Calcium ion-selective electrodes under galvanostatic current control

被引:50
作者
Bedlechowicz, I
Sokalski, T
Lewenstam, A
Maj-zurawska, M
机构
[1] Warsaw Univ, Dept Chem, PL-02093 Warsaw, Poland
[2] Abo Akad Univ, Proc Chem Grp, SF-20500 Turku, Finland
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2005年 / 108卷 / 1-2期
关键词
ion-selective electrodes (ISEs); detection limit; galvanostatic current; plasticizer;
D O I
10.1016/j.snb.2004.12.092
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ion-selective electrodes (ISEs) are in many respects ideal sensors for use in the analysis of industrial and environmental samples. Thus, in recent years, the advantages that they offer have led to their adoption in a wide range of applications. Ion-selective electrodes offer several significant advantages over other techniques in the field. These are: insensitivity to sample color, viscosity or suspended solids, rapid response to changes in determinant concentration, and possible use in a very wide concentration range. A further advantage of analytical method involving ISE is that they are relatively simple, and cheap to develop, set up and run. One of the possibilities to improve the detection limit of ISE is to control the ion transport through the ion-selective membrane with a galvanostatic current. Passing nanoampere-level direct currents across the membrane can control ion fluxes through the membrane, which can obscure the determination at low concentration level. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:836 / 839
页数:4
相关论文
共 30 条
  • [1] APPLICABILITY OF THE PHASE-BOUNDARY POTENTIAL MODEL TO THE MECHANISTIC UNDERSTANDING OF SOLVENT POLYMERIC MEMBRANE-BASED ION-SELECTIVE ELECTRODES
    BAKKER, E
    NAGELE, M
    SCHALLER, U
    PRETSCH, E
    [J]. ELECTROANALYSIS, 1995, 7 (09) : 817 - 822
  • [2] Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics
    Bakker, E
    Buhlmann, P
    Pretsch, E
    [J]. CHEMICAL REVIEWS, 1997, 97 (08) : 3083 - 3132
  • [3] Bedlechowicz W, 2002, J ELECTROANAL CHEM, V537, P111
  • [4] DONNAN EXCLUSION FAILURE IN LOW ANION SITE DENSITY MEMBRANES CONTAINING VALINOMYCIN
    BUCK, RP
    TOTH, K
    GRAF, E
    HORVAI, G
    PUNGOR, E
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 223 (1-2): : 51 - 66
  • [5] Rational design of potentiometric trace level ion sensors.: A Ag+-selective electrode with a 100 ppt detection limit
    Ceresa, A
    Radu, A
    Peper, S
    Bakker, E
    Pretsch, E
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (16) : 4027 - 4036
  • [6] Influence of key parameters on the lower detection limit and response function of solvent polymeric membrane ion-selective electrodes
    Ceresa, A
    Sokalski, T
    Pretsch, E
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 501 (1-2): : 70 - 76
  • [7] Potentiometric polymeric membrane electrodes for measurement of environmental samples at trace levels:: New requirements for selectivities and measuring protocols, and comparison with ICPMS
    Ceresa, A
    Bakker, E
    Hattendorf, B
    Günther, D
    Pretsch, E
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (02) : 343 - 351
  • [8] ION-TRANSPORT IN MODEL MEMBRANES WITH MAGNESIUM AND CALCIUM SELECTIVITY INDUCED BY ELECTRICALLY CHARGED IONOPHORES
    ERNE, D
    MORF, WE
    ARVANITIS, S
    CIMERMAN, Z
    AMMANN, D
    SIMON, W
    [J]. HELVETICA CHIMICA ACTA, 1979, 62 (04) : 994 - 1006
  • [9] Spectroscopic method for the determination of the ionic site concentration in solvent polymeric membranes and membrane plasticizers
    Gyurcsányi, RE
    Lindner, E
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (16) : 4060 - 4068
  • [10] Direct evidence of ionic fluxes across ion selective membranes:: A scanning electrochemical microscopic and potentiometric study
    Gyurcsányi, RE
    Pergel, E
    Nagy, R
    Kapui, I
    Lan, BTT
    Tóth, K
    Bitter, I
    Lindner, E