Dosimetric accuracy of a deterministic radiation transport based 192Ir brachytherapy treatment planning system. Part II: Monte Carlo and experimental verification of a multiple source dwell position plan employing a shielded applicator

被引:68
作者
Petrokokkinos, L. [1 ,2 ]
Zourari, K. [1 ]
Pantelis, E. [1 ]
Moutsatsos, A. [1 ]
Karaiskos, P. [1 ]
Sakelliou, L. [2 ]
Seimenis, I. [3 ]
Georgiou, E. [1 ]
Papagiannis, P. [1 ]
机构
[1] Univ Athens, Sch Med, Med Phys Lab, GR-11527 Athens, Greece
[2] Univ Athens, Dept Phys, Nucl & Particle Phys Sect, GR-15771 Athens, Greece
[3] Democritus Univ Thrace, Med Phys Lab, Sch Med, Alexandroupolis 68100, Greece
关键词
brachytherapy; Ir-192; treatment planning; Monte Carlo; polymer gel-MRI dosimetry; POLYMER GEL DOSIMETRY; DOSE VERIFICATION; UPDATE;
D O I
10.1118/1.3567507
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this work is the dosimetric validation of a deterministic radiation transport based treatment planning system (BRACHYVISION (TM) v. 8.8, referred to as TPS in the following) for multiple Ir-192 source dwell position brachytherapy applications employing a shielded applicator in homogeneous water geometries. Methods: TPS calculations for an irradiation plan employing seven VS2000 Ir-192 high dose rate (HDR) source dwell positions and a partially shielded applicator (GM11004380) were compared to corresponding Monte Carlo (MC) simulation results, as well as experimental results obtained using the VIP polymer gel-magnetic resonance imaging three-dimensional dosimetry method with a custom made phantom. Results: TPS and MC dose distributions were found in agreement which is mainly within +/- 2%. Considerable differences between TPS and MC results (greater than 2%) were observed at points in the penumbra of the shields (i.e.,close to the edges of the "shielded" segment of the geometries). These differences were experimentally verified and therefore attributed to the TPS. Apart from these regions, experimental and TPS dose distributions were found in agreement within 2 mm distance to agreement and 5% dose difference criteria. As shown in this work, these results mark a significant improvement relative to dosimetry algorithms that disregard the presence of the shielded applicator since the use of the latter leads to dosimetry errors on the order of 20%-30% at the edge of the "unshielded" segment of the geometry and even 2%-6% at points corresponding to the potential location of the target volume in clinical applications using the applicator (points in the unshielded segment at short distances from the applicator). Conclusions: Results of this work attest the capability of the TPS to accurately account for the scatter conditions and the increased attenuation involved in HDR brachytherapy applications employing multiple source dwell positions and partially shielded applicators. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3567507]
引用
收藏
页码:1981 / 1992
页数:12
相关论文
共 29 条
[1]   Monte Carlo dosimetry of a new 192Ir high dose rate brachytherapy source [J].
Angelopoulos, A ;
Baras, P ;
Sakelliou, L ;
Karaiskos, P ;
Sandilos, P .
MEDICAL PHYSICS, 2000, 27 (11) :2521-2527
[2]   Polymer gel dosimetry [J].
Baldock, C. ;
De Deene, Y. ;
Doran, S. ;
Ibbott, G. ;
Jirasek, A. ;
Lepage, M. ;
McAuley, K. B. ;
Oldham, M. ;
Schreiner, L. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (05) :R1-R63
[3]   RapidArc treatment verification in 3D using polymer gel dosimetry and Monte Carlo simulation [J].
Ceberg, Sofie ;
Gagne, Isabelle ;
Gustafsson, Helen ;
Scherman, Jonas Bengtsson ;
Korreman, Stine S. ;
Kjaer-Kristoffersen, Flemming ;
Hilts, Michelle ;
Back, Sven A. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (17) :4885-4898
[4]  
De Deene YH, 2001, PHYS MED BIOL, V46, P2801, DOI 10.1088/0031-9155/46/11/304
[5]   CT-based Monte Carlo simulation tool for dosimetry planning and analysis [J].
DeMarco, JJ ;
Solberg, TD ;
Smathers, JB .
MEDICAL PHYSICS, 1998, 25 (01) :1-11
[6]   CT-based dosimetry calculations for 125I prostate implants [J].
DeMarco, JJ ;
Smathers, JB ;
Burnison, CM ;
Ncube, QK ;
Solberg, TD .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (05) :1347-1353
[7]  
GLASGOW G P, 1979, Medical Physics (Woodbury), V6, P49, DOI 10.1118/1.594551
[8]   3D dose verification in 192Ir HDR prostate monotherapy using polymer gels and MRI [J].
Kipouros, P ;
Papagiannis, P ;
Sakelliou, L ;
Karaiskos, P ;
Sandilos, P ;
Baras, P ;
Seimenis, I ;
Kozicki, M ;
Anagnostopoulos, G ;
Baltas, D .
MEDICAL PHYSICS, 2003, 30 (08) :2031-2039
[9]   On the development of the VIPAR polymer gel dosimeter for three-dimensional dose measurements [J].
Kozicki, Marek ;
Maras, Piotr ;
Rybka, Krzysztof ;
Biegafiski, Tadeitsz ;
Kadlubowski, Slawomir ;
Petrokokkinos, Loukas .
MACROMOLECULAR SYMPOSIA, 2007, 254 :345-352
[10]   Evaluation of the gamma dose distribution comparison method [J].
Low, DA ;
Dempsey, JF .
MEDICAL PHYSICS, 2003, 30 (09) :2455-2464