Validation of a passive flux sampler for on-site measurement of formaldehyde emission rates from building and furnishing materials

被引:16
作者
Blondel, Alodie [1 ,2 ]
Plaisance, Herve [1 ,2 ]
机构
[1] Univ Lille Nord France, F-59000 Lille, France
[2] Ecole Mines Douai, Dept Chim & Environm, F-59508 Douai, France
关键词
CARBONYL-COMPOUNDS; INDOOR AIR; FIELD;
D O I
10.1039/c0ay00416b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A diffusive sampling device was developed for screening indoor sources of formaldehyde and determining the emission rates of these sources on-site. It consists of a glass Petri dish containing a quartz filter coated with 2,4-dinitrophenylhydrazine (DNPH) which is placed on the tested material for sampling. Formaldehyde emitted from the material diffuses through the air column inside the sampler and is collected onto the DNPH filter. The formaldehyde emission rate is determined from the mass collected by the sampler. The dependence of the sampled formaldehyde amount on the diffusion length inside the sampler was examined and led us to select a length of 20 mm for which the diffusion in the air layer controls the mass transfer from the material to the sampling surface (filter). A linear relationship with a high correlation (r(2) = 0.97) was obtained between the mass collected by the passive flux sampler and the emission rates measured by a standard chamber method, analysing a large series of indoor materials with the two methods in parallel. Neither the sampling time (ranging from 4 to 8 h) nor the temperature (from 23 to 35 degrees C) was observed to influence the sampler performance. Furthermore, the detection limit attained 1.2 mu g m(-2) h(-1) for a 6h-sampling time and a satisfying precision of replicate measurements (relative standard deviation of 7.8% on average) is adequate for monitoring the emission rates of primary sources contributing to formaldehyde indoor concentrations.
引用
收藏
页码:2032 / 2038
页数:7
相关论文
共 19 条
[11]   Solid phase microextraction sampling for a rapid and simple on-site evaluation of volatile organic compounds emitted from building materials [J].
Nicolle, Jerome ;
Desauziers, Valerie ;
Mocho, Pierre .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1208 (1-2) :10-15
[12]  
*OQAI, 2006, OBS QUAL AIR INT CAM, P183
[13]   Passive emission colorimetric sensor (PECS) for measuring emission rates of formaldehyde based on an enzymatic reaction and reflectance photometry [J].
Shinohara, Naohide ;
Kajiwara, Tomohisa ;
Ohnishi, Masato ;
Kodama, Kenichi ;
Yanagisawa, Yukio .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2008, 42 (12) :4472-4477
[14]   Passive flux sampler for measurement of formaldehyde emission rates [J].
Shinohara, Naohide ;
Fujii, Minoru ;
Yamasaki, Akihiro ;
Yanagisawa, Yukio .
ATMOSPHERIC ENVIRONMENT, 2007, 41 (19) :4018-4028
[15]   Characterization of the Field and Laboratory Emission Cell - FLEC: Flow field and air velocities [J].
Uhde, E ;
Borgschulte, A ;
Salthammer, T .
ATMOSPHERIC ENVIRONMENT, 1998, 32 (04) :773-781
[16]   A simple method for screening emission sources of carbonyl compounds in indoor air [J].
Yamashita, Shohei ;
Kume, Kazunari ;
Horiike, Toshiyuki ;
Honma, Nobuyuki ;
Fusaya, Masahiro ;
Ohura, Takeshi ;
Amagai, Takashi .
JOURNAL OF HAZARDOUS MATERIALS, 2010, 178 (1-3) :370-376
[17]   Indoor air quality investigation according to age of the school buildings in Korea [J].
Yang, Wonho ;
Sohn, Jongryeul ;
Kim, Jihwan ;
Son, Busoon ;
Park, Jinchul .
JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2009, 90 (01) :348-354
[18]  
Zhang JSS, 1995, ASHRAE TRAN, V101, P116
[19]   APPARENT PARTITION-COEFFICIENTS OF 15 CARBONYL-COMPOUNDS BETWEEN AIR AND SEAWATER AND BETWEEN AIR AND FRESH-WATER - IMPLICATIONS FOR AIR SEA EXCHANGE [J].
ZHOU, XL ;
MOPPER, K .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1990, 24 (12) :1864-1869