Dual-energy MDCT: Comparison of pulmonary artery enhancement on dedicated CT pulmonary angiography, routine and low contrast volume studies

被引:45
作者
Godoy, Myrna C. B. [1 ,2 ]
Heller, Samantha L. [2 ]
Naidich, David P. [2 ]
Assadourian, Bernard [2 ]
Leidecker, Christianne [3 ]
Schmidt, Bernhard [4 ]
Vlahos, Ioannis [2 ,5 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Diagnost Radiol, Houston, TX 77030 USA
[2] NYU, Dept Radiol, Langone Med Ctr, New York, NY 10016 USA
[3] Siemens Med Solut, Malvern, PA USA
[4] Siemens Healthcare, Forchheim, Germany
[5] St Georges Hosp NHS Trust, London, England
关键词
CTPA; CT pulmonary angiography; Pulmonary embolism; Dual energy CT; Dual source CT; KILOVOLTAGE SETTINGS; COMPUTED-TOMOGRAPHY; INITIAL-EXPERIENCE; EMBOLISM; REPAIR;
D O I
10.1016/j.ejrad.2009.12.030
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was (a) to compare arterial enhancement in simultaneously acquired high- and low-kilovoltage images; and (b) to determine whether low tube-voltage imaging would permit PE evaluation on routine chest CT studies or CTPA studies performed with a low volume of contrast media. Materials and methods: We compared 20 CTPA studies (CTPA group), 20 routine thoracic CT studies (RT group) and 10 CTPA studies performed with reduced volume of contrast media (RC group). HU values were measured in all groups at 80 kVp and 140 kVp images in multiple pulmonary arterial segments bilaterally. The diagnostic quality of the central and peripheral vascular enhancement and the image noise were evaluated at both energies using a five-point scale. Results: For all patients, the mean CT attenuation values were greater at 80 kVp than 140 kVp images (p < 0.001). At 80 kVp, CTPA group attenuation values were greater than RT group (p = 0.03) with a similar trend at 140 kVp (p = 0.08). At both 140 kVp and 80 kVp, CTPA group attenuation values were greater than RC group (p = 0.02 and p = 0.03, respectively). Qualitative analysis showed that at 140 kVp CTPA studies had better global image quality scores than RT (p = 0.003) and RC (p = 0.001) groups. However, at 80 kVp, there was no significant difference of global image quality between CTPA and the other groups (p = 0.4 and p = 0.5, respectively). Although measurable image noise was greater at 80 kVp than 140 kVp (p < 0.001), qualitative analysis revealed lower image noise at 80 kVp images. Conclusion: DECT at 80 kVp increases arterial enhancement in both CTPA and routine studies. For routine studies this results in central and peripheral enhancement quality equivalent to that of CTPA studies. Low tube-voltage imaging allows marked contrast volume reduction for CTPA. In selected cases, satisfactory lower radiation dose CT might be achievable using lower kVp imaging alone. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E11 / E17
页数:7
相关论文
共 15 条
  • [1] Improved vascular opacification in cerebral computed tomography angiography with 80 kVp
    Bahner, ML
    Bengel, A
    Brix, G
    Zuna, I
    Kauczor, HU
    Delorme, S
    [J]. INVESTIGATIVE RADIOLOGY, 2005, 40 (04) : 229 - 234
  • [2] Clinical Utility of Dual-Energy CT in the Evaluation of Solitary Pulmonary Nodules: Initial Experience
    Chae, Eun Jin
    Song, Jae-Woo
    Seo, Joon Beom
    Krauss, Bernhard
    Jang, Yu Mi
    Song, Koun-Sik
    [J]. RADIOLOGY, 2008, 249 (02) : 671 - 681
  • [3] Abdominal Aorta: Evaluation with Dual-Source Dual-Energy Multidetector CT after Endovascular Repair of Aneurysms-Initial Observations
    Chandarana, Hersh
    Godoy, Myrna C. B.
    Vlahos, Ioannis
    Graser, Anno
    Babb, James
    Leidecker, Christianne
    Macari, Michael
    [J]. RADIOLOGY, 2008, 249 (02) : 692 - 700
  • [4] Multi-detector row CT angiography of the brain at various kilovoltage settings
    Ertl-Wagner, BB
    Hoffmann, RT
    Bruning, R
    Herrmann, K
    Snyder, B
    Blume, JD
    Reiser, MF
    [J]. RADIOLOGY, 2004, 231 (02) : 528 - 535
  • [5] Dual-Energy CT Angiography of the Lung in Patients with Suspected Pulmonary Embolism: Initial Results
    Fink, C.
    Johnson, T. R.
    Michaely, H. J.
    Morhard, D.
    Becker, C.
    Reiser, M.
    Nikolaou, K.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2008, 180 (10): : 879 - 883
  • [6] First performance evaluation of a dual-source CT (DSCT) system
    Flohr, TG
    McCollough, CH
    Bruder, H
    Petersilka, M
    Gruber, K
    Süss, C
    Grasruck, M
    Stierstorfer, K
    Krauss, B
    Raupach, R
    Primak, AN
    Küttner, A
    Achenbach, S
    Becker, C
    Kopp, A
    Ohnesorge, BM
    [J]. EUROPEAN RADIOLOGY, 2006, 16 (02) : 256 - 268
  • [7] Basic Principles and Postprocessing Techniques of Dual-Energy CT: Illustrated by Selected Congenital Abnormalities of the Thorax
    Godoy, Myrna C. B.
    Naidich, David P.
    Marchiori, Edson
    Assadourian, Bernard
    Leidecker, Christianne
    Schmidt, Bernhard
    Vlahos, Ioannis
    [J]. JOURNAL OF THORACIC IMAGING, 2009, 24 (02) : 152 - 159
  • [8] GRASER A, 2008, EUR RADIOL, V252, P433
  • [9] Material differentiation by dual energy CT: initial experience
    Johnson, Thorsten R. C.
    Krauss, Bernhard
    Sedlmair, Martin
    Grasruck, Michael
    Bruder, Herbert
    Morhard, Dominik
    Fink, Christian
    Weckbach, Sabine
    Lenhard, Miriam
    Schmidt, Bernhard
    Flohr, Thomas
    Reiser, Maximilian F.
    Becker, Christoph R.
    [J]. EUROPEAN RADIOLOGY, 2007, 17 (06) : 1510 - 1517
  • [10] Management of suspected acute pulmonary embolism in the era of CT angiography: A statement from the Fleischner Society
    Remy-Jardin, Martine
    Pistolesi, Massimo
    Goodman, Lawrence R.
    Gefter, Warren B.
    Gottschalk, Alexander
    Mayo, John R.
    Sostman, H. Dirk
    [J]. RADIOLOGY, 2007, 245 (02) : 315 - 329