MRI quality assurance based on 3D FLAIR brain images

被引:5
|
作者
Peltonen, Juha I. [1 ,2 ]
Makela, Teemu [1 ,3 ]
Salli, Eero [1 ]
机构
[1] Univ Helsinki, Helsinki Univ Hosp, HUS Med Imaging Ctr, Radiol, POB 340, FI-00029 Helsinki, Finland
[2] Aalto Univ, Sch Sci, Dept Neurosci & Biomed Engn, POB 12200, FI-00076 Espoo, Finland
[3] Univ Helsinki, Dept Phys, POB 64, FI-00014 Helsinki, Finland
关键词
Magnetic resonance imaging; Quality assurance; Quality control; Computer-assisted image analysis; MAGNETIC-RESONANCE IMAGES; SUBARACHNOID HEMORRHAGE; SPATIAL-RESOLUTION; SEQUENCES; OPTIMIZATION; SENSITIVITY; PREVALENCE; CONTRAST;
D O I
10.1007/s10334-018-0699-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveQuality assurance (QA) of magnetic resonance imaging (MRI) often relies on imaging phantoms with suitable structures and uniform regions. However, the connection between phantom measurements and actual clinical image quality is ambiguous. Thus, it is desirable to measure objective image quality directly from clinical images.Materials and methodsIn this work, four measurements suitable for clinical image QA were presented: image resolution, contrast-to-noise ratio, quality index and bias index. The methods were applied to a large cohort of clinical 3D FLAIR volumes over a test period of 9.5 months. The results were compared with phantom QA. Additionally, the effect of patient movement on the presented measures was studied.ResultsA connection between the presented clinical QA methods and scanner performance was observed: the values reacted to MRI equipment breakdowns that occurred during the study period. No apparent correlation with phantom QA results was found. The patient movement was found to have a significant effect on the resolution and contrast-to-noise ratio values.DiscussionQA based on clinical images provides a direct method for following MRI scanner performance. The methods could be used to detect problems, and potentially reduce scanner downtime. Furthermore, with the presented methodologies comparisons could be made between different sequences and imaging settings. In the future, an online QA system could recognize insufficient image quality and suggest an immediate re-scan.
引用
收藏
页码:689 / 699
页数:11
相关论文
共 50 条
  • [21] Comparison of 3D Cube FLAIR with 2D FLAIR for Multiple Sclerosis Imaging at 3 Tesla
    Patzig, M.
    Burke, M.
    Brueckmann, H.
    Fesl, G.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (05): : 484 - 488
  • [22] 3D POLYMER GEL DOSIMETRY FOR QUALITY ASSURANCE IN RADIATION THERAPY
    Ceberg, Sofie
    Adliene, Diana
    Mattsson, Soren
    MEDICAL PHYSICS IN THE BALTIC STATES, 2017, : 30 - 35
  • [23] Quality assurance of serial 3D image registration, fusion, and segmentation
    Sharpe, Michael
    Brock, Kristy K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01): : S33 - S37
  • [24] Classification of Pancreatic Tumors based on MRI Images using 3D Convolutional Neural Networks
    Chen, Xuan
    Chen, Yufei
    Ma, Chao
    Liu, Xianhui
    Tang, Xin
    ISICDM 2018: PROCEEDINGS OF THE 2ND INTERNATIONAL SYMPOSIUM ON IMAGE COMPUTING AND DIGITAL MEDICINE, 2018, : 92 - 96
  • [25] A feature-based solution for 3D registration of CT and MRI images of human knee
    Zheng, Jingjie
    Ji, Zhenyan
    Yu, Kuangdi
    An, Qin
    Guo, Zhiming
    Wu, Zuyi
    SIGNAL IMAGE AND VIDEO PROCESSING, 2015, 9 (08) : 1815 - 1824
  • [26] A feature-based solution for 3D registration of CT and MRI images of human knee
    Jingjie Zheng
    Zhenyan Ji
    Kuangdi Yu
    Qin An
    Zhiming Guo
    Zuyi Wu
    Signal, Image and Video Processing, 2015, 9 : 1815 - 1824
  • [27] 3D Brain MRI Reconstruction based on 2D Super-Resolution Technology
    Zhang Hongtao
    Shinomiya, Yuki
    Yoshida, Shinichi
    2020 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2020, : 18 - 23
  • [28] Quality Assessment of 3D Synthesized Images Based on Textural and Structural Distortion Estimation
    Alvi, Hafiz Muhammad Usama Hassan
    Farid, Muhammad Shahid
    Khan, Muhammad Hassan
    Grzegorzek, Marcin
    APPLIED SCIENCES-BASEL, 2021, 11 (06):
  • [29] Brain Imaging Quality Assurance: How to Acquire the Best Brain Images Possible
    Grabher, Barbara J.
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2019, 47 (01) : 13 - 20
  • [30] 3D active surfaces for liver segmentation in multisequence MRI images
    Bereciartua, Arantza
    Picon, Artzai
    Galdran, Adrian
    Iriondo, Pedro
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2016, 132 : 149 - 160