Can anaesthetists be taught to interpret the effects of general anaesthesia on the electroencephalogram? Comparison of performance with the BIS and spectral entropy

被引:41
作者
Barnard, J. P. [1 ]
Bennett, C. [1 ]
Voss, L. J. [1 ]
Sleigh, J. W. [1 ]
机构
[1] Waikato Hosp, Dept Anaesthesia, Hamilton, New Zealand
关键词
entropy; monitoring; bispectral index; electroencephalogram;
D O I
10.1093/bja/aem198
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Unlike the other physiological waveforms monitored in anaesthesia, the EEG lacks a regularly repeating pattern, implying that it would be very difficult for an anaesthetist to obtain any useful information from the raw EEG. There are, however, clear changes in the EEG caused by GABA-ergic anaesthetic agents. The anaesthetized EEG still looks like a random waveform, but clearly a different random waveform from that seen when conscious. Methods. The aim of this study was to assess how 40 anaesthetists would perform at interpreting intra-operative EEGs compared with two processed EEG (pEEG) monitors, BIS and entropy, after a short educational presentation. Short segments of EEGs were used from the pre-induction phase, the intra-operative phase with adequate surgical anaesthesia, and the transition phase between these two states. Results. While anaesthetists' performance varied widely, most could reliably differentiate an anaesthetized from a conscious EEG. Further, both humans (41% wrong) and machines (30% wrong) made mistakes. Unlike the anaesthetists, the pEEG monitors did not make a major error (i.e. producing a number in the conscious range (> 85) when analysing an anaesthetized EEG or the converse error). Conclusion. A brief PowerPoint presentation enables anaesthetists to recognize the effects on the EEG of GABA-ergic anaesthetic agents. In the clinical context, it remains likely that the combination of a pEEG monitor that clearly presents the EEG and a clinician who has a good, basic understanding of, and a willingness to look at, the raw EEG will result in more accurate interpretation of the intra-operative EEG.
引用
收藏
页码:532 / 537
页数:6
相关论文
共 21 条
[1]   Entropy during propofol hypnosis, including an episode of wakefulness [J].
Anderson, RE ;
Barr, G ;
Öwall, A ;
Jakobsson, J .
ANAESTHESIA, 2004, 59 (01) :52-56
[2]   Electroencephalographic indices related to hypnosis and amnesia during propofol anaesthesia for cardioversion [J].
Baker, GW ;
Sleigh, JW ;
Smith, P .
ANAESTHESIA AND INTENSIVE CARE, 2000, 28 (04) :386-391
[3]   Comparison of electrophysiologic monitors with clinical assessment of level of sedation [J].
Chisholm, CJ ;
Zurica, J ;
Mironov, D ;
Sciacca, RR ;
Ornstein, E ;
Heyer, EJ .
MAYO CLINIC PROCEEDINGS, 2006, 81 (01) :46-52
[4]   Spectral entropy and bispectral index as measures of the electroencephalographic effects of propofol [J].
Ellerkmann, RK ;
Soehle, M ;
Alves, TM ;
Liermann, VM ;
Wenningmann, I ;
Roepcke, H ;
Kreuer, S ;
Hoeft, A ;
Bruhn, J .
ANESTHESIA AND ANALGESIA, 2006, 102 (05) :1456-1462
[5]  
Ellerkmann RK, 2004, ANESTHESIOLOGY, V101, P1275
[6]   Bispectral index monitoring allows faster emergence and improved recovery from propofol, alfentanil, and nitrous oxide anesthesia [J].
Gan, TJ ;
Glass, PS ;
Windsor, A ;
Payne, F ;
Rosow, C ;
Sebel, P ;
Manberg, P ;
Howell, S ;
Sanderson, I ;
Ray, J ;
Elidrissi, C ;
Wilkes, N ;
Calhoun, P ;
Connors, P ;
Alfille, P ;
Shapiro, L ;
Denman, W ;
Dershwitz, M ;
Clifford, J ;
Embree, P ;
Sigl, J .
ANESTHESIOLOGY, 1997, 87 (04) :808-815
[7]   Effect on the electro-encephalogram of certain drugs which influence nervous activity [J].
Gibbs, FA ;
Gibbs, EL ;
Lennox, WG .
ARCHIVES OF INTERNAL MEDICINE, 1937, 60 (01) :154-166
[8]   Bispectral index monitoring during electroconvulsive therapy under propofol anaesthesia [J].
Gunawardane, PO ;
Murphy, PA ;
Sleigh, JW .
BRITISH JOURNAL OF ANAESTHESIA, 2002, 88 (02) :184-187
[9]  
Hirota K, 1999, EUR J ANAESTH, V16, P779
[10]   Propofol effective concentration 50 and its relationship to bispectral index [J].
Irwin, MG ;
Hui, TWC ;
Milne, SE ;
Kenny, GNC .
ANAESTHESIA, 2002, 57 (03) :242-248