Resonant Mode Reduction in Radiofrequency Volume Coils for Ultrahigh Field Magnetic Resonance Imaging

被引:13
作者
Pang, Yong [1 ]
Xie, Zhentian [1 ]
Li, Ye [1 ]
Xu, Duan [1 ]
Vigneron, Daniel [1 ,2 ,3 ,4 ]
Zhang, Xiaoliang [1 ,2 ,3 ,4 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94158 USA
[2] UCSF UC Berkeley Joint Grad Grp Bioengn, San Francisco, CA 94720 USA
[3] UCSF UC Berkeley Joint Grad Grp Bioengn, Berkeley, CA 94720 USA
[4] Calif Inst Quantitat Biosci QB3, San Francisco, CA 94158 USA
来源
MATERIALS | 2011年 / 4卷 / 08期
关键词
Finite-Difference Time-Domain; common-mode; microstrip; Magnetic Resonance Imaging; high field; PHASED-ARRAY COIL; BIRDCAGE COIL; SURFACE COIL; HUMAN HEAD; PARALLEL EXCITATION; HUMAN BRAIN; 7; TESLA; DESIGN; MRI; FREQUENCY;
D O I
10.3390/ma4081333
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In a multimodal volume coil, only one mode can generate homogeneous Radiofrequency (RF) field for Magnetic Resonance Imaging. The existence of other modes may increase the volume coil design difficulties and potentially decreases coil performance. In this study, we introduce common-mode resonator technique to high and ultrahigh field volume coil designs to reduce the resonant mode while maintain the homogeneity of the RF field. To investigate the design method, the common-mode resonator was realized by using a microstrip line which was split along the central to become a pair of parallel transmission lines within which common-mode currents exist. Eight common-mode resonators were placed equidistantly along the circumference of a low loss dielectric cylinder to form a volume coil. Theoretical analysis and comparison between the 16-strut common-mode volume coil and a conventional 16-strut volume coil in terms of RF field homogeneity and efficiency was performed using Finite-Difference Time-Domain (FDTD) method at 298.2 MHz. MR imaging experiments were performed by using a prototype of the common-mode volume coil on a whole body 7 Tesla scanner. FDTD simulation results showed the reduced number of resonant modes of the common-mode volume coil over the conventional volume coil, while the RF field homogeneity of the two type volume coils was kept at the same level. MR imaging of a water phantom and a kiwi fruit showing the feasibility of the proposed method for simplifying the volume coil design is also presented.
引用
收藏
页码:1333 / 1344
页数:12
相关论文
共 50 条
  • [1] Dielectric Waveguides for Ultrahigh Field Magnetic Resonance Imaging
    Bluemink, Johanna J.
    Raaijmakers, Alexander J. E.
    Koning, Wouter
    Andreychenko, Anna
    Rivera, Debra S.
    Luijten, Peter R.
    Klomp, Dennis W. J.
    van den Berg, Cornelis A. T.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (04) : 1314 - 1324
  • [2] High-field magnetic resonance imaging using solenoid radiofrequency coils
    Vegh, Viktor
    Glaeser, Philipp
    Maillet, Donald
    Cowin, Gary J.
    Reutens, David C.
    MAGNETIC RESONANCE IMAGING, 2012, 30 (08) : 1177 - 1185
  • [3] A Brief Review of Radiofrequency Coils for Cardiac Magnetic Resonance Imaging and Spectroscopy
    Giovannetti, Giulio
    Flori, Alessandra
    Positano, Vincenzo
    De Marchi, Daniele
    Menichetti, Luca
    Pingitore, Alessandro
    CURRENT MEDICAL IMAGING REVIEWS, 2018, 14 (05) : 695 - 703
  • [4] Trap Design for Insertable Second-Nuclei Radiofrequency Coils for Magnetic Resonance Imaging and Spectroscopy
    Dabirzadeh, Arash
    McDougall, Mary Preston
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2009, 35B (03) : 121 - 132
  • [5] Self-decoupled radiofrequency coils for magnetic resonance imaging
    Yan, Xinqiang
    Gore, John C.
    Grissom, William A.
    NATURE COMMUNICATIONS, 2018, 9
  • [6] High Field Cardiac Magnetic Resonance Imaging A Case for Ultrahigh Field Cardiac Magnetic Resonance
    Niendorf, Thoralf
    Schulz-Menger, Jeanette
    Paul, Katharina
    Huelnhagen, Till
    Ferrari, Victor A.
    Hodge, Russell
    CIRCULATION-CARDIOVASCULAR IMAGING, 2017, 10 (06)
  • [7] Birdcage volume coils and magnetic resonance imaging: a simple experiment for students
    Vincent, Dwight E.
    Wang, Tianhao
    Magyar, Thalia A. K.
    Jacob, Peni I.
    Buist, Richard
    Martin, Melanie
    JOURNAL OF BIOLOGICAL ENGINEERING, 2017, 11
  • [8] Kerker Effect in Ultrahigh-Field Magnetic Resonance Imaging
    Dubois, Marc
    Leroi, Lisa
    Raolison, Zo
    Abdeddaim, Redha
    Antonakakis, Tryfon
    de Rosny, Julien
    Vignaud, Alexandre
    Sabouroux, Pierre
    Georget, Elodie
    Larrat, Benoit
    Tayeb, Gerard
    Bonod, Nicolas
    Amadon, Alexis
    Mauconduit, Franck
    Poupon, Cyril
    Le Bihan, Denis
    Enoch, Stefan
    PHYSICAL REVIEW X, 2018, 8 (03):
  • [9] Magnetic Resonance Imaging at Ultrahigh Fields
    Ugurbil, Kamil
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (05) : 1364 - 1379
  • [10] Birdcage volume coils and magnetic resonance imaging: a simple experiment for students
    Dwight E. Vincent
    Tianhao Wang
    Thalia A. K. Magyar
    Peni I. Jacob
    Richard Buist
    Melanie Martin
    Journal of Biological Engineering, 11