Pulse power measurements and attenuator characterization of the hard X-ray beamline at the Linac Coherent Light Source

被引:0
|
作者
Song, Sanghoon [1 ]
Alonso-Mori, Roberto [1 ]
Chollet, Matthieu [1 ]
Feng, Yiping [1 ]
Glownia, James M. [1 ]
Lemke, Henrik T. [1 ]
Sikorski, Marcin [1 ]
Zhu, Diling [1 ]
Moeller, Stefan [1 ]
Lee, Hae Ja [1 ]
Hunter, Mark S. [1 ]
Carini, Gabriella [2 ]
Tiedtke, Kai [3 ]
Jastrow, Ulf [3 ]
Sorokin, Andrey [3 ]
Richter, Mathias [4 ]
Owada, Shigeki [5 ]
Tono, Kensuke [5 ,6 ]
Saito, Norio [5 ,7 ]
Tanaka, Takahiro [5 ,7 ]
Kato, Masahiro [5 ,7 ]
Yabashi, Makina [5 ,6 ]
Robert, Aymeric [1 ]
机构
[1] SLAC Natl Accelerator Lab, Linac Coherent Light Source, 2575 Sand Hill Rd, Menlo Pk, CA 94025 USA
[2] Brookhaven Natl Lab, Upton, NY 11973 USA
[3] DESY, Notkestr 85, D-22607 Hamburg, Germany
[4] Phys Tech Bundesanstalt, Abbestr 2-12, D-10587 Berlin, Germany
[5] RIKEN, SPring 8 Ctr, 1-1-1 Kouto, Sayo, Hyogo 6795198, Japan
[6] Japan Synchrotron Radiat Res Inst, 1-1-1 Kouto, Sayo, Hyogo 6795198, Japan
[7] Natl Inst Adv Ind Sci & Technol, NMIJ, Tsukuba, Ibaraki 3058568, Japan
来源
X-RAY FREE-ELECTRON LASERS: ADVANCES IN SOURCE DEVELOPMENT AND INSTRUMENTATION V | 2019年 / 11038卷
关键词
XFEL; Hard X-ray; Intensity monitor; optical laser power meter;
D O I
10.1117/12.2520827
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The absolute power of the Linac Coherent Light Source pulses has been measured accurately in the hard X-ray beamline by using simultaneously two detectors:(1) an X-ray Gas Monitor Detector (XGMD)(2) in tandem with a radiometer.(3) From these measurements, we were also able to characterize and calibrate in details our sets of beamline attenuators, in addition to extending an absolute calibration for our beamline intensity monitors. Similarly, we demonstrate that commercial optical power meter has a response in the hard X-ray regime, that can be cross-correlated with the absolute power of the LCLS beam.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Radiation properties of the Linac Coherent Light Source: Challenges for x-ray optics
    Arthur, J
    Tatchyn, R
    X-RAY FEL OPTICS AND INSTRUMENTATION, 2001, 4143 : 1 - 8
  • [22] X-ray optics and diagnostics for the first experiments on the Linac Coherent Light Source
    Wootton, A
    Arthur, J
    Barbee, T
    Bionta, R
    London, R
    Park, HS
    Ryutov, D
    Spiller, E
    Tatchyn, R
    OPTICS FOR FOURTH-GENERATION X-RAY SOURCES, 2001, 4500 : 113 - 122
  • [23] Coherent Bragg nanodiffraction at the hard X-ray Nanoprobe beamline
    Hruszkewycz, S. O.
    Holt, M. V.
    Maser, J.
    Murray, C. E.
    Highland, M. J.
    Folkman, C. M.
    Fuoss, P. H.
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2014, 372 (2010):
  • [24] Single Shot Spatial and Temporal Coherence Properties of the SLAC Linac Coherent Light Source in the Hard X-Ray Regime
    Gutt, C.
    Wochner, P.
    Fischer, B.
    Conrad, H.
    Castro-Colin, M.
    Lee, S.
    Lehmkuehler, F.
    Steinke, I.
    Sprung, M.
    Roseker, W.
    Zhu, D.
    Lemke, H.
    Bogle, S.
    Fuoss, P. H.
    Stephenson, G. B.
    Cammarata, M.
    Fritz, D. M.
    Robert, A.
    Gruebel, G.
    PHYSICAL REVIEW LETTERS, 2012, 108 (02)
  • [25] Absolute pulse energy measurements of soft x-rays at the Linac Coherent Light Source
    Tiedtke, K.
    Sorokin, A. A.
    Jastrow, U.
    Juranic, P.
    Kreis, S.
    Gerken, N.
    Richter, M.
    Arp, U.
    Feng, Y.
    Nordlund, D.
    Soufli, R.
    Fernandez-Perea, M.
    Juha, L.
    Heimann, P.
    Nagler, B.
    Lee, H. J.
    Mack, S.
    Cammarata, M.
    Krupin, O.
    Messerschmidt, M.
    Holmes, M.
    Rowen, M.
    Schlotter, W.
    Moeller, S.
    Turner, J. J.
    OPTICS EXPRESS, 2014, 22 (18): : 21214 - 21226
  • [26] Predicting the coherent X-ray wavefront focal properties at the Linac Coherent Light Source (LCLS) X-ray free electron laser
    Barty, Anton
    Soufli, Regina
    McCarville, Tom
    Baker, Sherry L.
    Pivovaroff, Michael J.
    Stefan, Peter
    Bionta, Richard
    OPTICS EXPRESS, 2009, 17 (18): : 15508 - 15519
  • [27] The Coherent X-ray Scattering Beamline at Taiwan Photon Source
    Lin, J.
    Huang, Y.
    Chen, C.
    Jeng, U.
    Mou, C.
    Lin, T.
    Chen, H.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2014, 70 : C1747 - C1747
  • [28] Research and development for X-ray optics and diagnostics on the linac coherent light source (LCLS)
    Wootton, A
    Arthur, J
    Barbee, T
    Bionta, R
    Jankowski, A
    London, R
    Ryutov, D
    Shepherd, R
    Shlyaptsev, V
    Tatchyn, R
    Toor, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 483 (1-2): : 345 - 350
  • [29] Soft x-ray seeding studies for the SLAC Linac Coherent Light Source II
    Hemsing, E.
    Marcus, G.
    Fawley, W. M.
    Schoenlein, R. W.
    Coffee, R.
    Dakovski, G.
    Hastings, J.
    Huang, Z.
    Ratner, D.
    Raubenheimer, T.
    Penn, G.
    PHYSICAL REVIEW ACCELERATORS AND BEAMS, 2019, 22 (11):
  • [30] The X-ray diagnostic beamline at the Canadian Light Source
    Bergstrom, John C.
    Vogt, Johannes M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 587 (2-3): : 441 - 457