Comparison of safety and efficacy between silicone and polypropyIene Ahmed glaucoma valves in refractory glaucoma

被引:52
作者
Law, SK [1 ]
Nguyen, A [1 ]
Coleman, AL [1 ]
Caprioli, J [1 ]
机构
[1] Univ Calif Los Angeles, Sch Med, Jules Stein Eye Inst, Los Angeles, CA 90095 USA
关键词
D O I
10.1016/j.ophtha.2005.04.012
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To compare the safety and efficacy of polypropylene and silicone Ahmed glaucoma valves (AGVs) over 1 year of follow-up. Design: Retrospective comparative study. Participants: Fifty consecutive patients with polypropylene and 49 consecutive patients with silicone AGV implantation. Methods: Our hospital instituted a formulary conversion of the glaucoma aqueous drainage device from polypropylene to silicone AGVs in January 2003. We reviewed the polypropylene AGVs within 7 months before and the silicone AGVs within 7 months after the date of conversion performed on patients with glaucoma refractory to medical treatment and filtering procedures, without previous drainage devices or cyclodestructive procedures, and with a minimum of 12 months' follow-up. Surgical success was defined as an intraocular pressure (IOP) reduction of >= 20% and a final IOP of > 5 and < 22 mmHg, without additional surgical intervention for IOP control, loss of light perception, or serious complications. Main Outcome Measures: The 2 groups were compared for IOP control, visual outcome, complication rate, and surgical success rate. Results: Significant IOP reductions occurred after polypropylene AGV implantation (from 32.4 +/- 11.3 mmHg to 16.5 +/- 6.9 mmHg, P < 0.0001) and silicone AGV implantation (from 32.6 +/- 12.6 mmHg to 14.7 +/- 6.9 mmHg, P < 0.0001). The silicone group had a lower mean IOP than the polypropylene group at all postoperative visits, but the differences were significant only at 3 months postoperatively (P = 0.014). In addition, the silicone group was associated with a rate of insufficient IOP control as the reason of failure (IOP of >= 22 mmHg or IOP reduction of < 20%) lower (4.1 %) than that of the polypropylene group (20.0%, P = 0.015), but a rate of non-tube related serious complications (16.3%) higher than that of the polypropylene AGV (4.0%, P = 0.042). Conclusion: After 1 year of follow-up, the silicone AGV is at least as effective as the polypropylene AGV in IOP reduction but may be associated with a higher rate of complications. These differences are important for surgeons converting to use of the silicone AGV in patients with glaucoma refractory to other forms of treatment.
引用
收藏
页码:1514 / 1520
页数:7
相关论文
共 20 条
  • [1] Comparison of different biomaterials for glaucoma drainage devices - Part 2
    Ayyala, RS
    Michelini-Norris, B
    Flores, A
    Haller, E
    Margo, CE
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2000, 118 (08) : 1081 - 1084
  • [2] Ayyala RS, 1999, ARCH OPHTHALMOL-CHIC, V117, P233
  • [3] Bhatia Lini S., 2004, International Ophthalmology Clinics, V44, P123, DOI 10.1097/00004397-200404410-00014
  • [4] INITIAL CLINICAL-EXPERIENCE WITH THE AHMED GLAUCOMA VALVE IMPLANT
    COLEMAN, AL
    HILL, R
    WILSON, MR
    CHOPLIN, N
    KOTASNEUMANN, R
    TAM, M
    BACHARACH, J
    PANEK, WC
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1995, 120 (01) : 23 - 31
  • [5] Feldman RM, 1997, J GLAUCOMA, V6, P10
  • [6] Characteristics of glaucoma drainage implants during dynamic and steady-state flow conditions
    Francis, BA
    Cortes, A
    Chen, J
    Alvarado, JA
    [J]. OPHTHALMOLOGY, 1998, 105 (09) : 1708 - 1714
  • [7] Prevention of early postoperative hypotony by partial ligation of silicone tube in Ahmed glaucoma valve implantation
    Kee, C
    [J]. JOURNAL OF GLAUCOMA, 2001, 10 (06) : 466 - 469
  • [8] Retinal complications after aqueous shunt surgical procedures for glaucoma
    Law, SK
    Kalenak, JW
    Connor, TB
    Pulido, JS
    Han, DP
    Mieler, WF
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1996, 114 (12) : 1473 - 1480
  • [9] Evaluation of the hypertensive phase after insertion of the Ahmed Glaucoma Valve
    Nouri-Mahdavi, K
    Caprioli, J
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 136 (06) : 1001 - 1008
  • [10] Baerveldt-350 implant versus Ahmed valve for refractory glaucoma - A case-controlled comparison
    Syed, HM
    Law, SK
    Nam, SH
    Li, G
    Caprioli, J
    Coleman, A
    [J]. JOURNAL OF GLAUCOMA, 2004, 13 (01) : 38 - 45