Synchronization software for automation in anesthesia

被引:3
作者
Bressan, Nadja [1 ]
Castro, Ana [1 ]
Bras, Susana [1 ]
Oliveira, Helder P.
Ribeiro, Lenio
Ferreira, David A.
Antunes, Luis
Amorim, Pedro
Nunes, Catarina S. [1 ]
机构
[1] Univ Porto, Fac Ciencias, Dept Matemat Aplicada, P-4169007 Oporto, Portugal
来源
2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16 | 2007年
关键词
D O I
10.1109/IEMBS.2007.4353537
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This work presents the development of a software for data acquisition and control (ASYS) on a clinical setup. Similar to the industrial Supervisory Control And Data Acquisition (SCADA) the software assembles a Target Controlled Infusion (TCI) monitoring and supervisory control data in real time from devices in a surgical room. The software is not a full controller since the TCI systems comprehend permanent interaction from the anesthesiologist Based on pharmacokinetic models, the effect-site and plasma concentrations can be related with the drug dose infused and vice versa. The software determines the infusion rates of the drug which are given as commands to the infusion pumps. This software provides the anesthesiologist with a trustworthy tool for managing a safe and balanced anesthesia. Since it also incorporates the acquisition and display of patients brain signals.
引用
收藏
页码:5298 / 5301
页数:4
相关论文
共 11 条
[1]  
Absalom A., 2005, OVERVIEW TARGET CONT
[2]   Evaluation and optimisation of a target-controlled infusion system for administering propofol to dogs as part of a total intravenous anaesthetic technique during dental surgery [J].
Beths, T ;
Glen, JB ;
Reid, J ;
Monteiro, AM ;
Nolan, AM .
VETERINARY RECORD, 2001, 148 (07) :198-203
[3]   A manual slide rule for target-controlled infusion of propofol:: Development and evaluation [J].
Bruhn, J ;
Bouillon, TW ;
Röpcke, H ;
Hoeft, A .
ANESTHESIA AND ANALGESIA, 2003, 96 (01) :142-147
[4]   Target-controlled drug delivery - Progress toward an intravenous "vaporizer" and automated anesthetic administration [J].
Egan, TD .
ANESTHESIOLOGY, 2003, 99 (05) :1214-1219
[5]   Pharmacokinetics and pharmacodynamics of remifentanil .2. Model application [J].
Minto, CF ;
Schnider, TW ;
Shafer, SL .
ANESTHESIOLOGY, 1997, 86 (01) :24-33
[6]  
Nunes CS, 2006, LECT NOTES ARTIF INT, V4252, P1248
[7]   Regular clinical use Bispectral Index monitoring may result in lighter depth of anesthesia as reflected in average higher Bispectral Index values [J].
Nunes, CS ;
Ferreira, DA ;
Antunes, LM ;
Amorim, P .
ANESTHESIOLOGY, 2005, 103 (06) :1320-1321
[8]  
NUNES CS, 2006, MODELLING CONTROL BI, P447
[9]   Target-controlled versus manually-controlled infusion of propofol for direct laryngoscopy and bronchoscopy [J].
Passot, S ;
Servin, F ;
Allary, R ;
Pascal, J ;
Prades, JM ;
Auboyer, C ;
Molliex, S .
ANESTHESIA AND ANALGESIA, 2002, 94 (05) :1212-1216
[10]   MANUAL COMPARED WITH TARGET-CONTROLLED INFUSION OF PROPOFOL [J].
RUSSELL, D ;
WILKES, MP ;
HUNTER, SC ;
GLEN, JB ;
HUTTON, P ;
KENNY, GNC .
BRITISH JOURNAL OF ANAESTHESIA, 1995, 75 (05) :562-566