Noninvasive Glucose Measurement by Microwave Biosensor with Accuracy Enhancement

被引:3
作者
Zhang, Ruochong [1 ]
Qu, Zilian [1 ]
Jin, Haoran [1 ]
Liu, Siyu [1 ]
Luo, Yunqi [1 ]
Zheng, Yuanjin [1 ]
机构
[1] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore, Singapore
来源
2018 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS) | 2018年
关键词
noninvasive glucose sensor; microwave; reflected S-parameter S-11; resonance frequency; data fusion; BLOOD-GLUCOSE;
D O I
10.1109/ISCAS.2018.8351711
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A novel noninvasive microwave biosensor for glucose measurement was designed, developed and tested to show its potential for real-time and continuous glucose monitoring. The reflected S-parameter S-11 was investigated with different glucose concentrations within the range of 0.5 similar to 7 g/dL. The magnitude and resonance frequency information were utilized for prediction and then combined by data fusion to enhance the accuracy. The prediction results by magnitude and resonance frequency of S-11 versus reference glucose concentration show root-mean-squared errors (RMSE) of 0.2887 g/dL and 0.1681 g/dL respectively. The prediction by data fusion shows RMSE value of 0.1364 g/dL indicating significant accuracy improvement of 52.75% and 18.86% compared to single parameter based magnitude and frequency predictions.
引用
收藏
页数:4
相关论文
共 24 条
[1]   Positioning and levitation media for the separation of biological cells [J].
Arnold, WM .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2001, 37 (05) :1468-1475
[2]   Sodium chloride sensing by using a near-field microwave microprobe [J].
Babajanyan, Arsen ;
Kim, Jongchul ;
Kim, Songhui ;
Lee, Kiejin ;
Friedman, Barry .
APPLIED PHYSICS LETTERS, 2006, 89 (18)
[3]   A Novel Microwave Sensor to Detect Specific Biomarkers in Human Cerebrospinal Fluid and Their Relationship to Cellular Ischemia During Thoracoabdominal Aortic Aneurysm Repair [J].
Fok, M. ;
Bashir, M. ;
Fraser, H. ;
Strouther, N. ;
Mason, A. .
JOURNAL OF MEDICAL SYSTEMS, 2015, 39 (04)
[4]  
Harman-Boehm Ilana, 2009, J Diabetes Sci Technol, V3, P253
[5]   Self-monitoring of blood glucose - Language and financial barriers in a managed care population with diabetes [J].
Karter, AJ ;
Ferrara, A ;
Darbinian, JA ;
Ackerson, LM ;
Selby, JV .
DIABETES CARE, 2000, 23 (04) :477-483
[6]   Microwave dielectric resonator biosensor for aqueous glucose solution [J].
Kim, Jongchul ;
Babajanyan, Arsen ;
Hovsepyan, Artur ;
Lee, Kiejin ;
Friedman, Barry .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (08)
[7]   A reusable robust radio frequency biosensor using microwave resonator by integrated passive device technology for quantitative detection of glucose level [J].
Kim, N. Y. ;
Dhakal, R. ;
Adhikari, K. K. ;
Kim, E. S. ;
Wang, C. .
BIOSENSORS & BIOELECTRONICS, 2015, 67 :687-693
[8]   Noninvasive in vitro measurement of pig-blood D-glucose by using a microwave cavity sensor [J].
Kim, Seungwan ;
Melikyan, Harutyun ;
Kim, Jongchel ;
Babajanyan, Arsen ;
Lee, Jung-Ha ;
Enkhtur, Lkhamsuren ;
Friedman, Barry ;
Lee, Kiejin .
DIABETES RESEARCH AND CLINICAL PRACTICE, 2012, 96 (03) :379-384
[9]   Transdermal monitoring of glucose and other analytes using ultrasound [J].
Kost, Joseph ;
Mitragotri, Samir ;
Gabbay, Robert A. ;
Pishko, Michael ;
Langer, Robert .
NATURE MEDICINE, 2000, 6 (03) :347-350
[10]   Magnetic permeability measurements in bioanalysis and biosensors [J].
Kriz, CB ;
Radevik, K ;
Kriz, D .
ANALYTICAL CHEMISTRY, 1996, 68 (11) :1966-1970