Assessment of High-Power Electronic Nicotine Delivery System as an Alternative Aerosol Device for Terbutaline Delivery

被引:5
作者
Chaoui, Mariam [1 ,2 ]
Chevrel, Sophie [1 ]
Perinel-Ragey, Sophie [2 ,3 ,4 ]
Prevot, Nathalie [2 ,3 ,5 ]
Pourchez, Jeremie [2 ]
机构
[1] Univ Jean Monnet, Univ Lyon, Ctr CIS, INSERM,Mines St Etienne,U1059 Sainbiose, F-42023 St Etienne, France
[2] INSERM, U1059, F-42023 St Etienne, France
[3] Univ Jean Monnet, Fac Med, St Etienne, France
[4] CHU St Etienne, Med Surg Intens Care Unit, F-42055 St Etienne, France
[5] CHU St Etienne, Dept Nucl Med, F-42055 St Etienne, France
关键词
Aerosol particle size distribution; Cascade impactors; Electronic cigarette; Pharmaceutical formulation; Pulmonary delivery; Terbutaline; SIZE DISTRIBUTION; PARTICLE; IMPACT;
D O I
10.1007/s11095-022-03187-0
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Purpose The performance of new-generation high-power electronic nicotine delivery system (ENDS) for the administration of inhaled terbutaline was assessed. Methods The formulation of e-liquid was carried out using terbutaline in combination with 1, 3- propanediol. Several terbutaline concentrations (from 0.3125 to 2.500 mg / mL) and power levels (from 15 to 35 W) were assessed using a box type ENDS. The respirable drug dose was determined using a Glass Twin Impinger and quantified by liquid chromatography coupled with a UV-detector. The Next Generation Impactor and the Dekati Low Pressure Impactor were used to measure the aerosol particle size distribution in drug mass. The results were compared with a jet nebulizer (Cirrus TM 2) similar to the usual clinical conditions (2 mL at [terbutaline] of 2.5 mg / mL). Results The optimal conditions to maximize terbutaline delivery using ENDS are a drug concentration at 1 mg/mL, and a power level at 30 W, to reach a respirable dose of 8.73 +/- 0.90 mu g/puff. By contrast, during a 5 min nebulization, the respirable dose of terbutaline was 1040 +/- 33 mu g whatever the cascade impactors and the aerosol devices used. The mass median aerodynamic diameter (MMAD) remains similar for jet nebulizer and ENDS in the 1.74-2.07 mu m range. Conclusion Compared to the jet nebulizer, a same respirable dose of terbutaline at the same range of aerosol size distribution was delivered by ENDS if 120 puffs were performed. The ENDS can be considered as an alternative aerosol device for terbutaline delivery.
引用
收藏
页码:587 / 597
页数:11
相关论文
共 20 条
[1]   Patients' practices and experiences of using nebuliser therapy in the management of COPD at home [J].
Alhaddad, B. ;
Smith, F. J. ;
Robertson, T. ;
Watman, G. ;
Taylor, K. M. G. .
BMJ OPEN RESPIRATORY RESEARCH, 2015, 2 (01) :1-9
[2]   Repurposing drugs as inhaled therapies in asthma [J].
Anderson, Sandra D. .
ADVANCED DRUG DELIVERY REVIEWS, 2018, 133 :19-33
[3]  
Banon I., 2017, VAPOR MED DISPENSING, P13
[4]   Physical and chemical assessment of 1,3 Propanediol as a potential substitute of propylene glycol in refill liquid for electronic cigarettes [J].
Bertrand, Philippe ;
Bonnarme, Vincent ;
Piccirilli, Antoine ;
Ayrault, Philippe ;
Lemee, Laurent ;
Frapper, Gilles ;
Pourchez, Jeremie .
SCIENTIFIC REPORTS, 2018, 8
[5]   Delivery of beclomethasone dipropionate nanosuspensions with an electronic cigarette [J].
Casula, Luca ;
Sinico, Chiara ;
Valenti, Donatella ;
Pini, Elena ;
Pireddu, Rosa ;
Schlich, Michele ;
Lai, Francesco ;
Fadda, Anna Maria .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2021, 596
[6]   Handling forces for the use of different inhaler devices [J].
Ciciliani, Anna-Maria ;
Langguth, Peter ;
Wachtel, Herbert .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2019, 560 :315-321
[7]   Device selection and outcomes of aerosol therapy: Evidence-based guidelines [J].
Dolovich, MB ;
Ahrens, RC ;
Hess, DR ;
Anderson, P ;
Dhand, R ;
Rau, JL ;
Smaldone, GC ;
Guyatt, G .
CHEST, 2005, 127 (01) :335-371
[8]   Particle size measurements for the Space-Chamber metered dose inhaler holding chamber compared with aerochamber and metered dose inhaler alone [J].
Finlay, WH ;
Zuberbuhler, P ;
Mandl, M .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1997, 10 (03) :213-219
[9]   Influential parameters on particle concentration and size distribution in the mainstream of e-cigarettes [J].
Fuoco, F. C. ;
Buonanno, G. ;
Stabile, L. ;
Vigo, P. .
ENVIRONMENTAL POLLUTION, 2014, 184 :523-529
[10]   A Novel Nebulizer-Based Continuous Flow Reactor: Introducing the Use of Pneumatically Generated Aerosols for Highly Productive Photooxidations [J].
Ioannou, Georgios I. ;
Montagnon, Tamsyn ;
Kalaitzakis, Dimitris ;
Pergantis, Spiros A. ;
Vassilikogiannakis, Georgios .
CHEMPHOTOCHEM, 2017, 1 (05) :173-177