摘要
In k-t BLAST and k-t SENSE, data acquisition is accelerated by sparsely sampling k-space over time. This undersampling in k-t space causes the object signals to be convolved with a point spread function in x-f space (x = spatial position, f = temporal frequency). The resulting aliasing is resolved by exploiting spatiotemporal correlations within the data. In general, reconstruction accuracy can be improved by controlling the k-t sampling pattern to minimize signal overlap in x-f space. In this work, we describe an approach to obtain generally favorable patterns for typical image series without specific knowledge of the image series itself. These optimized sampling patterns were applied to free-breathing, untriggered (i.e., real-time) cardiac imaging with steady-state free precession (SSFP). Eddy-current artifacts, which are otherwise increased drastically in SSFP by the undersampling, were minimized using alternating k-space sweeps. With the synergistic combination of the k-t approach with optimized sampling and SSFP with alternating k-space sweeps, it was possible to achieve a high signal-to-noise ratio, high contrast, and high spatiotemporal resolutions, while achieving substantial immunity against eddy currents. Cardiac images are shown, demonstrating excellent image quality and an in-plane resolution of similar to 2.0 mm at > 25 frames/s, using one or more receiver coils. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:1372 / 1382
页数:11
相关论文
共 22 条
[1]  
CONWAY JH, 1999, SPHERE PACKING LATTI
[2]   BLOCK REGIONAL INTERPOLATION SCHEME FOR K-SPACE (BRISK) - A RAPID CARDIAC IMAGING TECHNIQUE [J].
DOYLE, M ;
WALSH, EG ;
BLACKWELL, GG ;
POHOST, GM .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (02) :163-170
[3]   SPIN WARP NMR IMAGING AND APPLICATIONS TO HUMAN WHOLE-BODY IMAGING [J].
EDELSTEIN, WA ;
HUTCHISON, JMS ;
JOHNSON, G ;
REDPATH, T .
PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04) :751-756
[4]   THE INFORMATION-CONTENT OF MR IMAGES [J].
FUDERER, M .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (04) :368-380
[5]   FLASH IMAGING - RAPID NMR IMAGING USING LOW FLIP-ANGLE PULSES [J].
HAASE, A ;
FRAHM, J ;
MATTHAEI, D ;
HANICKE, W ;
MERBOLDT, KD .
JOURNAL OF MAGNETIC RESONANCE, 1986, 67 (02) :258-266
[6]   On the influence of training data quality in k-t BLAST reconstruction [J].
Hansen, MS ;
Kozerke, S ;
Pruessmann, KP ;
Boesiger, P ;
Pedersen, EM ;
Tsao, J .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (05) :1175-1183
[7]   Single-breathhold 3D-TrueFISP cine cardiac imaging [J].
Jung, BA ;
Hennig, J ;
Scheffler, K .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (05) :921-925
[8]   Adaptive sensitivity encoding incorporating temporal filtering (TSENSE) [J].
Kellman, P ;
Epstein, FH ;
McVeigh, ER .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (05) :846-852
[9]   Accelerating cardiac Cine 3D Imaging using k-t BLAST [J].
Kozerke, S ;
Tsao, J ;
Razavi, R ;
Boesiger, P .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (01) :19-26
[10]  
Madore B, 1999, MAGNET RESON MED, V42, P813, DOI 10.1002/(SICI)1522-2594(199911)42:5<813::AID-MRM1>3.0.CO