Dual-energy MDCT: Comparison of pulmonary artery enhancement on dedicated CT pulmonary angiography, routine and low contrast volume studies

被引:45
|
作者
Godoy, Myrna C. B. [1 ,2 ]
Heller, Samantha L. [2 ]
Naidich, David P. [2 ]
Assadourian, Bernard [2 ]
Leidecker, Christianne [3 ]
Schmidt, Bernhard [4 ]
Vlahos, Ioannis [2 ,5 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Diagnost Radiol, Houston, TX 77030 USA
[2] NYU, Dept Radiol, Langone Med Ctr, New York, NY 10016 USA
[3] Siemens Med Solut, Malvern, PA USA
[4] Siemens Healthcare, Forchheim, Germany
[5] St Georges Hosp NHS Trust, London, England
关键词
CTPA; CT pulmonary angiography; Pulmonary embolism; Dual energy CT; Dual source CT; KILOVOLTAGE SETTINGS; COMPUTED-TOMOGRAPHY; INITIAL-EXPERIENCE; EMBOLISM; REPAIR;
D O I
10.1016/j.ejrad.2009.12.030
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was (a) to compare arterial enhancement in simultaneously acquired high- and low-kilovoltage images; and (b) to determine whether low tube-voltage imaging would permit PE evaluation on routine chest CT studies or CTPA studies performed with a low volume of contrast media. Materials and methods: We compared 20 CTPA studies (CTPA group), 20 routine thoracic CT studies (RT group) and 10 CTPA studies performed with reduced volume of contrast media (RC group). HU values were measured in all groups at 80 kVp and 140 kVp images in multiple pulmonary arterial segments bilaterally. The diagnostic quality of the central and peripheral vascular enhancement and the image noise were evaluated at both energies using a five-point scale. Results: For all patients, the mean CT attenuation values were greater at 80 kVp than 140 kVp images (p < 0.001). At 80 kVp, CTPA group attenuation values were greater than RT group (p = 0.03) with a similar trend at 140 kVp (p = 0.08). At both 140 kVp and 80 kVp, CTPA group attenuation values were greater than RC group (p = 0.02 and p = 0.03, respectively). Qualitative analysis showed that at 140 kVp CTPA studies had better global image quality scores than RT (p = 0.003) and RC (p = 0.001) groups. However, at 80 kVp, there was no significant difference of global image quality between CTPA and the other groups (p = 0.4 and p = 0.5, respectively). Although measurable image noise was greater at 80 kVp than 140 kVp (p < 0.001), qualitative analysis revealed lower image noise at 80 kVp images. Conclusion: DECT at 80 kVp increases arterial enhancement in both CTPA and routine studies. For routine studies this results in central and peripheral enhancement quality equivalent to that of CTPA studies. Low tube-voltage imaging allows marked contrast volume reduction for CTPA. In selected cases, satisfactory lower radiation dose CT might be achievable using lower kVp imaging alone. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E11 / E17
页数:7
相关论文
共 50 条
  • [31] Pulmonary Perfused Blood Volume with Dual-Energy CT as Surrogate for Pulmonary Perfusion Assessed with Dynamic Multidetector CT
    Fuld, Matthew K.
    Halaweish, Ahmed F.
    Haynes, Susan E.
    Divekar, Abhay A.
    Guo, Junfeng
    Hoffman, Eric A.
    RADIOLOGY, 2013, 267 (03) : 747 - 756
  • [32] Optimization of Contrast Material Delivery for Dual-Energy Computed Tomography Pulmonary Angiography in Patients With Suspected Pulmonary Embolism
    Nance, John W., Jr.
    Henzler, Thomas
    Meyer, Mathias
    Apfaltrer, Paul
    Braunagel, Margarita
    Krissak, Radko
    Schoepf, Uwe J.
    Schoenberg, Stefan O.
    Fink, Christian
    INVESTIGATIVE RADIOLOGY, 2012, 47 (01) : 78 - 84
  • [33] Feasibility of low contrast volume and low injection flow rate in CT pulmonary angiography
    Lee, Wan Chin
    Poon, Jun Kai
    Siah, Jacqueline Jin Hui
    Chong, Mei Choo
    Lai, Christopher
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2025, 56 (01)
  • [34] Comparison of Dual- and Single-Source Dual-Energy CT for Diagnosis of Acute Pulmonary Artery Embolism
    Petritsch, Bernhard
    Pannenbecker, Pauline
    Weng, Andreas Max
    Veldhoen, Simon
    Grunz, Jan-Peter
    Bley, Thorsten Alexander
    Kosmala, Aleksander
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2021, 193 (04): : 427 - 436
  • [35] Dual-energy CT in pulmonary vascular disease
    Vlahos, Ioannis
    Jacobsen, Megan C.
    Godoy, Myrna C.
    Stefanidis, Konstantinos
    Layman, Rick R.
    BRITISH JOURNAL OF RADIOLOGY, 2022, 95 (1129):
  • [36] Evaluation of computer-aided detection and dual energy software in detection of peripheral pulmonary embolism on dual-energy pulmonary CT angiography
    Lee, Choong Wook
    Seo, Joon Beom
    Song, Jae-Woo
    Kim, Mi-Young
    Lee, Ha Young
    Park, Yang Shin
    Chae, Eun Jin
    Jang, Yu Mi
    Kim, Namkug
    Krauss, Bernard
    EUROPEAN RADIOLOGY, 2011, 21 (01) : 54 - 62
  • [37] Evaluation of computer-aided detection and dual energy software in detection of peripheral pulmonary embolism on dual-energy pulmonary CT angiography
    Choong Wook Lee
    Joon Beom Seo
    Jae-Woo Song
    Mi-Young Kim
    Ha Young Lee
    Yang Shin Park
    Eun Jin Chae
    Yu Mi Jang
    Namkug Kim
    Bernard Krauss
    European Radiology, 2011, 21 : 54 - 62
  • [38] Low contrast volume dual-energy CT of the chest: Quantitative and qualitative assessment
    Digumarthy, Subba R.
    Singh, Ramandeep
    Rastogi, Shivam
    Otrakji, Alexi
    Homayounieh, Fatemeh
    Zhang, Eric W.
    McDermott, Shaunagh
    Kalra, Mannudeep K.
    CLINICAL IMAGING, 2021, 69 : 305 - 310
  • [39] Assessment of Calcified Carotid Plaque Volume: Comparison of Contrast-Enhanced Dual-Energy CT Angiography and Native Single-Energy CT
    Watanabe, Yoshiyuki
    Nakazawa, Tetsuro
    Higashi, Masahiro
    Itoh, Toshihide
    Naito, Hiroaki
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) : W796 - W799
  • [40] Dual-Energy CT Angiography for Detection of Pulmonary Emboli: Incremental Benefit of Iodine Maps
    Weidman, Elizabeth K.
    Plodkowski, Andrew J.
    Halpenny, Darragh F.
    Hayes, Sara A.
    Perez-Johnston, Rocio
    Zheng, Junting
    Moskowitz, Chava
    Ginsberg, Michelle S.
    RADIOLOGY, 2018, 289 (02) : 546 - 553