 (04) :243-245
[2]   Dispersion control with a Fourier-domain optical delay line in a fiber-optic imaging interferometer [J].
Lee, KS ;
Akcay, AC ;
Delemos, T ;
Clarkson, E ;
Rolland, JP .
APPLIED OPTICS, 2005, 44 (19) :4009-4022
[3]   Extended focus depth for Fourier domain optical coherence microscopy [J].
Leitgeb, R. A. ;
Villiger, M. ;
Bachmann, A. H. ;
Steinmann, L. ;
Lasser, T. .
OPTICS LETTERS, 2006, 31 (16) :2450-2452
[4]   THE AXICON - A NEW TYPE OF OPTICAL ELEMENT [J].
MCLEOD, JH .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1954, 44 (08) :592-597
[5]   Optical design of a dynamic focus catheter for high-resolution endoscopic optical coherence tomography [J].
Meemon, Panomsak ;
Lee, Kye-Sung ;
Murali, Supraja ;
Rolland, Jannick .
APPLIED OPTICS, 2008, 47 (13) :2452-2457
[6]   Invariant resolution dynamic focus OCM based on liquid crystal lens [J].
Murali, S. ;
Lee, K. S. ;
Rolland, J. P. .
OPTICS EXPRESS, 2007, 15 (24) :15854-15862
[7]   Task-based optimization and performance assessment in optical coherence imaging [J].
Rolland, J ;
O'Daniel, J ;
Akcay, C ;
DeLemos, T ;
Lee, KS ;
Cheong, KI ;
Clarkson, E ;
Chakrabarti, R ;
Ferris, R .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2005, 22 (06) :1132-1142
[8]   GRIN lens rod based probe for endoscopic spectral domain optical coherence tomography with fast dynamic focus tracking [J].
Xie, TQ ;
Guo, SG ;
Chen, ZP ;
Mukai, D ;
Brenner, M .
OPTICS EXPRESS, 2006, 14 (08) :3238-3246