MRI quality assurance based on 3D FLAIR brain images

被引:5
|
作者
Peltonen, Juha I. [1 ,2 ]
Makela, Teemu [1 ,3 ]
Salli, Eero [1 ]
机构
[1] Univ Helsinki, Helsinki Univ Hosp, HUS Med Imaging Ctr, Radiol, POB 340, FI-00029 Helsinki, Finland
[2] Aalto Univ, Sch Sci, Dept Neurosci & Biomed Engn, POB 12200, FI-00076 Espoo, Finland
[3] Univ Helsinki, Dept Phys, POB 64, FI-00014 Helsinki, Finland
关键词
Magnetic resonance imaging; Quality assurance; Quality control; Computer-assisted image analysis; MAGNETIC-RESONANCE IMAGES; SUBARACHNOID HEMORRHAGE; SPATIAL-RESOLUTION; SEQUENCES; OPTIMIZATION; SENSITIVITY; PREVALENCE; CONTRAST;
D O I
10.1007/s10334-018-0699-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveQuality assurance (QA) of magnetic resonance imaging (MRI) often relies on imaging phantoms with suitable structures and uniform regions. However, the connection between phantom measurements and actual clinical image quality is ambiguous. Thus, it is desirable to measure objective image quality directly from clinical images.Materials and methodsIn this work, four measurements suitable for clinical image QA were presented: image resolution, contrast-to-noise ratio, quality index and bias index. The methods were applied to a large cohort of clinical 3D FLAIR volumes over a test period of 9.5 months. The results were compared with phantom QA. Additionally, the effect of patient movement on the presented measures was studied.ResultsA connection between the presented clinical QA methods and scanner performance was observed: the values reacted to MRI equipment breakdowns that occurred during the study period. No apparent correlation with phantom QA results was found. The patient movement was found to have a significant effect on the resolution and contrast-to-noise ratio values.DiscussionQA based on clinical images provides a direct method for following MRI scanner performance. The methods could be used to detect problems, and potentially reduce scanner downtime. Furthermore, with the presented methodologies comparisons could be made between different sequences and imaging settings. In the future, an online QA system could recognize insufficient image quality and suggest an immediate re-scan.
引用
收藏
页码:689 / 699
页数:11
相关论文
共 50 条
  • [1] MRI quality assurance based on 3D FLAIR brain images
    Juha I. Peltonen
    Teemu Mäkelä
    Eero Salli
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2018, 31 : 689 - 699
  • [2] Improving the image quality of 3D FLAIR with a spiral MRI technique
    Li, Zhiqiang
    Pipe, James G.
    Ooi, Melvyn B.
    Kuwabara, Michael
    Karis, John P.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (01) : 170 - 177
  • [3] Pitfalls of 3D FLAIR Brain Imaging: A Prospective Comparison with 2D FLAIR
    Kakeda, Shingo
    Korogi, Yukunori
    Hiai, Yasuhiro
    Ohnari, Norihiro
    Sato, Toru
    Hirai, Toshinori
    ACADEMIC RADIOLOGY, 2012, 19 (10) : 1225 - 1232
  • [4] Assessment of sedated pediatric brain with 3D-FLAIR sequence at 3T MRI
    Ozcan, Umit Aksoy
    Isik, Ugur
    Ozpinar, Alp
    Baykan, Nigar
    Dincer, Alp
    BRAIN & DEVELOPMENT, 2015, 37 (05) : 495 - 500
  • [5] Rule-Based Quality Assurance Tool for 3D Buildings
    Turunen, Alpo
    25TH AGILE CONFERENCE ON GEOGRAPHIC INFORMATION SCIENCE ARTIFICIAL INTELLIGENCE IN THE SERVICE OF GEOSPATIAL TECHNOLOGIES, 2022, 3
  • [6] Brain Image and Lesions Registration and 3D Reconstruction in Dicom MRI Images
    Loizou, Christos P.
    Papacharalambous, Christos
    Samaras, Giorgos
    Kyriacou, Efthyvoulos
    Kasparis, Takis
    Pantziaris, Marios
    Eracleous, Eleni
    Pattichis, Constantinos S.
    2017 IEEE 30TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS), 2017, : 419 - 422
  • [7] Automated Testing and Quality Assurance of 3D Printing/3D Printed Hardware Assessment for quality assurance and cybersecurity purposes
    Straub, Jeremy
    2016 IEEE AUTOTESTCON PROCEEDINGS, 2016,
  • [8] A 3D MRI-based atlas of a lizard brain
    Hoops, Daniel
    Desfilis, Ester
    Ullmann, Jeremy F. P.
    Janke, Andrew L.
    Stait-Gardner, Timothy
    Devenyi, Gabriel A.
    Price, William S.
    Medina, Loreta
    Whiting, Martin J.
    Keogh, J. Scott
    JOURNAL OF COMPARATIVE NEUROLOGY, 2018, 526 (16) : 2511 - 2547
  • [9] Automatic segmentation of cerebral white matter hyperintensities using only 3D FLAIR images
    Simoes, Rita
    Moenninghoff, Christoph
    Dlugaj, Martha
    Weimar, Christian
    Wanke, Isabel
    van Walsum, Anne-Marie van Cappellen
    Slump, Cornelis
    MAGNETIC RESONANCE IMAGING, 2013, 31 (07) : 1182 - 1189
  • [10] Quality assurance for 3D conformal radiation therapy
    Purdy, JA
    Harms, WB