Relation between impedance and electrode temperature during radiofrequency catheter ablation of accessory pathways and atrioventricular nodal reentrant tachycardia

被引:12
作者
Nsah, E [1 ]
Berger, R [1 ]
Rosenthal, L [1 ]
Hui, R [1 ]
Ramza, B [1 ]
Jumrussirikul, P [1 ]
Lawrence, JH [1 ]
Tomaselli, G [1 ]
Kass, D [1 ]
Calkins, H [1 ]
机构
[1] Johns Hopkins Hosp, Baltimore, MD 21287 USA
关键词
D O I
10.1016/S0002-8703(98)70130-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives Impedance monitoring has been proposed as a method to assess the adequacy of tissue heating during catheter ablation procedures. The purpose of this study was to evaluate the relation among initial impedance, Fall in impedance, and electrode temperature during catheter ablation procedures. Methods and Results Data from 248 applications of radiofrequency energy in 45 consecutive patients (26 with accessory pathways and 19 with atrioventricular nodal reentrant tachycardia) referred for catheter ablation were analyzed. The initial impedance was higher during ablation of accessory pathways than during atrioventricular nodal reentrant tachycardia (116 +/- 66 versus 106 +/- 80 Omega, P < .001). In both groups, a significant correlation was observed between the initial impedance and temperature (R = 0.98, P < .001). After accounting for differences between patients and ablation targets, an even closer correlation was observed (accessory pathways: R = 0.95, P < .0001; atrioventricular nodal reentrant tachycardia: R = 0.94, P < .0001). Conclusion These data suggest that monitoring of the initial impedance and the fall in impedance during ablation procedures may provide clinically valuable information to assess the efficacy of tissue heating and lesion formation.
引用
收藏
页码:844 / 851
页数:8
相关论文
共 29 条
  • [1] ASSESSMENT OF EFFECTS OF A RADIOFREQUENCY ENERGY-FIELD AND THERMISTOR LOCATION IN AN ELECTRODE CATHETER ON THE ACCURACY OF TEMPERATURE-MEASUREMENT
    BLOUIN, LT
    MARCUS, FI
    LAMPE, L
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (05): : 807 - 813
  • [2] DETERMINANTS OF IMPEDANCE DURING RADIOFREQUENCY CATHETER ABLATION IN HUMANS
    BORGANELLI, M
    ELATASSI, R
    LEON, A
    KALBFLEISCH, SJ
    CALKINS, H
    MORADY, F
    LANGBERG, JJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (12) : 1095 - 1097
  • [3] HIGH-FREQUENCY ALTERNATING-CURRENT ABLATION OF AN ACCESSORY PATHWAY IN HUMANS
    BORGGREFE, M
    BUDDE, T
    PODCZECK, A
    BREITHARDT, G
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (03) : 576 - 582
  • [4] TEMPERATURE MONITORING DURING RADIOFREQUENCY CATHETER ABLATION PROCEDURES USING CLOSED-LOOP CONTROL
    CALKINS, H
    PRYSTOWSKY, E
    CARLSON, M
    KLEIN, LS
    SAUL, JP
    KAY, GN
    DAILEY, S
    EPSTEIN, A
    PLUMB, V
    WHARTON, M
    KANTER, R
    SORRENTINO, R
    GREENFIELD, RA
    WALSH, E
    WALDO, A
    BIBLO, L
    JOHNSON, N
    LIEBERMAN, R
    ROSENBAUM, D
    HUANG, SKS
    MITTLEMAN, RS
    WAGSHAL, AB
    GREENE, T
    LIEM, B
    LAUER, M
    SUNG, R
    YOUNG, C
    EVANS, J
    CASE, C
    HACKETT, K
    MILES, W
    ZIPES, D
    LAWRENCE, J
    TOMASELLI, G
    BERGER, R
    [J]. CIRCULATION, 1994, 90 (03) : 1279 - 1286
  • [5] DIAGNOSIS AND CURE OF THE WOLFF-PARKINSON-WHITE SYNDROME OR PAROXYSMAL SUPRAVENTRICULAR TACHYCARDIAS DURING A SINGLE ELECTROPHYSIOLOGIC TEST
    CALKINS, H
    SOUSA, J
    ELATASSI, R
    ROSENHECK, S
    DEBUITLEIR, M
    KOU, WH
    KADISH, AH
    LANGBERG, JJ
    MORADY, F
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (23) : 1612 - 1618
  • [6] CONTROLLED DESTRUCTION AND TEMPERATURE DISTRIBUTIONS IN BIOLOGICAL TISSUES SUBJECTED TO MONOACTIVE ELECTROCOAGULATION
    EREZ, A
    SHITZER, A
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1980, 102 (01): : 42 - 49
  • [7] RADIOFREQUENCY CATHETER ABLATION FOR THE TREATMENT OF HUMAN TYPE-1 ATRIAL-FLUTTER - IDENTIFICATION OF A CRITICAL ZONE IN THE REENTRANT CIRCUIT BY ENDOCARDIAL MAPPING TECHNIQUES
    FELD, GK
    FLECK, RP
    CHEN, PS
    BOYCE, K
    BAHNSON, TD
    STEIN, JB
    CALISI, CM
    IBARRA, M
    [J]. CIRCULATION, 1992, 86 (04) : 1233 - 1240
  • [8] GROGAN JEW, 1987, J AM COLL CARDIOL, V9, pA95
  • [9] HAINES D, 1993, CIRCULATION, V88, P1
  • [10] OBSERVATIONS ON ELECTRODE-TISSUE INTERFACE TEMPERATURE AND EFFECT ON ELECTRICAL-IMPEDANCE DURING RADIOFREQUENCY ABLATION OF VENTRICULAR MYOCARDIUM
    HAINES, DE
    VEROW, AF
    [J]. CIRCULATION, 1990, 82 (03) : 1034 - 1038