A practical design method to retrofit existing RC buildings with viscous dampers

被引:0
|
作者
Gobirahavan, R. [1 ]
Wijeyewickrema, A. C. [1 ]
机构
[1] Tokyo Inst Technol, Tokyo, Japan
关键词
DAMPING COEFFICIENTS;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Many existing RC buildings have been designed using older versions of seismic standards and such buildings may be severely damaged due to earthquakes that may occur in the future. New buildings are designed to achieve a higher seismic performance compared to existing buildings, using updated seismic design maps. Hence, seismic performance enhancement is necessary for existing buildings, corresponding to the current earthquake design level. In this study, a non-iterative design procedure is proposed to determine the mechanical characteristics of additional linear viscous dampers that are needed, to achieve an enhanced seismic performance of existing RC buildings. The enhanced seismic performance of the buildings is based on the maximum Inter-story Drift Ratio (IDR) of the buildings. The viscous damper forces are calculated relative to the story shear forces in the unretrofitted buildings. The proposed design procedure is validated by considering 4-, 8-, and 12-story RC buildings, which were designed using IBC 2009, ASCE 7-05, and ACI 318-08. Seismic performance is enhanced according to the design level of IBC 2015. PERFORM-3D (CSI 2011) software is used for modeling and analysis of the buildings.
引用
收藏
页码:983 / 992
页数:10
相关论文
共 50 条
  • [41] Response-spectrum-based design method for active base-isolated buildings with viscous dampers and hysteretic dampers
    Chen, Yinli
    Sato, Daiki
    Miyamoto, Kou
    She, Jinhua
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2022, 180
  • [42] A Displacement-Based Design Method for Seismic Retrofit of RC Buildings Using Dissipative Braces
    Ferraioli, Massimiliano
    Lavino, Angelo
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2018, 2018
  • [43] STRENGTH AND DUCTILITY TYPE SEISMIC RETROFIT TECHNIQUE FOR EXISTING PILOTIS RC BUILDINGS IN OKINAWA
    Nakada K.
    Kaneda K.
    Kuroki M.
    Matsuda M.
    Noori M.Z.
    AIJ Journal of Technology and Design, 2024, 30 (74) : 136 - 141
  • [44] The "direct five-step procedure" for the design of added viscous dampers to be inserted into existing buildings: formulation and case study
    Marra, Matteo
    Palermo, Michele
    Silvestri, Stefano
    FRONTIERS IN BUILT ENVIRONMENT, 2023, 9
  • [45] Retrofit of existing buildings for earthquake resistance
    Tan, K. H.
    Balendra, T.
    JOURNAL OF EARTHQUAKE AND TSUNAMI, 2007, 1 (02) : 161 - 169
  • [46] Risk assessment and retrofit of existing buildings
    Holmes, William T.
    Bulletin of the New Zealand National Society for Earthquake Engineering, 2000, 33 (03): : 222 - 247
  • [47] Seismic retrofit of RC buildings using self-centering PC frames with friction-dampers
    Eldin, Mohamed Nour
    Dereje, Assefa Jonathan
    Kim, Jinkoo
    ENGINEERING STRUCTURES, 2020, 208
  • [48] Using BIM to Retrofit Existing Buildings
    Khaddaj, Maggie
    Srour, Issam
    ICSDEC 2016 - INTEGRATING DATA SCIENCE, CONSTRUCTION AND SUSTAINABILITY, 2016, 145 : 1526 - 1533
  • [49] SMART BUILDINGS AND VISCOUS DAMPERS-A DESIGN ENGINEER'S PERSPECTIVE
    Taylor, Douglas P.
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2010, 19 (04): : 369 - 372
  • [50] Seismic retrofit design method for RC buildings using buckling-restrained braces and steel frames
    Sutcu, Fatih
    Takeuchi, Toru
    Matsui, Ryota
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 101 : 304 - 313