Sex differences in active tibialis anterior stiffness evaluated using supersonic shear imaging

被引:27
作者
Souron, Robin [1 ]
Bordat, Florian [1 ]
Farabet, Adrien [1 ]
Belli, Alain [1 ]
Feasson, Leonard [1 ,3 ]
Nordez, Antoine [2 ]
Lapole, Thomas [1 ]
机构
[1] Univ Lyon, UJM St Etienne, Lab Interuniv Biol Motricite, EA 7424, F-42023 St Etienne, France
[2] Univ Nantes, UFR STAPS, Lab Movement Interact Performance, EA 4334, Nantes, France
[3] CHU St Etienne, Ctr Referent Malad Neuromusculaires Rares Rhone A, Unite Myol, St Etienne, France
关键词
Elastography; Supersonic shear imaging; Muscle stiffness; Sex; Tibialis anterior; MAGNETIC-RESONANCE ELASTOGRAPHY; ELASTIC COMPONENT STIFFNESS; MUSCLE-TENDON COMPLEX; TRANSIENT ELASTOGRAPHY; MECHANICAL-PROPERTIES; PASSIVE PARTS; EXTENSIBILITY; MODULUS; FLEXORS; PLANTAR;
D O I
10.1016/j.jbiomech.2016.08.008
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This study aimed to evaluate the sex difference in active muscle stiffness of the tibialis anterior muscle (TA) through shear modulus measurements performed using supersonic shear imaging (SSI) technique. Twenty-five women and twenty-one men participated in this study. Joint torque, electromyographic (EMG) activity and shear modulus were measured during two sets of submaximal dorsiflexions performed at 20, 30, 40, 50 and 60% of maximal voluntary contraction (MVC) in a random order. The first set was devoted to the EMG recordings and the second set was devoted to the elastographic measurements. For each set, subjects performed three 5-s trials at each level of submaximal voluntary contraction. Stiffness indexes were calculated as the slopes of the linear regressions established between shear modulus and joint torque (SITORQUE) or estimated TA EMG levels (SIEMG). In the present study, no sex effect was reported for SITORQUE, SIEMG (p = 0.76 and p=0.86, respectively), and shear modulus measured at various contraction levels. The results highlight that men and women presented similar TA active stiffness indexes determined using SSI. Regardless of sex, this result suggests similar intrinsic stiffness for the contracting TA. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3534 / 3537
页数:4
相关论文
共 36 条
[1]   Evaluation of healthy and diseased muscle with magnetic resonance elastography [J].
Basford, JR ;
Jenkyn, TR ;
An, KN ;
Ehman, RL ;
Heers, G ;
Kaufman, KR .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2002, 83 (11) :1530-1536
[2]   Supersonic shear imaging: A new technique for soft tissue elasticity mapping [J].
Bercoff, J ;
Tanter, M ;
Fink, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (04) :396-409
[3]   Comparison of triceps surae structural stiffness and material modulus across sex [J].
Blackburn, JT ;
Padua, DA ;
Weinhold, PS ;
Guskiewicz, KM .
CLINICAL BIOMECHANICS, 2006, 21 (02) :159-167
[4]   Sex comparison of extensibility, passive, and active stiffness of the knee flexors [J].
Blackburn, JT ;
Riemann, BL ;
Padua, DA ;
Guskiewicz, KM .
CLINICAL BIOMECHANICS, 2004, 19 (01) :36-43
[5]   STORE AND RECOIL OF ELASTIC ENERGY IN SLOW AND FAST TYPES OF HUMAN SKELETAL-MUSCLES [J].
BOSCO, C ;
TIHANYI, J ;
KOMI, PV ;
FEKETE, G ;
APOR, P .
ACTA PHYSIOLOGICA SCANDINAVICA, 1982, 116 (04) :343-349
[6]   Lower extremity stiffness: implications for performance and injury [J].
Butler, RJ ;
Crowell, HP ;
Davis, IM .
CLINICAL BIOMECHANICS, 2003, 18 (06) :511-517
[7]   Length and activation dependent variations in muscle shear wave speed [J].
Chernak, L. A. ;
DeWall, R. J. ;
Lee, K. S. ;
Thelen, D. G. .
PHYSIOLOGICAL MEASUREMENT, 2013, 34 (06) :713-721
[8]   Ultrasound elastography for musculoskeletal applications [J].
Drakonaki, E. E. ;
Allen, G. M. ;
Wilson, D. J. .
BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1019) :1435-1445
[9]   THE RELATION BETWEEN STIFFNESS AND FILAMENT OVERLAP IN STIMULATED FROG-MUSCLE FIBERS [J].
FORD, LE ;
HUXLEY, AF ;
SIMMONS, RM .
JOURNAL OF PHYSIOLOGY-LONDON, 1981, 311 (FEB) :219-249
[10]   Gender differences in both active and passive parts of the plantar flexors series elastic component stiffness and geometrical parameters of the muscle-tendon complex [J].
Foure, Alexandre ;
Cornu, Christophe ;
McNair, Peter J. ;
Nordez, Antoine .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2012, 30 (05) :707-712