Determination of the optimal location of samples on quartz tuning fork-based biosensors: a computational study

被引:2
作者
Atabaki, Amir Hossein [1 ]
Montazeri, Abbas [2 ,3 ]
Rafii-Tabar, Hashem [1 ,4 ]
Sasanpour, Pezhman [1 ,3 ]
机构
[1] Shahid Beheshti Univ Med Sci, Sch Med, Dept Med Phys & Biomed Engn, Tehran, Iran
[2] KN Toosi Univ Technol, Fac Mat Sci & Engn, Computat Nanomat Lab CNL, Tehran, Iran
[3] Inst Res Fundamental Sci, Sch Nano Sci, IPM, POB 19395-5531, Tehran, Iran
[4] Iran Acad Sci, Phys Branch, Tehran, Iran
关键词
quartz tuning fork; biosensor; resonance frequency; finite element method; QTF; COMSOL; vibration; CARDIAC TROPONIN-I; TEMPERATURE; DIAGNOSIS; CRYSTAL;
D O I
10.1088/2057-1976/ac26a5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In view of efficiency, simple operation, and affordable cost and disposability, quartz tuning fork systems form good candidates for mechanical-based biosensors in point of care applications. Based on the geometrical structure, the frequency response of the tuning fork- based sensors is dependent on the location of absorbed samples. In order to have the maximum efficiency and sensitivity, the optimized condition of sample loading on the fork structures should be considered. In this regard, here, we have determined the optimized sample location to be on the prongs of the quartz tuning fork by calculating the frequency response of the quartz tuning fork using the finite element method. From an application point of view, we have obtained an agreement between the calculational method and the experimental excitation technique of the structure. The results from our study show that by using an appropriate location for the sample, the quartz tuning fork could be exploited with high sensitivity.
引用
收藏
页数:8
相关论文
共 37 条
[1]   Hospital Arrival Rate within Golden Time and Factors Influencing Prehospital Delays among Patients with Acute Myocardial Infarction [J].
Ahn, Hye Mi ;
Kim, Hyeongsu ;
Lee, Kun Sei ;
Lee, Jung Hyun ;
Jeong, Hyo Seon ;
Chang, Soung Hoon ;
Lee, Kyeong Ryong ;
Kim, Sung Hea ;
Shin, Eun Young .
JOURNAL OF KOREAN ACADEMY OF NURSING, 2016, 46 (06) :804-812
[2]  
Aloveko M., 2019, APPL PHYS LETT, V115, DOI [10.1063/1.5124736, DOI 10.1063/1.5124736]
[3]  
Aly AH, 2021, MATER RES-IBERO-AM J, V24, DOI [10.1590/1980-5373-mr-2020-0483, 10.1590/1980-5373-MR-2020-0483]
[4]   Comparative advantages of mechanical biosensors [J].
Arlett, J. L. ;
Myers, E. B. ;
Roukes, M. L. .
NATURE NANOTECHNOLOGY, 2011, 6 (04) :203-215
[5]   Field-Effect Transistor-Integration with TiO2 Nanoparticles for Sensing of Cardiac Troponin I Biomarker [J].
Arshad, M. K. Md ;
Adzhri, R. ;
Fathil, M. F. M. ;
Gopinath, Subash C. B. ;
Nuzaihan, M. M. N. .
JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2018, 18 (08) :5283-5291
[6]  
Banerjee I., 2018, FRUGAL INNOVATION BI, P22, DOI [10.1007/978-3-319-66647-1_2, DOI 10.1007/978-3-319-66647-1_2]
[7]   Micro/Nano fabricated cantilever based biosensor platform: A review and recent progress [J].
Basu, Aviru Kumar ;
Basu, Adreeja ;
Bhattacharya, Shantanu .
ENZYME AND MICROBIAL TECHNOLOGY, 2020, 139
[8]   Lab-on-a-Chip for Cardiovascular Physiology and Pathology [J].
Beverung, Sean ;
Wu, Jingwen ;
Steward, Robert, Jr. .
MICROMACHINES, 2020, 11 (10)
[9]   Rapid and Sensitive Detection of Cardiac Troponin I for Point-of-Care Tests Based on Red Fluorescent Microspheres [J].
Cai, Yanxue ;
Kang, Keren ;
Li, Qianru ;
Wang, Yu ;
He, Xiaowei .
MOLECULES, 2018, 23 (05)
[10]   Quartz crystal microbalance: Sensing cell-substrate adhesion and beyond [J].
Chen, Jennifer Y. ;
Penn, Lynn S. ;
Xi, Jun .
BIOSENSORS & BIOELECTRONICS, 2018, 99 :593-602