MRI quality assurance based on 3D FLAIR brain images
被引:5
|
作者:
Peltonen, Juha I.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Helsinki, Helsinki Univ Hosp, HUS Med Imaging Ctr, Radiol, POB 340, FI-00029 Helsinki, Finland
Aalto Univ, Sch Sci, Dept Neurosci & Biomed Engn, POB 12200, FI-00076 Espoo, FinlandUniv Helsinki, Helsinki Univ Hosp, HUS Med Imaging Ctr, Radiol, POB 340, FI-00029 Helsinki, Finland
Peltonen, Juha I.
[1
,2
]
Makela, Teemu
论文数: 0引用数: 0
h-index: 0
机构:
Univ Helsinki, Helsinki Univ Hosp, HUS Med Imaging Ctr, Radiol, POB 340, FI-00029 Helsinki, Finland
Univ Helsinki, Dept Phys, POB 64, FI-00014 Helsinki, FinlandUniv Helsinki, Helsinki Univ Hosp, HUS Med Imaging Ctr, Radiol, POB 340, FI-00029 Helsinki, Finland
Makela, Teemu
[1
,3
]
Salli, Eero
论文数: 0引用数: 0
h-index: 0
机构:
Univ Helsinki, Helsinki Univ Hosp, HUS Med Imaging Ctr, Radiol, POB 340, FI-00029 Helsinki, FinlandUniv Helsinki, Helsinki Univ Hosp, HUS Med Imaging Ctr, Radiol, POB 340, FI-00029 Helsinki, Finland
Salli, Eero
[1
]
机构:
[1] Univ Helsinki, Helsinki Univ Hosp, HUS Med Imaging Ctr, Radiol, POB 340, FI-00029 Helsinki, Finland
[2] Aalto Univ, Sch Sci, Dept Neurosci & Biomed Engn, POB 12200, FI-00076 Espoo, Finland
[3] Univ Helsinki, Dept Phys, POB 64, FI-00014 Helsinki, Finland
ObjectiveQuality assurance (QA) of magnetic resonance imaging (MRI) often relies on imaging phantoms with suitable structures and uniform regions. However, the connection between phantom measurements and actual clinical image quality is ambiguous. Thus, it is desirable to measure objective image quality directly from clinical images.Materials and methodsIn this work, four measurements suitable for clinical image QA were presented: image resolution, contrast-to-noise ratio, quality index and bias index. The methods were applied to a large cohort of clinical 3D FLAIR volumes over a test period of 9.5 months. The results were compared with phantom QA. Additionally, the effect of patient movement on the presented measures was studied.ResultsA connection between the presented clinical QA methods and scanner performance was observed: the values reacted to MRI equipment breakdowns that occurred during the study period. No apparent correlation with phantom QA results was found. The patient movement was found to have a significant effect on the resolution and contrast-to-noise ratio values.DiscussionQA based on clinical images provides a direct method for following MRI scanner performance. The methods could be used to detect problems, and potentially reduce scanner downtime. Furthermore, with the presented methodologies comparisons could be made between different sequences and imaging settings. In the future, an online QA system could recognize insufficient image quality and suggest an immediate re-scan.
机构:
INRA, UMR Physiol Reprod & Comportements UMR 85, F-37380 Nouzilly, France
CNRS, UMR 7247, F-37380 Nouzilly, France
Univ Tours, F-37041 Tours, FranceINRA, UMR Physiol Reprod & Comportements UMR 85, F-37380 Nouzilly, France
Ella, Arsene
Keller, Matthieu
论文数: 0引用数: 0
h-index: 0
机构:
INRA, UMR Physiol Reprod & Comportements UMR 85, F-37380 Nouzilly, France
CNRS, UMR 7247, F-37380 Nouzilly, France
Univ Tours, F-37041 Tours, FranceINRA, UMR Physiol Reprod & Comportements UMR 85, F-37380 Nouzilly, France
机构:
Ohio State Univ, Ctr Cognit & Behav Brain Imaging, Columbus, OH 43210 USAOhio State Univ, Ctr Cognit & Behav Brain Imaging, Columbus, OH 43210 USA
Wang, Jinghua
He, Lili
论文数: 0引用数: 0
h-index: 0
机构:
Cincinnati Childrens Hosp Med Ctr, Perinatal Inst, Dept Pediat, Cincinnati, OH 45229 USAOhio State Univ, Ctr Cognit & Behav Brain Imaging, Columbus, OH 43210 USA
He, Lili
Zheng, Hairong
论文数: 0引用数: 0
h-index: 0
机构:
Chinese Acad Sci, Shenzhen Inst Adv Technol, Paul C Lauterbur Res Ctr Biomed Imaging, Shenzhen, Peoples R ChinaOhio State Univ, Ctr Cognit & Behav Brain Imaging, Columbus, OH 43210 USA
Zheng, Hairong
Lu, Zhong-Lin
论文数: 0引用数: 0
h-index: 0
机构:
Ohio State Univ, Ctr Cognit & Behav Brain Imaging, Columbus, OH 43210 USAOhio State Univ, Ctr Cognit & Behav Brain Imaging, Columbus, OH 43210 USA
机构:
Ain Shams Univ, Fac Computers & Informat Sci, Dept Basic Sci, POB 11566, Cairo, EgyptAin Shams Univ, Fac Computers & Informat Sci, Dept Basic Sci, POB 11566, Cairo, Egypt
El-Torky, Dina Mohammed Sherif
Al-Berry, Maryam Nabil
论文数: 0引用数: 0
h-index: 0
机构:
Ain Shams Univ, Fac Computers & Informat Sci, Dept Basic Sci, POB 11566, Cairo, EgyptAin Shams Univ, Fac Computers & Informat Sci, Dept Basic Sci, POB 11566, Cairo, Egypt
Al-Berry, Maryam Nabil
Salem, Mohammed Abdel-Megeed
论文数: 0引用数: 0
h-index: 0
机构:
Ain Shams Univ, Fac Computers & Informat Sci, Dept Basic Sci, POB 11566, Cairo, Egypt
German Univ Cairo, Fac Media Engn & Technol, Cairo, EgyptAin Shams Univ, Fac Computers & Informat Sci, Dept Basic Sci, POB 11566, Cairo, Egypt
Salem, Mohammed Abdel-Megeed
Roushdy, Mohamed Ismail
论文数: 0引用数: 0
h-index: 0
机构:
Ain Shams Univ, Fac Computers & Informat Sci, Dept Basic Sci, POB 11566, Cairo, EgyptAin Shams Univ, Fac Computers & Informat Sci, Dept Basic Sci, POB 11566, Cairo, Egypt