Resonant Mode Reduction in Radiofrequency Volume Coils for Ultrahigh Field Magnetic Resonance Imaging

被引:13
作者
Pang, Yong [1 ]
Xie, Zhentian [1 ]
Li, Ye [1 ]
Xu, Duan [1 ]
Vigneron, Daniel [1 ,2 ,3 ,4 ]
Zhang, Xiaoliang [1 ,2 ,3 ,4 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94158 USA
[2] UCSF UC Berkeley Joint Grad Grp Bioengn, San Francisco, CA 94720 USA
[3] UCSF UC Berkeley Joint Grad Grp Bioengn, Berkeley, CA 94720 USA
[4] Calif Inst Quantitat Biosci QB3, San Francisco, CA 94158 USA
来源
MATERIALS | 2011年 / 4卷 / 08期
关键词
Finite-Difference Time-Domain; common-mode; microstrip; Magnetic Resonance Imaging; high field; PHASED-ARRAY COIL; BIRDCAGE COIL; SURFACE COIL; HUMAN HEAD; PARALLEL EXCITATION; HUMAN BRAIN; 7; TESLA; DESIGN; MRI; FREQUENCY;
D O I
10.3390/ma4081333
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In a multimodal volume coil, only one mode can generate homogeneous Radiofrequency (RF) field for Magnetic Resonance Imaging. The existence of other modes may increase the volume coil design difficulties and potentially decreases coil performance. In this study, we introduce common-mode resonator technique to high and ultrahigh field volume coil designs to reduce the resonant mode while maintain the homogeneity of the RF field. To investigate the design method, the common-mode resonator was realized by using a microstrip line which was split along the central to become a pair of parallel transmission lines within which common-mode currents exist. Eight common-mode resonators were placed equidistantly along the circumference of a low loss dielectric cylinder to form a volume coil. Theoretical analysis and comparison between the 16-strut common-mode volume coil and a conventional 16-strut volume coil in terms of RF field homogeneity and efficiency was performed using Finite-Difference Time-Domain (FDTD) method at 298.2 MHz. MR imaging experiments were performed by using a prototype of the common-mode volume coil on a whole body 7 Tesla scanner. FDTD simulation results showed the reduced number of resonant modes of the common-mode volume coil over the conventional volume coil, while the RF field homogeneity of the two type volume coils was kept at the same level. MR imaging of a water phantom and a kiwi fruit showing the feasibility of the proposed method for simplifying the volume coil design is also presented.
引用
收藏
页码:1333 / 1344
页数:12
相关论文
共 50 条
  • [21] An optimized solenoidal head radiofrequency coil for low-field magnetic resonance imaging
    Blasiak, Barbara
    Volotovskyy, Vyacheslav
    Deng, Charlie
    Tomanek, Boguslaw
    MAGNETIC RESONANCE IMAGING, 2009, 27 (09) : 1302 - 1308
  • [22] Oval gradient coils for an open magnetic resonance imaging system with a vertical magnetic field
    Matsuzawa, Koki
    Abe, Mitsushi
    Kose, Katsumi
    Terada, Yasuhiko
    JOURNAL OF MAGNETIC RESONANCE, 2017, 278 : 51 - 59
  • [23] Dual-Channel Transverse Fields Radiofrequency Coils for 1.5 T Magnetic Resonance Imaging
    Giovannetti, Giulio
    Burov, Denis
    Alecci, Marcello
    Rollo, Rocco
    Galante, Angelo
    SENSORS, 2024, 24 (07)
  • [24] High-Field Magnetic Resonance Imaging
    Kangarlu, Alayar
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2009, 19 (01) : 113 - +
  • [25] Investigation of high-resolution functional magnetic resonance imaging by means of surface and array radiofrequency coils at 7 T
    van der Zwaag, Wietske
    Marques, Jose P.
    Hergt, Martin
    Gruetter, Rolf
    MAGNETIC RESONANCE IMAGING, 2009, 27 (08) : 1011 - 1018
  • [26] Sodium Radiofrequency Coils for Magnetic Resonance: From Design to Applications
    Giovannetti, Giulio
    Flori, Alessandra
    Martini, Nicola
    Francischello, Roberto
    Aquaro, Giovanni Donato
    Pingitore, Alessandro
    Frijia, Francesca
    ELECTRONICS, 2021, 10 (15)
  • [27] Multiple slot modules for high field magnetic resonance imaging array coils
    Alkandari, Dheyaa
    Bosshard, John C.
    Huang, Chung-Huan
    Wright, Steven M.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (06) : 2485 - 2498
  • [28] Application of Ultrahigh Field Magnetic Resonance Imaging in the Treatment of Brain Tumors: A Meta-Analysis
    Barrett, Thomas F.
    Sarkiss, Christopher A.
    Dyvorne, Hadrien A.
    Lee, James
    Balchandani, Priti
    Shrivastava, Raj K.
    WORLD NEUROSURGERY, 2016, 86 : 450 - 465
  • [29] Magnetic resonance imaging and radiofrequency ablations
    Dickfeld T.
    Herzschrittmachertherapie & Elektrophysiologie, 2007, 18 (3): : 147 - 156
  • [30] Wireless, customizable coaxially shielded coils for magnetic resonance imaging
    Wu, Ke
    Zhu, Xia
    Anderson, Stephan W.
    Zhang, Xin
    SCIENCE ADVANCES, 2024, 10 (24):