Comparison of the Diagnostic Performance of Four Quantitative Myocardial Perfusion Estimation Methods Used in Cardiac MR Imaging: CE-MARC Substudy
被引:53
作者:
Biglands, John D.
[1
,3
]
Magee, Derek R.
[4
]
Sourbron, Steven P.
[1
]
Plein, Sven
[2
]
Greenwood, John P.
[2
]
Radjenovic, Aleksandra
[5
]
机构:
[1] Univ Leeds, Leeds Inst Cardiovasc & Metab Med, Div Med Phys, Leeds LS2 9JT, W Yorkshire, England
[2] Univ Leeds, Leeds Inst Cardiovasc & Metab Med, Div Cardiovasc & Diabet Res, Leeds LS2 9JT, W Yorkshire, England
[3] Leeds Teaching Hosp NHS Trust, Dept Med Phys & Engn, Leeds, W Yorkshire, England
[4] Univ Leeds, Sch Comp, Leeds, W Yorkshire, England
[5] Univ Glasgow, Coll Med Vet & Life Sci, Inst Cardiovasc & Med Sci, Glasgow, Lanark, Scotland
来源:
基金:
美国国家卫生研究院;
英国惠康基金;
关键词:
MAGNETIC-RESONANCE PERFUSION;
CORONARY-ARTERY-DISEASE;
MODEL-INDEPENDENT DECONVOLUTION;
POSITRON-EMISSION-TOMOGRAPHY;
COMPUTED-TOMOGRAPHY;
BLOOD-FLOW;
HEART-DISEASE;
QUANTIFICATION;
RESERVE;
BOLUS;
D O I:
10.1148/radiol.14140433
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Purpose: To compare the diagnostic performance of four tracer kinetic analysis methods to quantify myocardial perfusion from magnetic resonance (MR) imaging cardiac perfusion data sets in terms of their ability to lead to the diagnosis of myocardial ischemia. Materials and Methods: The study was approved by the regional ethics committee, and all patients gave written consent. A representative sample of 50 patients with suspected ischemic heart disease was retrospectively selected from the Clinical Evaluation of Magnetic Resonance Imaging in Coronary Heart Disease trial data set. Quantitative myocardial blood flow (MBF) was estimated from rest and adenosine stress MR imaging perfusion data sets by using four established methods. A matching diagnosis of both an inducible defect as assessed with single photon emission computed tomography and a luminal stenosis of 70% or more as assessed with quantitative x-ray angiography was used as the reference standard for the presence of myocardial ischemia. Diagnostic performance was evaluated with receiver operating characteristic (ROC) curve analysis for each method, with stress MBF and myocardial perfusion reserve (MPR) serving as continuous measures. Results: Area under the ROC curve with stress MBF and MPR as the outcome measures, respectively, was 0.86 and 0.92 for the Fermi model, 0.85 and 0.87 for the uptake model, 0.85 and 0.80 for the one-compartment model, and 0.87 and 0.87 for model-independent deconvolution. There was no significant difference between any of the models or between MBF and MPR, except that the Fermi model outperformed the one-compartment model if MPR was used as the outcome measure (P = .02). Conclusion: Diagnostic performance of quantitative myocardial perfusion estimates is not affected by the tracer kinetic analysis method used. (C) RSNA, 2014
引用
收藏
页码:393 / 402
页数:10