Long-term outcomes of pericardial strip versus prosthetic ring annuloplasty for secondary tricuspid regurgitation by a minimally invasive approach

被引:3
|
作者
Nasso, Giuseppe [1 ]
Di Bari, Nicola [1 ]
Santarpino, Giuseppe [1 ,2 ,3 ]
Moscarelli, Marco [1 ]
Brigiani, Mario Siro [1 ]
Condello, Ignazio [1 ]
Bartolomucci, Francesco [1 ]
Speziale, Giuseppe [1 ]
机构
[1] Anthea Hosp, Dept Cardiovasc Surg, GVM Care & Res, Via Camillo Rosalba 35-38, Bari, Italy
[2] Magna Graecia Univ Catanzaro, Dept Expt & Clin Med, Catanzaro, Italy
[3] Paracelsus Med Univ, Dept Cardiac Surg, Nurnberg, Germany
关键词
Pericardial strip annuloplasty; Secondary tricuspid regurgitation; Autologous pericardial strip; Tricuspid annuloplasty; MITRAL-VALVE REPAIR; EUROPEAN ASSOCIATION; GUIDELINES; MORTALITY; SURGERY; SOCIETY;
D O I
10.1186/s13019-021-01723-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background This study was conducted to compare the outcomes of prosthetic ring versus autologous pericardial strip for the treatment of functional tricuspid regurgitation during left-sided valve surgery by minimally invasive approach. Methods From January 2008 and July 2016, autologous pericardial strip (group P-TAP) was used in 109 patients, and prosthetic ring (group R-TAP) in 115 patients. The primary outcomes were long-term overall survival, development of patch degeneration, and significant tricuspid regurgitation recurrence. The second outcome was the assessment of right ventricular functional parameters. Results Operative mortality was 1 case (0.9%) in the R-TAP group. At the time of hospital discharge only one patient (0.9%) in the R-TAP group had grade III+ tricuspid regurgitation, and none had grade IV+. Mean follow-up was 94.1 +/- 24.5 months. Mild and moderate tricuspid regurgitation recurrence was 3.7% and 4.5% (P-TAP vs. R-TAP groups, p = 0.99). Severe regurgitation was observed in 1.8% of cases only in the R-TAP group (p = 0.49). There were no reoperations. Late mortality was 3.7% and 5.4% (P-TAP vs. R-TAP groups, p = 0.75). Freedom from death, all causes, were comparable among groups (log-rank p = 0.45). There were no statistically significant differences between two groups in TAPSE, left ventricular end-diastolic diameter, left ventricular ejection fraction, and left atrial diameter. Conclusions Tricuspid annuloplasty using an autologous pericardial strip in patients undergoing minimally invasive surgery is associated to similar long results (survival, late tricuspid regurgitation, and functional echocardiographic parameters) than annuloplasty with a prosthetic ring. In particular, the pericardial strip over time does not develop any degeneration or retraction.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Long-term outcomes of pericardial strip versus prosthetic ring annuloplasty for secondary tricuspid regurgitation by a minimally invasive approach
    Giuseppe Nasso
    Nicola Di Bari
    Giuseppe Santarpino
    Marco Moscarelli
    Mario Siro Brigiani
    Ignazio Condello
    Francesco Bartolomucci
    Giuseppe Speziale
    Journal of Cardiothoracic Surgery, 16
  • [2] Long-Term Outcomes of Tricuspid Annuloplasty for Functional Tricuspid Regurgitation Associated with Degenerative Mitral Regurgitation: Suture Annuloplasty Versus Ring Annuloplasty Using a Flexible Band
    Murashita, Takashi
    Okada, Yukikatsu
    Kanemitsu, Hideo
    Fukunaga, Naoto
    Konishi, Yasunobu
    Nakamura, Ken
    Koyama, Tadaaki
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 20 (06) : 1026 - 1033
  • [3] Long-Term Outcomes of Suture vs. Ring Tricuspid Annuloplasty for Functional Tricuspid Regurgitation
    Hata, Hiroki
    Fujita, Tomoyuki
    Miura, Sayaka
    Shimahara, Yusuke
    Kume, Yuta
    Matsumoto, Yorihiko
    Yamashita, Kizuku
    Kobayashi, Junjiro
    CIRCULATION JOURNAL, 2017, 81 (10) : 1432 - 1438
  • [4] Mid-Term Outcomes of Suture Annuloplasty Versus Ring Annuloplasty for Functional Tricuspid Regurgitation
    Hata, Hiroki
    Fujita, Tomoyuki
    Shimahara, Yusuke
    Sato, Shunsuke
    Kobayashi, Junjiro
    CARDIOLOGY, 2014, 128 (02) : 120 - 120
  • [5] Eight-Year Outcomes of Tricuspid Annuloplasty Using Autologous Pericardial Strip for Functional Tricuspid Regurgitation
    Chang, Byung-Chul
    Song, Suk-Won
    Lee, Sak
    Yoo, Kyung-Jong
    Kang, Meyun-Shick
    Chung, Namsik
    ANNALS OF THORACIC SURGERY, 2008, 86 (05): : 1485 - 1493
  • [6] Long-Term Results of Tricuspid Annuloplasty Using MC3 Ring for Functional Tricuspid Regurgitation
    Choi, Jae Woong
    Kim, Kyung Hwan
    Kim, Sue Hyun
    Yeom, Sang Yoon
    Hwang, Ho Young
    Kim, Ki-Bong
    CIRCULATION JOURNAL, 2018, 82 (09) : 2358 - 2363
  • [7] Long-term outcomes of rigid ring versus De Vega annuloplasty for functional tricuspid regurgitation: A propensity score-matcnmg analysis
    Sohn, Suk Ho
    Kim, Kyung Hwan
    Lee, Yeiwon
    Choi, Jae Woong
    Hwang, Ho Young
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2021, 161 (05): : 1788 - +
  • [8] Long-term outcomes of rigid ring versus De Vega annuloplasty for functional tricuspid regurgitation: A propensity score-matching analysis
    Boateng, Percy
    Kim, Kyung Hwan
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2021, 161 (05): : 1797 - 1798
  • [9] Comparison of outcomes of tricuspid annuloplasty with 3D-rigid versus flexible prosthetic ring for functional tricuspid regurgitation secondary to rheumatic mitral valve disease
    Wang, Haiping
    Liu, Xiancheng
    Wang, Xin
    Lv, Zhenqian
    Liu, Xiaojun
    Xu, Ping
    JOURNAL OF THORACIC DISEASE, 2016, 8 (11) : 3087 - 3095
  • [10] Long-term outcome of minimally invasive mitral valve annuloplasty in disproportionate mitral regurgitation
    Albano, M.
    Nagumo, S.
    Vanderheyden, M.
    Bartunek, J.
    Collet, C.
    Balogh, Z.
    Katbeh, A.
    Kodeboina, M.
    Van Camp, G.
    Penicka, M.
    EUROPEAN HEART JOURNAL, 2020, 41 : 894 - 894